Mytee LTD5-LX Carpet Extractor with Auto Pump User Manual

June 9, 2024
MYTEE

Mytee LTD5-LX Carpet Extractor with Auto Pump

Dear Customer

Congratulations on the purchase of your new Speedster® LTD Carpet Extractor. As technology continues to develop you can work confidently knowing that both Mytee and its employees are equally dedicated to developing with the industry and its advances.

Like any other piece of machinery or technology, the Speedster® LTD also requires proper maintenance and care to keep the product working over extended use. Neglecting your machine, abusing it or not operating it properly can void its warranty and prevent the machine from performing to the quality and standard you’d expect out of the Mytee line. If you have any warranty concerns or questions, please review this manual thoroughly or do not hesitate to contact your distributor.

If there are questions regarding maintenance, replacement, or ordering parts please contact an authorized Mytee Service Center. To see an updated list please visit our website at http://www.mytee.com/support/service-centers. Before using your Mytee product, please read this manual thoroughly.

Sincerely,
Mytee Customer Care Dept.

Important Safety Information

Please read and understand this manual completely before operating this machine.

Grounding Instructions

This machine must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electrical shock. This machine is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged into an appropriate outlet that is properly installed in accordance with all local code and ordinances. Do not remove ground pin; if missing, replace plug before use.

DANGER Improper installation of the equipment-grounding conductor can result in a risk of electric shock. Be sure to check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. If the plug will not fit in the outlet do not modify the plug or the machine’s cord, instead have a proper outlet installed by a qualified technician.

This machine is for use on a nominal 120-volt circuit and with a grounding plug similar to the one in Figure 1 below. If a proper outlet is not available, follow the illustrations of  Figure 2 & 3 to install a temporary- grounding plug. This temporary work-around should be used only until a proper outlet (Figure 1) can be installed by a qualified electrician. When and if this type of adapter is employed, screw the adapter’s extended tab into place with a metal screw.  However, grounding adapters are not approved for use in Canada.

Again, be sure to check the grounding pin for damages and replace if necessary.

The Green, or Green-Yellow, wire in the cord is the grounding wire. When replacing a plug, this wire must be attached to only the grounding pin.

DO NOT use extension cords

Please Note for America use only.

Parts and Service
Please contact Mytee service personnel or a Mytee authorized Service Center using Mytee original replacement parts and accessories if repairs need to be performed. When and if calling Mytee for support, please have your Model and Serial Number available for faster assistance.

Name Plate
The Model and Serial Number are located on the lower half of the back of the machine near the power plug and will be required for ordering replacement parts. You can  use the space provided in this manual to note down both for future referencing.

Unpacking the Machine
When your new machine is delivered, please carefully inspect both the shipping carton and the machine for damages. If damage is evident, save both the shipping carton and machine so that the delivering carrier can inspect it. Contact the carrier immediately to file a freight claim if there has been any damage.

Caution and Warnings Symbols

Mytee uses the symbols below to signal potentially dangerous conditions. Always read this information carefully and take the necessary steps to protect personnel and property.

DANGER Is used to warn of immediate hazards that will cause severe personal injury or death.
WARNING   Is used to call attention to a situation that could cause severe personal injury.
CAUTION Is used to call attention to a situation that could cause minor personal injury or damage to the machine or other property. When using an electrical appliance, basic precautions should always be followed, including the following: Read all instructions before using this machine. Figure 1 This product is intended for commercial use only.

To reduce the risk of fire, electrical shock, or injury:

  1. Read all instructions before using equipment.
  2. Use only as described in this manual. Use only manufacturer’s recommended attachments.
  3. Always unplug power cord from electrical outlet before attempting any adjustments or repairs.
  4. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
  5. Do not pull or carry by cord. Do not close a door on cord or pull cord around sharp edges or corners.
  6. Do not run appliance over cord. Keep cord away from heated surfaces.
  7. Do not use with damaged cord or plug. If cord is damaged, repair immediately.
  8. Do not use outdoors or on wet surfaces and/or standing water.
  9. Always unplug or disconnect the appliance from power supply when not in use.
  10. Do not allow to be used as a toy. Close attention is necessary when used by or near children.
  11. Do not use in areas where flammable or combustible material may be present.
  12. Do not leave the unit exposed to harsh weather elements. Temperatures below freezing may damage components and void warranty.
  13. Use only the appropriate handles to move and lift unit.
  14. Do not use any other parts of this machine for this purpose.
  15. Do not pull on hoses in order to move the unit. Only use the appropriate handles.
  16. Keep hair, loose clothing, fingers, and all parts of the body away from all openings and moving parts.
  17. Use extra care when using on stairs.
  18. To reduce the risk of fire or electric shock, do not use this machine with a solid-state speed control device.
  19. The voltage and frequency indicated on the name plate must correspond to the wall receptacle supply voltage.
  20. When cleaning and servicing the machine, local or national regulations may apply to the safe disposal of liquids which may contain: chemicals, grease, oil, acid, alkalines, or other dangerous liquids.
  21. Do not leave operating unattended

At a Glance

Technical Specifications

LTD3

Recovery Tank 11 gallon capacity (approx.)
Solution Tank 11 gallon capacity (approx.)
Vacuum Motors Dual 3-stage, 200 CFM, 130” water lift
Solution Pump 500 PSI, 1.5 GPM
Pump-Out 3.3 GPM
Heater 1,600 watt – 210º max.
Wheels 10” foam-filled
Casters 4” locking
Power Cord Dual 50’ 12/3
Amp Draw Cord 1: 20 amps @ 115V 60Hz Cord 2: 20 amps @ 115V 60Hz
Machine Weight 165 lbs.
Machine Dimensions 30” x 20” x 42”

LTD12-LX

Recovery Tank 11 gallon capacity (approx.)
Solution Tank 11 gallon capacity (approx.)
Vacuum Motors Dual exclusive Mytee® LX™ Vacuum Motors – 225-250 CFM,

145” water lift
Solution Pump| Adjustable 1,200 PSI (regulated to 1,000 PSI), 2.2 GPM
Pump-Out| 3.3 GPM
Wheels| 10” foam-filled
Casters| 4” locking
Power Cord| Dual 50’ 12/3
Amp Draw| Cord 1: 20 amps @ 115V 60Hz Cord 2: 15 amps @ 115V 60Hz
Machine Weight| 154 lbs.
Machine Dimensions| 30” x 20” x 42”

LTD5-LX

Recovery Tank 11 gallon capacity (approx.)
Solution Tank 11 gallon capacity (approx.)
Vacuum Motors Dual exclusive Mytee® LX™ Vacuum Motors – 225-250 CFM,

182” water lift
Solution Pump| 500 PSI, 1.5 GPM
Pump-Out| 3.3 GPM
Wheels| 10” foam-filled
Casters| 4” locking
Power Cord| Dual 50’ 12/3
Amp Draw| Cord 1: 20 amps @ 115V 60Hz Cord 2: 14 amps @ 115V 60Hz
Machine Weight| 135 lbs.
Machine Dimensions| 30” x 20” x 42”

Included with the Speedster® LTD
  • H141V Cuff-Lynx™ Reduce

  • H110V Cuff-Lynx™ Coupler

  • H226 Drain Spout

  • A157 Auto-Fill Adapter

  • A145 Loading Buddy Wheel Kit (INCLUDED WITH LTD5-LX and LTD12-LX

  • 2x E351A 50’ Power Cords

  • P535 5 qt. Bottle

  • H547 Bottle Hanger & Screws

Speedster® LTD Features

  1. Push handle
  2. Clear recovery tank lid
  3. Recovery tank
  4. 5 qt. Big Mouth™ Bottle
  5. Base vents
  6. 10” foam-filled wheels
  7. 4” locking casters
  8. Pressure regulator (regulator placement varies by model)
  9. Solution tank
  10. Chemical injection meter
  11. Front lift handle
  12. Quick connect fitting for solution line featuring prime valve
  13. 2” Cuff-Lynx™ starter
  14. Switch plate
  15. Recovery tank drain valve
  16. Vacuum exhaust ports
  17. Maintenance access latches
  18. Solution tank drain cap
  19. Twist-lock power cord sockets
  20. Auto-fill connection
  21. Pump-out connection
Switch Plate

  1. Vacuum switches.
  2. Pump switch.
  3. Pump-out switch.
  4. Heater three-position switch (not installed on LTD5 and LTD12).
  5. Heater indicator lights. Each light illuminates when the corresponding heater is on (not installed on LTD5 and LTD12).
  6. Dual circuit indicator light.
  7. Pressure gauge.

Machine Operation

Before Operating
Take the included mesh filter bag and place it over the pump-out filter inside the black recovery tank. This filter helps prevent any solid debris from damaging the pump-out. ♦

Powering the Speedster® LTD

Each power cord on the Speedster® LTD requires a grounded 20 amp outlet. For dual cord machines, plug each cord into its own 20 amp circuit. The dual circuit indicator light and tone will activate when this is achieved. ♦

Machine Components on each cord. Primary Cord always marked with yellow tag.

LTD3 Primary Cord: Vacuum 1 600 Watt Heater Pump
Secondary Cord: Vacuum 2

1,000 Watt Heater Pump-Out

LTD5-LX| Primary Cord:| Vacuum 1 Pump
Secondary Cord:| Vacuum 2 Pump-Out
LTD12-LX| Primary Cord:| Vacuum 1 Pump
Secondary Cord:| Vacuum 2 Pump-Out

Connecting Vacuum & Solution Hoses

Use the included Cuff-Lynx™ hose connectors to connect 1.5” or 2” vacuum hose to the Speedster® LTD. Connect the solution hose via the quick connect fitting on the front of the Speedster® LTD. ♦

Filling the Solution Tank

The Speedster® LTD solution tank can be filled up from a bucket via the opening under the solution tank lid or viathe auto-fill feature (section 2.5).

IMPORTANT: Use only low foam or non foaming detergent or shampoo. Damage due to excessive foam will void warranty.

IMPORTANT: Do not use acid (acid rinse) or high alkaline chemicals like sodium hydroxide in the LTD3 or LTD5-LX machines. This will cause damage to the pump and void the warranty. ♦

Switching on the Speedster® LTD

Units Without Heater (LTD5-LX, LTD12, LTD12-LX) After a cleaning tool is connected and the solution tank is filled, switch on the vacuums and the pump in any order.
Units With Heater (LTD3)

In order to avoid vapor locking the unit, the components should be switched on by following the procedure below after a cleaning tool is connected:

  1. Turn pump switch on. Pull the lever on the cleaning tool to release air in the line. Hold lever until a steady flow of water comes out of the wand.
  2. Once pump is primed and there is pressure in the solution line, turn on heater switch and wait a few minutes for water to heat up.
  3. Once water is heated, turn on vacuum and begin cleaning. ♦
Chemical Injection

Fill the included 5 qt. bottle with chemical concentrate of your choice. With a cleaning tool connected, switch on the pump and pull the trigger on your tool to keep water flowing. Turn the chemical injection knob counter-clockwise to open the valve. This allows chemical to siphon into the line. Turn the knob until you see the bubble reach the desired gallons per hour of chemical. Follow chemical manufacturer’s instructions for correct ratio.

IMPORTANT: If chemical injection will not be used, make sure the chemical injector is closed by turning the knob all the way clockwise. ♦

The Auto-Fill & Pump-Out Features

Auto-fill: Connect standard garden hose from water source to LTD auto-fill connection. Turn on the water source and let the tank begin to fill. It will shut off when the water level reaches the float switch in the solution tank.

Pump-out: Connect a second standard garden hose to the LTD’s pump-out connection and lay the other end of the hose in a draintable location. Activate the pump-out switch on the front of the machine and open the ball valve on the pump-out connection. The LTD will automatically drain recovered water from the tank. ♦

The Prime Valve

The Speedster® LTD units come with a prime valve attached to the solution hose quick connect fitting. Turning the valve lever to position 1 directs flow towards the wash hose inside the solution tank. Turning the lever to position 2 directs flow towards the cleaning tool. ♦

Emptying the Recovery Tank

Empty the recovery tank by attaching the H226 45˚ drain elbow to the drain spout in back. Lift up the dump valve and empty the tank into a bucket or drain.

Rinse out the recovery tank using the wash hose inside the solution tank. Take the lid off the recovery tank and place the end of the wash hose inside. With solution or clean water in the solution tank, switch on the pump and turn the prime valve to position 1 (shown in section 2.6). Rinse off the inside of the recovery tank and then drain the tank. ♦

Emptying the Solution Tank

The Speedster® LTD has a solution tank drain cap on the back of the machine. Just unscrew this cap to drain unused solution into a bucket or other receptacle. ♦

Machine Maintenance

In order to keep the Speedster® LTD running smoothly and reduce the risk of damage to the machine and subsequent downtime, Mytee recommends  following the maintenance schedule below:

Maintenance Item Daily Weekly
Clean and inspect tanks. X
Clean and inspect hoses. X
Check and clean internal filters. X
Check power supply cable. X
Clean machine with all-purpose cleaner and cloth. X
Check spray nozzles. X
Flush solution system with Mytee System Maintainer.   X
Inspect vacuum hoses for holes and loose cuffs.   X

Inspect spray pattern for clogging.   If clogged, remove spray tips and soak them in a recommended liquid neutralizer for up to six hours. To remove spray tip, twist spray tip body counter-clockwise.|  |

X

Lubricate wheels with water resistant oil.|  | X
Inspect machine for water leaks and loose hardware.|  | X

Opening the Unit for Maintenance

To open the Speedster® LTD, loosen the rear latches by turning them one quarter turn counter-clockwise. Flip the latches down and then lift up on the push handle and the machine will open up. ♦

Filter Maintenance

The Speedster® LTD comes with a nylon mesh bag filter that should be placed over the pump-out filter on the bottom of the recovery tank. The nylon bag filter, the pump-out filter, and the solution filter inside the solution tank should be checked and cleaned on a daily basis. ♦

Ball Float Maintenance

The ball floats in the recovery tank prevent recovered dirty water from rising too high and damaging the vacuum motors. Clean the mesh screen on the floats regularly. ♦

System Maintainer

Weekly flushing of the solution system with Mytee® System Maintainer helps keep lines clean and prevents chemical build-up, improving pump life, performance and pressure.

How to use System Maintainer:

  1. Mix 1-quart 3601 System Maintainer with 1-quart of warm water.
  2. After thoroughly mixing, pour this solution into the solution tank.
  3. Turn the pump on FIRST, and run solution through your cleaning tool. NOTE: The jet should be removed from the cleaning tool in order to prevent clogging due to loosening of deposits in line.
  4. Next, turn on the heater (if equipped). If the heater isturned on first, it will result in a vapor lock, which will affect the machine’s operation.
  5. Next, with both the pump and heater on, begin running the solution through the machine. This allows the solution to break down any build up in the lines.
  6. After running all of the solution through the machine, fill the tank with clean, warm water. Run the water through the machine to clear the solution completely out of the tank & lines. ♦

Available Accessories



Troubleshooting

Vacuum is not turning on.

Possible Cause| Solution
Vacuum may not be getting power.| Check the electrical connections and the switch. Look for loose or damaged wires.
To check the switch: Unbolt the switch plate. Take a picture of the layout of the wires or tagging the wires for future reference.
Switch the wires from the vacuum switch with the wires from either the pump or heater switch.
Turn on the pump or heater switch (whichever one you exchanged wires with). If the vacuum turns on, then you know the vacuum switch is bad.
Vacuum is not producing suction.
Possible Causes| Solutions
Recovery tank is full.| Empty the recovery tank.
If the vacuum exhausts but there is no suction, then the hose from the recovery tank to the vacuum motor is disconnected.| Open the machine and find the hose running from the recovery tank to the vacuum motor. Check if it is disconnected. If so, reconnect it. If it has a leak, replace the hose ( **Part

PH627 if 1.5”, PH628 if 2”** ).

Vacuum hose blockage (if there is no suction or exhaust).| Check for blockage in the hose, starting from the cleaning tool to the machine.
Clogged filter in vacuum tank.| Clean out filter regularly.
Drain valve/cap is loose and is causing air leakage.| Tighten the drain valve/cap.
Hose cuffs are loose and causing air leakage.| Tighten all hose cuffs regularly as may loosen over time. Use a glue to prevent cuffs from coming loose (optional).
Lid on tank is loose  and is causing air  leakage.| Make sure the lid is tight.
Vacuum blows water out the exhaust.
Possible Causes| Solutions
Foam building up in the recovery tank.| Use a defoaming solution in the recovery tank.
There is a loud grinding noise coming from the vacuum.
Possible Cause| Solution
Debris has been sucked into the vacuum motor chamber. Usually results from dry vacuuming.| Replace the vacuum motor. To avoid repeat problem, DO NOT dry vacuum with your extractor.
Pump doesn’t turn on.

Possible Causes| Solutions
Bad switch at control panel.| Unbolt the switch plate. We recommend taking a picture of the layout of the wires or tagging the wires for future reference. Switch the wires from the pump switch with the wires from either the vacuum or heater switch. Turn on the vacuum or heater switch (whichever one you exchanged wires with). If the pump turns on, the pump switch is bad.
Loose or disconnected wire.| Disconnect the power cord from the electrical outlet. Open up the machine and look for any loose or dis- connected wires. Re-attach or replace wires.
Pump runs but there is no spray.

Possible Causes| Solutions
On a new unit, the check valve between the pump and heater may hang up, causing the flow of water to be impeded or stop entirely.| Remove the check valve temporarily and check to see if the pump will flow water out of the pump outlet hose when the pump is turned on for a brief instant in order to verify cause. The remedy is to install a new check valve. Observe the proper orientation (flow direction) of the check valve. Tip: the check valve may be able to be temporarily returned to service by un-sticking the check valve poppet with manipulation of the poppet ball with a thin tool, like a straight- ened paperclip. Replace the check valve in unit assembly.
NEVER OPERATE A UNIT WITHOUT A CHECK VALVE IN PLACE.
Pump runs for a second then shuts down.

Possible Causes| Solutions
QD is pressure locked.| Relieve pressure from behind the QD by pressing in the button inside the QD.
Low PSI.

Possible Causes| Solutions
The jet nozzle could be too large.| Replace the jet with one that has a smaller opening.
Pump doesn’t stop running.

Possible Causes| Solutions
Leak somewhere in the line.| Disconnect the solution hose from the machine. If this causes the pump to stop running then the problem is outside the machine, either in the solution hose or tool. If it continues running on, open the machine and check for leaks. Repair the leak. If there are no leaks, run Mytee’s System Maintainer™ ( Part # 3601 ) through the machine to clear blockages.
Cracks or vacuum leaks on inlet side of pump.| Make sure hoses are secured tightly. If the inlet side of the pump is cracked or damaged, replace the pump.
Seals have been degraded by chemical.| Install seal repair kit.
Debris blocking inlet filter or pump head.| Clean filter and/or pump head.
Pump trips circuit breaker when turned on.

Possible Causes| Solutions
Short in power switch.| Test by swapping vacuum and pump switch. If problem resolves, but vacuum begins tripping breaker, replace switch ( Part #E515 ).
Short in electrical harness.| Risk of electric shock. Do this at your own risk.
Remove pump from circuit by attaching power leads together. If breaker still pops when switch is toggled, then there is a short to the ground in the circuit. Replace wires as needed.
Short in pump motor.| If switch and harness check is OK, the short may be in the pump motor. Replace pump.

Click here for more detailed information.

Heater Troubleshooting

Heater is not heating water.

Possible Causes| Solutions
Loose electrical connection.| Check all electrical connections, including power cord and harness.
Automatic sensor has failed, causing manual sensor to trip.| Reset the manual sensor button by pressing the small white and yellow button in the center of the sensor. If this works, but heater continues to trip the manual sensor, replace the automatic sensor ( Part #E573 ) on the heater.
Heater element has failed.| Check for  continuity through the element by reading the amperage. If amps are low, only part of the element may be heating up – in this case, the element is damaged and needs to be replaced.
Bad power switch.| If the element, sensors, and wiring all check out okay, there may be a bad switch on the switch-plate.
Running out of hot water too fast.

Possible Causes| Solutions
Too much water flowing through the heater.| Remember, when using your machine, it is recommended you do one wet pass followed by two dry passes. This way you are not spraying as much and the hot water will last longer.
Jets being used are too large.| If your machine has a 1,000W or 1,200W heating system, make sure your cleaning tool has 0.02 jets.
Water in tank is very cold.| If possible, fill your solution tank with warm water in order to shorten the amount of time it takes for the water to heat up. The pumps are usually rated for 140°F water.
Heater has hard water buildup inside, leading to lost efficiency.| Run Mytee System Maintainer™ ( Part # 3601 ) through the machine regularly in order to clear hard water or chemical residue that can block water flow and reduce heating ability. See product label for instructions.
Unit has vapor locked and there is no water pumping out of the unit.

Possible Cause| Solution
Turning on the heater before turning on the pump and priming the unit.| Turn off the heater and allow the unit to cool completely. When machine has cooled, turn on the pump first. Prime the unit by spraying solution out of the cleaning tool. Then, turn on the heater.

Click here for more detailed information.

Mytee, LLC
13655 Stowe Dr.
Poway, CA 92064
www.mytee.com
© 2022 Mytee, LLC
Printed in the USA