Safety Precautions

Milesight will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide.

  • The device must not be modified in any way.
  • Do not place the device close to objects with naked flames.
  • Do not place the device where the temperature is below/above the operating range.
  • Do not power on the device or connect it to other electrical device when installing.
  • Check lightning and water protection when used outdoors.
  • Do not connect or power the equipment using cables that have been damaged.

Related Documents
This Start Guide only explains the installation of Milesight UR35 router. For more functionality and advanced settings, please refer to the relevant documents as below.

Document Description
UR35 Datasheet Datasheet for UR35 industrial cellular router.
UR35 User Guide Users could refer to the guide for instruction on how to log

in the web GUI, and how to configure all the settings.

The related documents are available on Milesight website: https://www .milesight-iot.com

Declaration of Conformity
UR35 are in conformity with the essential requirements and other relevant provisions of the CE, FCC, and RoHS.RG2I UR35 Industrial Router Pro Series -
icon 1

© 2011-2022 Xiamen Milesight IoT Co., Ltd.
All rights reserved.
All information in this guide is protected by copyright law. Whereby, no organization or individual shall copy or reproduce the whole or part of this user guide by any means  without written authorization from Xiamen Milesight IoT Co., Ltd.RG2I UR35 Industrial Router Pro Series - Figure
1

For assistance, please contact
Milesight technical support:
Email: iot.support@milesight.com
Tel: 86-592-5085280
Fax: 86-592-5023065
Address: Building C09, Software Park III, Xiamen 361024, China

Revision History

Date Doc Version Description
Aug. 1, 2019 V 1.0 Initial version
Feb. 11, 2020 V 1.1 1. Replace serial port picture;

2. Delete reboot descriptions of reset button
Aug. 26, 2020| V 1.2| 1. Web GUI change;
2. 2.Add -485 model
Nov. 20, 2020| V 2.0| Layout replace
Dec. 1, 2021| V 2.1| Update cellular pictures
8-Jun-22| V 2.2| 1. Wall mounting bracket customizable
2. Web GUI logo update

Packing List

Before you begin to install the UR35 router, please check the package contents to verify that you have received the items below.

RG2I UR35 Industrial Router Pro Series - Figure 2

If any of the above items is missing or damaged, please contact your sales representative.

Hardware Introduction

2.1 Overview
A. Front Panel

RG2I UR35 Industrial Router Pro Series - Figure 3

  1. Wi-Fi Antenna Connector

  2. AUX Antenna Cellular Connector

  3. GPS Antenna Connector

  4. MAIN Cellular Antenna Connector

  5. LED Indicator Area
    POWER: Power Indicator
    SYSTEM: Status Indicator
    Wi-Fi: Wi-Fi Indicator
    VPN: VPN Indicator
    SIM : SIM Status Indicator
    : Signal Strength Indicator

  6. Ethernet Port & Indicator
    B. Left Side Panel
    RG2I UR35 Industrial Router Pro Series - Figure 4
    7 Grounding Stud
    8 SIM and Reset Button Holder
    9 Power Connector
    10 Serial Port & I/O

2.2 Dimensions (mm)

RG2I UR35 Industrial Router Pro Series - Figure 5

2.3 Serial & IO & Power Pinouts

P I N| R S 232| R S 485| D I| D O|

D e s c r i p t i o n

---|---|---|---|---|---
1| —| —| IN| —| Digital Input
2| GND| —| GND| —| Ground
3| —| B| —| —| Data –
4| TXD| —| —| —| Transmit Data
5| —| —| —| COM| Common Ground
6| —| —| —| OUT| Digital Output
7| —| A| —| —| Data +
8| RXD| —| —| —| Receive Data

N o t e : For -RS485 model, RXD—>A, TXD—>B.

P I N| D e s c r i p t i o n|

Wire C o l o r

---|---|---
9| Positive| Red
10| Negative| Black

2.4 LED Indicators

L E D

| I n d i c a t i o n| S t a t u s|

D e s c r i p t i o n

---|---|---|---
POWER| Power Status| Off| The power is switched off
On| The power is switched on
SYSTEM| System Status| Green Light| Static: Start-up
Blinking slowly: the system is running properly
Red Light| The system goes wrong
VPN| VPN Status| Off| VPN is disconnected
Green Light| VPN is connected
Wi-Fi| Wi-Fi Status| Off| Wi-Fi is disabled
Green Light| Static: Wi-Fi is enabled
Blinking slowly: sending or receiving data via Wi-Fi
SIM| SIM Card Status| Off| SIM1 or SIM2 is registering or fails to register (or there are no SIM cards inserted)
Green Light| Blinking  slowly:  SIM1  (as  primary   SIM)  has  been registered and is ready for dial-up
Blinking  rapidly:   SIM1(as  primary   SIM)  has  been registered and is dialing up now
Static: SIM1 (as primary SIM) has been  registered and dialed up successfully
Orange Light| Blinking  slowly:  SIM2  (as  primary   SIM)  has  been registered and is ready for dial-up
Blinking  rapidly:   SIM2  (as  primary   SIM)  has  been
| | registered and is dialing up now
---|---|---
| | Static: SIM2 (as primary SIM) has been  registered and dialed up successfully
| Signal 1/2/3| Off| No signal

Signal

| Green Light| Static/Off/Off:  weak signals  with  1-10  ASU  (please check if the antenna is installed correctly, or move  the antenna to a suitable location to get better signal)
Strength| Static/Static/Off:   normal| signals  with   11-20    ASU
| (average signal strength)|
| Static/Static/Static:   strong   signals  with   21-31   ASU (signal is good)

2.5 Reset Button
Reset button is under the SIM slots.

F un c t i o n

| D e s c r i p t i o n
---|---
S YSTEM L E D| A c t i o n
Reset| Blinking| Press and hold the reset button for more than 5 seconds.
Static Green → Rapidly Blinking| Release the button and wait.
Off → Blinking| The router is now reset to factory defaults.

2.6 Ethernet Port Indicator

I n d i c a t o r| S t a t u s| D e s c r i p t i o n
---|---|---
Link Indicator (Orange)| On| Connected
Blinking| Transmitting data
Off| Disconnected

Hardware Installation

Environmental Requirements

  • Power Input: 9-48 VDC (48 VDC is needed for PoE output)
  • Power Consumption: Typical 3.9 W (Max 4.6 W)
  • Operating Temperature: -40°C to 70°C (-40°F -158°F)
  • Relative Humidity: 0% to 95% (non-condensing) at 25°C/77°F

3.1 SIM Card/Micro SD Card Installation
UR35 do not support hot-plug. Please cut off the power before insert or take off cards.

A. Unscrew the cover of the SIM card then take it off.

B. Put SIM card/Micro SD into the slot and screw it up.RG2I UR35 Industrial
Router Pro Series - Figure 9

3.2 Antenna Installation
Rotate the antenna into the antenna connector accordingly. The external antenna should be installed vertically always on a site with a good signal.RG2I UR35 Industrial Router Pro Series - Figure
10

3.3 Router Installation
The router can be placed on a desktop or mounted to a wall or a DIN rail.
3.3.1 DIN Rail Mounting (Measured in mm)
Use 2 pcs of M3 × 6 flat head Phillips screws to fix the mount clip to the router, and then hang the device to the DIN rail. The width of DIN rail is 3.5cm.
Recommended torque for mounting is 1.0 N·m, and the maximum allowed is 1.2 N·m.RG2I UR35 Industrial Router Pro Series - Figure 11

3.3.2 Wall Mounting (Measured in mm)
Use 2 pcs of M3 × 6 flat head Phillips screws to fix the wall mounting bracket to the router, and then use 2 pcs of M3 drywall screws to mount the router associated with the  wall plugs on the wall.
Recommended torque for mounting is 1.0 N·m, and the maximum allowed is 1.2 N·m.RG2I UR35 Industrial Router Pro Series - Figure 12

3.4 Protective Grounding Installation
Remove the grounding nut, then connect the grounding ring of the cabinet’s grounding wire onto the grounding stud and screw up the grounding nut.a

The router must be grounded when deployed. According to operating environment, the ground wire should be connected with grounding stud of router.

Log in the Web GUI of Router

Please connect PC to LAN port of UR35 router. PC can obtain an IP address, or you can configure a static IP address manually. The following steps are based on Windows  10 operating system for your reference.
IP Address: 192.168.1.1
Username: admin
Password: password
A. Go to “Control Panel” → “Network and Internet” → “Network and Sharing Center”, then click “Ethernet” (May have different names).RG2I UR35
Industrial Router Pro Series - Figure 14

B. Go to “Properties” → “Internet Protocol Version 4(TCP/IPv4) ”, select “Obtain an IP address automatically” or “Use the following IP address”, then assign a static IP  manually within the same subnet of the device.RG2I UR35
Industrial Router Pro Series - Figure 15

C. Open a Web browser on your PC (Chrome is recommended), type in the IP address 192.168.1.1, and press Enter on your keyboard.
D. Enter the username, password, and click “Login”.RG2I UR35 Industrial
Router Pro Series - Figure 16

If you enter the username or password incorrectly more than 5 times, the login page will be locked for 10 minutes.
E. When you login with the default username and password, you will be asked to modify the password.
It’s suggested that you change the password for the sake of security. Click “Cancel” button if you want to modify it later.RG2I UR35 Industrial Router
Pro Series - Figure 17

F. After you login the Web GUI, you can view system information and perform configuration on the router.RG2I UR35 Industrial Router Pro Series - Figure
18

Network Configuration

This chapter explains how to connect UR35 to network via WAN connection or cellular.
5.1 Ethernet WAN Configuration
A. Go to “Network” → “Interface” → “WAN” to select connection type and configure WAN parameters, click “Save & Apply” button to make the changes take effect.RG2I UR35 Industrial Router Pro Series - Figure
19

B. Connect WAN port to another network devices like modem.
C. Go to “Network” → “Interface” → “Link Failover” to rise the WAN priority to

  1. D. Open your preferred browser on PC, then type any available web address into address bar and see if it is able to visit Internet via UR35 router.RG2I
UR35 Industrial Router Pro Series - Figure 20

5.2 Cellular Connection Configuration
Take inserting SIM card into SIM1 slot as an example; please refer to the following detailed operations.
A. Go to “Network” → “Interface” → “Cellular” → “Cellular Setting” to configure APN, PIN code or other cellular info, click “Save” and “Apply” to save the configuration.
RG2I UR35 Industrial Router Pro Series - Figure 21

B. Go to “Network” → “Interface” → “Link Failover” to enable SIM1 and rise link priority of SIM1.RG2I UR35 Industrial Router Pro Series - Figure
22

C. Click to configure ICMP ping detection information. RG2I UR35 Industrial
Router Pro Series - Figure 23

D. Click “Status” → “Cellular” to view the status of the cellular connection. If it shows “Connected”, it means SIM1 has dialed up successfully. On the other hand, you can  check the status of SIM indicator. If it keeps on green light statically, it means SIM1 has dialed up successfully.RG2I UR35
Industrial Router Pro Series - Figure 24

E. Open your preferred browser on PC, then type any available web address into address bar and see if it is able to visit Internet via UR35 router.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals