MYTEE Dry GT Upholstery Tool User Manual
- June 5, 2024
- MYTEE
Table of Contents
MYTEE Dry GT Upholstery Tool
Package Contents:
Setup :
Choose between the included blue and black comfort grips. Clean the
indentation area on the tool thoroughly with alcohol. Peel off the adhesive
backing and stick the grip onto the tool within the indentation. The vacuum
hose can be connected directly to an extractor. If a longer hose length is
necessary, connect to another hoseusing the included barb-to-barb fitting.
Connect the male quick connect fitting from the solution line to the female
solution quick connect fitting either on the extractor or a
longer solution hose.
Warning: Brass fittings can be extremely hot during and after use. Tightly wrap the included Heatguard Hose Wrap around exposed fittings to prevent burns.
Using the Mytee Dry GT in the Field
-
After the Mytee Dry GT is connected to your extractor, turn on the extractor’s vacuum(s) and then the solution pump (if they’re on separate switches).
-
Make sure the ball valve at the end of the solution hose is turned parallel to the hose, allowing solution
to flow through. -
Dial in the desired amount of solution flow using the flow control knob. The amount of solution flow
needed will depend on the material, its absorbency, and how soiled it is. Turn the knob counterclockwise to restrict flow and clockwise for higher flow . -
Use the vacuum release dial to relieve some suction if necessary. In general, you’ll want to relieve more vacuum the more delicate the material is. Just twist the dial to reveal the vacuum release holes.
-
Begin cleaning by moving the cleaning head of the tool back and forth on the upholstery material.
Maintenance
Main tenance A ction | F r equen c y |
---|
Rinse out any left over chemicals or dirt residue by running clean water
through the tool.| After each use.
Check spray bar for any clogged orifices. If there’s a clog, clear the
obstruction with a small needle.| After each use.
Clean the inline filter behind the quick connect fitting on the solution hose
(#21 in the diagram below).| When there’s a noticeable loss of solution flow.
Wipe the tool down with a damp cloth.| As often as needed.
Useful Tips
Rinsing out inside the tool: If there’s a buildup of dirt inside the
tool that can’t be removed by running clean water through it, remove the clear
window in order to clean out the inside of the tool. When done, reattach the
window.
Cutting off solution flow: Fine-tuning of the solution flow can be done
with the flow control knob on top of the tool. You can also completely shut
off flow by turning the same knob all the way clockwise.
Switching between hose cuffs. To remove a hose cuff from the hose, twist the
cuff clockwise.
Switching between hose cuffs: To remove a hose cuff from the hose, twist the cuff clockwise until it comes off. Twist a new cuff all the way on using a counter clockwise motion.