LANCOM SYSTEMS LANCOM 1790-4G Plus High-Performance VPN Router Instruction Manual
- June 4, 2024
- LANCOM SYSTEMS
Table of Contents
SYSTEM Hardware Quick Reference
LANCOM 1790-4G+
-
LTE / 4G antennas
Connect the two supplied cellular antennas to the connectors Ant 1 and Ant 2. -
WAN interface
Connect the WAN interface to your WAN modem using the enclosed ethernet cable with the dark green connectors.
-
Ethernet interfaces
Use the cable with the green-colored connectors to connect one of the interfaces ETH 1 to ETH 3 to your PC or a LAN switch. -
SIM card slot (bottom side of the device)
Release the SIM-card holder and lever it upwards. Slide the SIM card into the guide slot of the SIM-card holder. Press the holder down until it clicks into place. -
Configuration interface
Configuring the device via the serial interface requires a serial configuration cable (available as an accessory). -
USB interface
You can use the USB interface to connect a USB printer or a USB memory stick. -
Power
After connecting the cable to the device, turn the bayonet connector 90° clockwise until it clicks into place.
Use only the supplied power adapter.
Before initial startup, please make sure to take notice of the information
regarding the intended use in the enclosed installation guide!
Operate the device only with a professionally installed power supply at a
nearby power socket that is freely accessible at all times.
Please observe the following when setting up the device
→The power plug of the device must be freely accessible.
→ For devices to be operated on the desktop, please attach the adhesive rubber
footpads
→Do not rest any objects on top of the device
→Keep all ventilation slots on the side of the device clear of obstruction
→In case of wall mounting, use the drilling template as supplied
→Rack installation with the optional LANCOM Rack Mount (separately available)
LED description & technical details
Mounting & connecting
➀ Power
Off | Device switched off |
---|---|
Green, permanently* | Device operational, resp. the device paired/claimed and |
LANCOM Management Cloud (LMC) is accessible
Red / green blinking| Configuration password not set. Without a configuration
password, the configuration data in the device is unprotected.
Red blinking| Charge or time limit reached
1x green inverse blinking| connection to the LMC active, pairing OK, device
not claimed
2x green inverse blinking| Pairing error, resp. LMC activation code not
available
3x green inverse blinking*| LMC not accessible, resp. communication error
➁ Online
Off | Interface deactivated |
---|---|
Orange, blinking | Synchronization with the modem |
Orange, permanently | Synchronization with the modem successful |
Green, permanently | WAN connection established |
Green, flickering | WAN data transmission |
Red/orange, blinking | Hardware error, ext. modem |
➃ ETH
Off | No networking device attached |
---|---|
Green, permanently | Connection to network device operational, no data traffic |
Green, flickering | Data transmission |
➄ 4G
Off | Cellular interface disabled |
---|---|
Green, permanently | Connection to cellular network active |
Green, flickering | Cellular data transfer |
Orange, permanently | Logon to cellular network successful |
Orange, blinking | Logging on to cellular network |
Red, permanently | Hardware error/module unavailable |
Red / green, blinking | SIM card error (PIN) |
Red/orange, blinking | Uploading module firmware |
➅ VPN
Off | VPN connection inactive |
---|---|
Green, permanently | VPN connection active |
Green, flashing | VPN connecting |
➆ Reset
Reset button| Operated e.g. with a paper clip short press: Restart the device
long press: Reset the device
---|---
Hardware
Power supply| 12 V DC, external power adapter (230 V); bayonet connector to
secure against disconnection
---|---
Power consumption| Max. ca. 9 W
Environment| Temperature range 0–40 °C; humidity 0–95 %; non-condensing
Housing| Robust synthetic housing, rear connectors, ready for wall mounting,
Kensington lock; measures 210 x 45 x 140 mm (W x H x D)
Number of fans| 1 quiet fan
Interfaces
4G: Ant 1, Ant 2| Two SMA connectors for the supplied dipole rod antennas
(LTE, UMTS), are compatible LANCOM AirLancer antennas for 4G or 3G, or from
other manufacturers. Please respect the restrictions which apply in your
country when setting up an antenna system (in particular the antenna gain and
transmission power).
---|---
WAN| 10 / 100 / 1000 Mbps Gigabit Ethernet
ETH| 3 individual 10 / 100 / 1000 Mbps Gigabit Ethernet ports; ex-factory
operation as a switch. The ports can be electrically disabled in the LCOS
configuration and support energy-saving functionality as per IEEE 802.3az.
USB| USB 2.0 hi-speed host port for connecting USB printers (USB print
server), serial devices (COM-port server) or USB drives (FAT file system)
Config (Com) / V.24| Serial configuration interface/COM-port (8-pin mini-DIN):
9,600 – 115,200 baud, suitable for optional connection of analog/GPRS modems.
Supports internal COM-port server and provides transparent asynchronous
serial-data transfer via TCP.
WAN protocols
Ethernet| PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE
(with or without DHCP), RIP-1, RIP-2, VLAN
---|---
Package content
Cable | 1 Ethernet cable, 3 m (kiwi colored connectors) |
---|---|
Antennas | 2 LTE / 4G antennas |
Power adapter | External power adapter, 12 V / 2 A DC/S, barrel connector 2.1 / |
5.5 mm bayonet, LANCOM item no. 111303 (not for WW devices)
*) The additional power LED statuses are displayed in a 5-second rotation if the device is configured to be managed by the LANCOM Management Cloud.
This product contains separate open-source software components which are
subject to their own licenses, in particular the General Public License (GPL).
The license information for the device firmware (LCOS) is available on the
device‘s WEBconfig interface under “Extras > License information“. If the
respective license demands, the source files for the corresponding software
components will be made available on a download server upon request.
Hereby, LANCOM Systems GmbH | Adenauerstrasse 20/B2 | D-52146 Wuerselen,
declares that this device is in compliance with Directives 2014/30/EU,
2014/53/EU, 2014/35/EU, 2011/65/EU, and Regulation (EC) No. 1907/2006. The
full text of the EU Declaration of Conformity is available at the following
Internet address:
www.lancom-systems.com/doc
LANCOM, LANCOM Systems, LCOS, LAN community, and Hyper Integration are registered trademarks. All other names or descriptions used may be trademarks or registered trademarks of their owners. This document contains statements relating to future products and their attributes. LANCOM Systems reserves the right to change these without notice. No liability for technical errors and/or omissions. 111956/0622
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>