Shark IZ500 Series Cordless Pro Vacuum User Guide
- June 9, 2024
- Shark
Table of Contents
Shark IZ500 Series Cordless Pro Vacuum
SHARK® CORDLESS PRO IZ500 SERIES
IMPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF INJURY, USER MUST READ INSTRUCTION MANUAL
• HOUSEHOLD USE ONLY
WARNING When using an electrical appliance, to reduce the risk of fire,
electric shock, injury.
-
This vacuum consists of a motorized nozzle, wand, and handheld vacuum. These components contain electrical connections, electrical wiring, and moving parts that potentially present risk to the user. The floor nozzle, wand, and handheld vacuum contain electrical connections.
-
Before each use, carefully inspect all parts for any damage. If a part is damaged, discontinue use.
-
Use only identical replacement parts.
-
This vacuum contains no serviceable parts.
-
Use only as described in this manual. DO NOT use the vacuum for any purpose other than those described in this manual.
-
with the exception of the filters and dust cup, DO NOT expose any parts of the vacuum to water or other liquids.
-
Keep the appliance and its cord out of reach of children. DO NOT allow the appliance to be used by children. DO NOT allow to be used as a toy. Close supervision is necessary when used near children. GENERAL USE
-
This appliance can be used by persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Cleaning and user maintenance shall not be made by children.
-
Always turn off the vacuum before connecting or disconnecting any current carrying hoses, motorized nozzles, chargers, batteries, or other electrical or mechanical parts.
-
DO NOT handle plug or vacuum with wet hands.
-
DO NOT use without dust cup, HEPA and Pre-motor filter, and
soft roller in place. -
Only use Shark® branded filters and accessories. Failure to do so
will void the warranty. -
DO NOT put any objects into nozzle or accessory openings. DO
NOT use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce airflow. -
DO NOT use if nozzle or accessory airflow is restricted. If the air paths or the motorized floor nozzle become blocked, turn the vacuum off. Remove all obstructions before you turn on the unit again.
-
Keep nozzle and all vacuum openings away from hair, face, fingers, uncovered feet, or loose clothing.
-
DO NOT use if vacuum is not working as it should, or has been dropped, damaged, left outdoors, or dropped into water.
-
Use extra care when cleaning on stairs.
-
DO NOT leave the vacuum unattended while powered on.
-
When powered on, keep the vacuum moving over the carpet surface at all times to avoid damaging the carpet fibers.
-
DO NOT place vacuum on unstable surfaces such as chairs or tables.
-
DO NOT use to pick up:
- Liquids
- Large objects
- Hard or sharp objects (glass, nails, screws, or coins)
- Large quantities of dust (including drywall, fireplace ash, o er mbers). DO NOT use as an attachment to power tools for dust collection.
- Smoking or burning objects (hot coals, cigarette butts, matches)
- Flammable or combustible materials (lighter fluid, gasoline, or kerosene)
- Toxic materials (chlorine bleach, ammonia, or drain cleaner)
-
DO NOT use in the following areas:
- Poorly lit areas
- Wet or damp surfaces
- Outdoor areas
- Spaces that are enclosed and may contain explosive or toxic fumes or vapors (lighter fluid, gasoline, kerosene, paint, paint thinners, mothproofing substances, or flammable dust)
-
Turn off the vacuum before plugging in or unplugging the charger.
-
Turn off the vacuum before any adjustment, cleaning, maintenance or troubleshooting.
-
During cleaning or routine maintenance, DO NOT cut anything other than hair, fibers, or string wrapped around the brushrolls.
-
Allow all filters to air-dry completely before replacing in the vacuum to prevent liquid from being drawn into electric parts.
-
DO NOT modify or attempt to repair the vacuum or the battery yourself, except as indicated in this manual. DO NOT use the battery or vacuum if it has been modified or damaged. Damaged or modified batteries may exhibit unpredictable behavior resulting in fire, explosion, or risk of injury.
-
Always turn off this appliance before connecting or disconnecting motorized nozzle or hand tool.
BATTERY PACK -
The battery is the power source for the vacuum. Carefully read and follow all charging instructions.
-
To prevent unintentional starting, ensure the vacuum is powered
off before picking up or carrying the vacuum. DO NOT carry the appliance with your finger on the power switch. -
Use only Shark® charger DK33-248080H-U or YLS0243A-T248080 for single batteries packs. Use of an incorrect charger may result in
no charging, and/or unsafe conditions. A charger that is suitable for one type of battery pack may create a risk of fire when used with another battery pack. -
Keep the battery away from all metal objects such as paper clips, coins, keys, nails, or screws. Shorting the battery terminals increases the risk of fire or burns.
-
Under abusive conditions, liquid may be ejected from the battery. Avoid contact with this liquid, as it may cause irritation or burns. If contact occurs, flush with water. If liquid contacts eyes, seek medical help.
-
Battery should not be stored at temperatures below 3°C (37.4°F)
or above 104°F (40°C) to maintain long-term battery life. -
DO NOT charge battery at temperatures below 5°C (40°F) or above 104°C (104°F). Charging improperly or at temperatures outside of the specified range may damage the battery and increase the risk of fire.
-
Store the appliance indoors. DO NOT use or store it below 3°C (37.4°F). Ensure the appliance is at room temperature before operating.
-
DO NOT expose the battery to fire or temperatures above 265°F
(130°C) as it may cause explosion. -
Use appliances only with specifically designated battery packs. Use of any other battery packs may create a risk of injury and fire.
-
Disconnect the battery pack from the appliance before making
any adjustments, changing accessories, or storing appliance. Such preventive safety measures reduce the risk of starting the appliance accidentally. -
For IZ500 Series use only with Shark battery pack XBATR620SL or XBATR625SL.
-
If the charging cord plug does not fit fully into the outlet, reverse
the plug. If it still does not fit, contact a qualified electrician.
DO NOT force into outlet or try to modify to fit. -
To reduce the risk of shock and unintended operation, turn off power and remove the Li-Ion battery before servicing. ODOR
-
Observe the following when interacting with the odor neutralizing cartridge:
-
DO NOT attempt to disassemble odor neutralizing cartridge.
-
Avoid direct contact with the fragrance pod in the cartridge.
-
DO NOT directly inhale from the odor neutralizing cartridge.
-
Keep away from children and pets.
-
Keep away from heat, sparks, and open flame.
-
DO NOT place in direct sunlight.
FRAGRANCE CARTRIDGE FIRST AID -
Avoid contact with fabrics and finished surfaces.
-
Eye contact: Remove contact lenses if present. Rinse continuously with water for several minutes.
-
Skin contact: Wash hands thoroughly after handling. If irritation or rash develops, seek medical advice/attention.
-
Inhalation: Move person to fresh air if they are experiencing
any respiratory symptoms. If symptoms persist, seek medical advice/attention. -
Ingestion: DO NOT induce vomiting. Seek medical advice/attention.
-
READ AND SAVE THESE INSTRUCTIONS
VISIT
qr.sharkclean.com/iz500seriesmanual
OR SCAN HERE
FOR FULL INSTRUCTIONS & REPLACEMENT PARTS
SETTING UP YOUR UNIT
- Insert Wand into Floor Nozzle.
- Insert Handheld Vacuum into wand.
- Remove Odor Neutralizer Technology Dial from bag. Flip up the dial handle, align the teal arrows, then insert the dial into the nozzle. Using the handle, rotate the dial until it clicks into the desired intensity setting.
- After reading it, remove the sticker from the hand vacuum’s digital screen.
For proper operation, ensure all components are completely connected and clicked into place.
SETTINGS
Press power button to turn vacuum on or off.
NOTE: The unit will not turn on if the charger is connected. Unplug the
charger before turning on vacuum power.
Press the power button to toggle between ECO, Clean Sense IQ, and Boost modes. To save battery power, select ECO mode. For everyday cleaning power, select Clean Sense IQ mode. For an extra burst of power, select Boost mode
Align the teal arrow on the dial with the teal arrow on the nozzle, then
insert the dial into the nozzle. Rotate the dial counterclockwise until it
clicks into an intensity setting to engage. Rotate further to change the
intensity setting.
For IZ562H only.
The Clean Indicator visually confirms when floors are clean. When the unit senses heavy debris, suction will increase for more cleaning power. When the debris is cleared, suction will decrease. The clean indicator displays the level of debris detected. For best results, continue cleaning until the indicator returns to its lowest level before moving to the next area.
ESSENTIAL MAINTENANCE
CLEANING THE FILTERS
Regularly rinse and replace the filters to maintain your vacuum’s suction power
and to maximize the effectiveness of odor neutralization.
To clean filters, rinse them with water only. Allow all filters to air-dry
completely for up to 48 hours before reinstalling to prevent liquid from being
drawn into electric parts. Clean the pre-motor filters at least once a month
and post-motor filter at least once a year. Tap off loose dirt between washes
when needed. More frequent cleaning may sometimes be necessary with heavy use.
IMPORTANT: DO NOT use soap when cleaning the filters. Use water only. The vacuum will not have suction if the post-motor filter is not installed. Ensure that all filters are installed before using.
CLEANING THE SENSORS
Make sure to clean the sensors inside the hand vacuum regularly, as hair and other debris may build up and obstruct them. If the sensors are partially obstructed, Clean Sense IQ mode will not adjust suction levels as expected. If the sensors are completely obstructed, the F0 error code will appear and the Clean Sense IQ icon will flash on the hand vacuum display panel.
To clean the sensors:
-
Turn off power and remove the hand vacuum.
-
Locate the sensors inside the nozzle of the hand vacuum. The sensors are on the interior walls of the nozzle, about 3 inches down the air path, aligned with the IQ logos (Fig.2) on the exterior.
-
Gently wipe the sensors with a microfiber cloth and remove all hair and debris.
-
Turn on power and verify that the unit is functioning normally.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>