RG2I WS101 Smart Button Featuring LoRaWAN User Guide
- June 9, 2024
- RG2i
Table of Contents
RG2I WS101 Smart Button Featuring LoRaWAN
Safety Precautions
Milesight will not shoulder responsibility for any loss or damage resulting from not following the instructions of this operating guide.
- The device must not be modified in any way.
- In order to protect the security of the device, please change device the password when first configured. The default password is 123456.
- Do not place the device close to objects with naked flames.
- Do not place the device where the temperature is below/above the operating range.
- When installing the battery, please install it accurately, and do not install the reverse or wrong model.
- Remove the battery if the device will not be used for a period of time. Otherwise, the battery will leak and damage the device.
- The device must never be subjected to shocks or impacts.
Declaration of Conformity
WS101 is in conformity with the essential requirements and other relevant
provisions of the CE, FCC, and RoHS.
Copyright © 2011-2022 Milesight. All rights reserved.
All information in this guide is protected by copyright law. Whereby, no
organization or individual shall copy or reproduce the whole or part of this
user guide by any means without written authorization from Xiamen Milesight
IoT Co., Ltd.
- For assistance, please contact Milesight technical support:
- Email: iot.support@milesight.com
- Tel: 86-592-5085280
- Fax: 86-592-5023065
- Address: Building C09, Software Park III, Xiamen 361024, China
Revision History
Date | Doc Version | Description |
---|---|---|
July 12, 2021 | V 1.0 | Initial version |
Dec. 7, 2021
|
V 1.1
| 1. Add LoRa D2D controller feature;
2. Delete low power alarm interval, device
only uplinks once when battery level is lower than 10%.
Product Introduction
Overview
WS101 is a LoRaWAN® based smart button for wireless controls, triggers and
alarms. WS101 supports multiple press actions, all of which can be defined by
the user to control devices or trigger scenes. Besides, Milesight also
provides a red button version that is primarily used for emergency situation.
Compact and battery-powered, WS101 is easy to install and carry everywhere.
WS101 can be widely used in smart homes, smart offices, hotels, schools, etc.
Sensor data are transmitted in real-time using the standard LoRaWAN® protocol.
LoRaWAN® enables encrypted radio transmissions over long distances while
consuming very little power. The user can get alarm through Milesight IoT
Cloud or through the user’s own Application Server.
Features
- Up to 15 km communication range
- Easy configuration via NFC
- Standard LoRaWAN® support
- Milesight IoT Cloud compliant
- Support multiple press actions to control devices, trigger a scene or send emergency alarms
- Compact design, easy to install or carry
- Built-in LED indicator and buzzer for press actions, network status, and low battery indication
Hardware Introduction
Packing List
- If any of the above items is missing or damaged, please contact your sales representative.
Hardware Overview
Dimensions (mm)
LED Patterns
WS101 equips with a LED indicator to indicate the network status and reset
button features. Besides, when button is pressed, the indicator will light up
at the same time. Red indicator means network is unregistered, while green
indicator means device has registered on network.
Function | Action | LED Indicator |
---|
Network Status
| Send join network requests| Red, blinks once
Joined the network successfully| Green, blinks twice
Reboot| Press and hold the reset button for more than 3s| Slowly blinks
Reset to Factory
Default
| Press and hold the reset button for more than 10s| Quickly blinks
Operation Guide
Button Mode
WS101 provides 3 kinds of pressing actions allowing users to define different
alarms. Please refer to chapter 5.1 for detailed message of every action.
Mode | Action |
---|---|
Mode 1 | Short press the button (≤3 seconds). |
Mode 2 | Long press the button (>3 seconds). |
Mode 3 | Double press the button. |
NFC Configuration
WS101 can be configured via NFC-enabled smartphone.
- Pull out the battery insulating sheet to power on the device. The indicator will light up in green for 3 seconds when device turns on.
- Download and install “Milesight ToolBox” App from Google Play or App Store.
- Enable NFC on the smartphone and open Milesight ToolBox.
- Attach the smartphone with NFC area to the device to read device information.
- Basic information and settings of devices will be shown on ToolBox if it’s recognized successfully. You can read and configure the device by tapping the Read/Write button on the App. In order to protect the security of devices, password validation is required when first configuration. The default password is 123456.
Note:
- Ensure the location of smartphone NFC area and it’s recommended to take off phone case.
- If the smartphone fails to read/write configurations via NFC, move the phone away and back to try again.
- WS101 can also be configured by ToolBox software via dedicated NFC reader provided by Milesight IoT, you can also configure it via TTL interface inside the device.
LoRaWAN Settings
LoRaWAN settings are used for configuring the transmission parameters in
LoRaWAN® network.
Basic LoRaWAN Settings:
Go to Device -> Setting -> LoRaWAN Settings of ToolBox App to configure join
type, App EUI, App Key and other information. You can also keep all settings
by default.
Parameters | Description |
---|---|
Device EUI | Unique ID of the device which can also be found on the label. |
App EUI | Default App EUI is 24E124C0002A0001. |
Application Port | The port used for sending and receiving data, default port |
is 85.
Join Type| OTAA and ABP modes are available.
Application Key| Appkey for OTAA mode, default is
5572404C696E6B4C6F52613230313823.
Device Address| DevAddr for ABP mode, default is the 5th to 12th digits of SN.
Network Session Key|
Nwkskey for ABP mode, default is 5572404C696E6B4C6F52613230313823.
Application
Session Key
|
Appskey for ABP mode, default is 5572404C696E6B4C6F52613230313823.
Spread Factor| If ADR is disabled, the device will send data via this spread
factor.
---|---
Confirmed Mode
| If the device does not receive ACK packet from network server, it will resend
data 3 times at most.
Rejoin Mode
| Reporting interval ≤ 30 mins: device will send specific mounts of LoRaMAC packets to check connection status every 30 mins; If no reply after specific packets are being sent, the device will re-join.
Reporting interval > 30 mins: device will send specific mounts of LoRaMAC
packets to check connection status at every reporting interval; If no reply after specific packets are being sent, the device will re-join.
ADR Mode| Allow network server to adjust datarate of the device.
Tx Power| Transmit power of device.
Note:
- Please contact sales representative for device EUI list if there are many units.
- Please contact sales representative if you need random App keys before purchase.
- Select OTAA mode if you use Milesight IoT Cloud to manage devices.
- Only OTAA mode supports rejoin mode.
LoRaWAN Frequency Settings:
Go to Setting->LoRaWAN Settings of ToolBox App to select supported frequency
and select channels to send uplinks. Make sure the channels match the LoRaWAN®
gateway.
If device frequency is one of CN470/AU915/US915, you can enter the index of the channel that you want to enable in the input box, making them separated by commas.
Examples:
- 1, 40: Enabling Channel 1 and Channel 40
- 1-40: Enabling Channel 1 to Channel 40
- 1-40, 60: Enabling Channel 1 to Channel 40 and Channel 60 All: Enabling all channels
- Null: Indicates that all channels are disabled
Note:
- For -868M model, default frequency is EU868;
- For -915M model, default frequency is AU915.
General Settings
Go to Device->Setting->General Settings of ToolBox App to change the reporting
interval, etc.
Parameters | Description |
---|
Reporting Interval
| Reporting interval of battery level to network server. Default: 1080min, Range: 1-1080 mins
LED Indicator
| Enable or disable the light indicating in chapter 2.4.
Note: The indicator of reset button is not allowed to disable.
Buzzer| The buzzer will be triggering together with indicator if the device is
| registered to network.
---|---
Change Password| Change the password for ToolBox App to write this device.
LoRa D2D Settings
LoRa D2D protocol is developed by Milesight and used for setting up
transmission among Milesight devices without gateway. When the LoRa D2D
setting is enabled, WS101 can work as a LoRa D2D controller to send control
commands to trigger LoRa D2D agent devices.
- Enable LoRa D2D feature.
- Define a unique LoRa D2D key which is the same as LoRa D2D agent devices, then s elect the frequency and spreading factor. (Default LoRa D2D Key: 5572404C696E6B4C6F5 2613230313823)
- Enable one of WS101 button mode and configure a 2-byte hexadecimal command (This command is pre-defined in LoRa D2D agent device). When you press as this button mode, WS101 will send the control command to corresponding LoRa D2D agent devices.
Note: When this feature is enabled, the device will not send uplinks to LoRaWAN® network server.
Maintenance
Upgrade
- Download firmware from Milesight website to your smartphone.
- Open ToolBox App and click “Browse” to import firmware and upgrade the device.
Note:
- Operation on ToolBox is not supported during upgrade.
- Only Android version ToolBox supports the upgrade feature.
Backup
WS101 supports configuration backup for easy and quick device configuration in
bulk. Backup is allowed only for devices with the same model and LoRa
frequency band.
- Go to “Template” page on the App and save current settings as a template. You can also edit the template file.
- Select one template file that saved in the smartphone and click “Write”, then attach it to another device to write the configuration.
Note: Slide the template item to the left to edit or delete the template. Click the template to edit the configurations.
Reset to Factory Default
Please select one of the following methods to reset device:
Via Hardware: Hold on the reset button for more than 10s. After reset complete, the indicator will blink in green twice and device will reboot.
Via ToolBox App: Go to Device -> Maintenance to tap “Reset”, then attach smartphone with NFC area to device to complete reset.
Installation
3M Tapes Fix:
Paste 3M tape to the back of the button, then tear the other side and place it
on a flat surface.
Screw Fix:
Remove the back cover of the button, screw the wall plugs into the wall and
fix the cover with screws on it, then install back the device.
Lanyard:
Pass the lanyard through the aperture near the edge of the button, then you
can hang the button onto keychains and the like.
Device Payload
All data are based on the following format(HEX):
Channel1 | Type1 | Data1 | Channel2 | Type2 | Data2 | Channel 3 | … |
---|---|---|---|---|---|---|---|
1 Byte | 1 Byte | N Bytes | 1 Byte | 1 Byte | M Bytes | 1 Byte | … |
For decoder examples you can find at https://github.com/Milesight- IoT/SensorDecoders.
Basic Information
WS101 reports basic information of button whenever joining the network.
Channel | Type | Description |
---|
ff
| 01(Protocol Version)| 01=> V1
08 (Device SN)| 12 digits
09 (Hardware Version)| 01 40 => V1.4
0a (Software Version)| 01 14 => V1.14
0b (Power On)| Device is on
0f (Device Type)| 00: Class A, 01: Class B, 02: Class C
Example:
ff0bff ff0101 ff086538b2232131 ff090100 ff0a0102 ff0f00
Channel| Type| Value| Channel| Type| Value
ff| 0b
(Power On)
| ff (Reserved)| ff| 01
(Protocol Version)
| 01 (V1)
Channel| Type| Value| Channel| Type| Value
ff| 08(Device
SN)
| 6538b22321
31
| ff| 09
(Hardware version)
| 0100
(V1.0)
Channel| Type| Value| Channel| Type| Value
ff
| 0a (Software
version)
| 0102 (V1.2)|
ff
| 0f (Device Type)| 00
(Class A)
Button Message
WS101 reports battery level according to reporting interval (1080 mins by
default) and button message when button is pressed.Besides, when battery level
is lower than 10%, it will upload battery pakcage once.
Channel | Type | Description |
---|---|---|
01 | 75(Battery Level) | UINT8, Unit: % |
ff
|
2e(Button Message)
| 01: Mode 1(short press) 02: Mode 2 (long press)
03: Mode 3 (double press)
Example:
01 75 64
Channel| Type| Value
01| 75 (Battery)| 64 => 100%
ff 2e 01
Channel| Type| Value
ff| 2e(Button Message)| 01 => short press
Downlink Commands
WS101 supports downlink commands to configure the device. The application port
is 85 by default.
Channel | Type | Description |
---|---|---|
ff | 03 (Set Reporting Interval) | 2 Bytes, unit: s |
Example: Set reporting interval as 20 minutes.
ff03b004
Channel| Type| Value
ff| 03 (Set Reporting Interval)| b0 04 => 04 b0 = 1200s
= 20 minutes
Rémy GUÉDOT
Gsm: +33 (0) 662 80 65 57
Olivier BENAS
Gsm: +33 (0) 666 84 26 26
14 rue Edouard Petit F42000 Saint-Etienne
- Tél: +33 (0) 477 92 03 56
- Fax: +33 (0) 477 92 03 57
- guedot@rg2i.fr
- olivier.benas@rg2i.fr
ATTENTION- NOUVELLE ADRESSE
www.rg2i.fr
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>