**** DECKENVENTILATOR CEILING FAN
CLASSIC ROYAL 180
CLASSIC ROYAL 132
CLASSIC ROYAL 103
CLASSIC ROYAL 75
BLACK MAGIC
About this operating manual
Before using the CasaFan fan, read the mounting and operating manual
carefully. For the safety of persons it is important to follow these
instructions!
Explanation of symbols:
WARNING: Electric voltage! Warns you of immediate danger to life.
ATTENTION:
Indicates risks to health and possible damage to property.
With electrical devices, there is a danger to life from electric shock if used
improperly, installed incorrectly or if the safety instructions are not
observed!
SAFETY ADVICES
– Keep the operating manual within reach. Never pass the fan onto another
person without the operating manual.
– This ceiling fan is for circulating dry room air. Their use in machines,
outside, in garages, in moist or wet rooms or rooms in danger of fire or
explosion, is not permitted.
– This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understands the hazards
involved.
– Cleaning and user maintenance shall not be made by children without
supervision.
– If unusual oscillating movement is observed, immediately stop using the
ceiling fan and contact the manufacturer, its service agent or suitably
qualified persons.
– Replacement of parts of the safety suspension system device shall be
performed by the manufacturer, its service agent or suitably qualified
persons.
– Mounting of the suspension system shall be performed by the manufacturer,
its service agent or suitably qualified persons.
– Before accessing the connection and installation, the current must be
disconnected on all poles (fuse in fuse box).
– Children shall not play with the appliance.
– Ensure that the fan is switched off from the supply mains before service and
maintenance.
– The electrical connection and electrical maintenance of this fan may only be
carried out by a trained electrician, a skilled electrician or an
appropriately qualified person.
– The voltage details on the rating label are to conform with the available
mains voltage.
– Do not run the cables over sharp edges and under no circumstances squeeze
the cables during installation.
– Only operate the ceiling fan when completely assembled!
– WARNING! The mains connection requires a two-pole isolating switch with
a contact opening width of at least 3 mm. The disconnecting device must be
integrated into the
fixed wiring according to the valid technical regulations.
– The electrical safety of the fan is only guaranteed if the earthing system
of the building installation is installed in accordance with the regulations
and the fan is connected to it.
– The mains connection to which the fan is connected must comply with the
applicable local standards.
– Choose a safe place for installation and make sure that there are no objects
within the area of rotation.
– The construction and fixture of the holder and ceiling is to be able to bear
4 times the weight of the fan when being moved.
– None of the fan blades are to be less than 2.3 m from the ground.
– Keep the fan away from heat sources. The minimum distance to radiant heaters
and stoves is 1.5 m.
– Before first using after the setup, all electrical and mechanical
connections are to be checked in order to prevent any fall, fire or electric
shock.
Observe notes on disposal!
Our ceiling fans are quality products and designed for a long service
life.
– Do not dispose of a appliance at the end of its service life and any
batteries required to operate the appliance in household waste!
– Find out about local return and recycling possibilities and use the existing
collection points in your area for disposal.
– Dispose of packaging material that is no longer required in an
environmentally friendly manner and inaccessible to children.
– There is a risk of suffocation for children by inhaling or swallowing parts
of the packaging.
PARTS (Figure U, page 28)
Unpack the fan and compare the package contents for completeness. All the
parts shown in the figure are to be present and undamaged.
Technical data:
Type| ROYAL 132/180
BLACK MAGIC 132| ROYAL 103| ROYAL 75
---|---|---|---
Mains voltage| 220 – 240 V
Frequency| 50 Hz
Power motor (W)| 64/66 (max.)| 153 Watt (max.)| I 49 Watt (max.)
Protection clas| 1/1P20
No. of speeds| 3
Dimensions 0 x H (mm)| appr.1320/1800 x 410
appr.1320 x 410| appr. 1050 x 410| appr. 770 x 410
Distance ceiling — blades| appr. 300 mm, or appr. 210 mm
Weight (kg)| appr. 7.4 1| appr. 6.1| I appr. 4.9
Subject to technical modifications.
CLASSIC ROYAL – BLACK MAGIC
PARTS
1 | Hanger Bracket |
---|---|
2 | Terminal Block |
3 | Canopy Screw (4×) |
4 | Safety Rope |
5 | Fan Wire |
6 | Canopy |
7 | Canopy Screw Cover |
8 | Downrod and Hanger Ball |
9 | Downrod Support |
10 | Downrod Support Screw (2×) |
11 | Clevis Pin |
12 | Hairpin Clip |
13 | Motor Assembly |
14 | Upper Cover |
15 | Blade (5×) |
16 | Bladeholder (5×) |
17 | Mounting ring for low profile installation |
18 | Blade Screws (15×) |
19 | Bladeholder Screws (10×) |
20 | Bracket Screw for Wood (2×) |
21 | Support Safety Rope |
22 | Balancing kit |
23 | Transport lock (3×) |
WARNING: Danger of electric shock! Before commencing installation, turn
off electricity supply at the main power box or disconnect power by removing
fuse.
ATTENTION : Follow all installation directions. Improper installation can
lead to injuries and material damage.
– The place of installation (ceiling) must have a load capacity of at least 30
kg.
– Use only for your type of ceiling suitable screws and plugs (not supplied).
- Attach the hanger1 bracket with 2 screws. Tighten the screws.
- Fasten the hook 21for the safety rope on the ceiling as shown.
- Unscrew 1 canopy screw 3 on each side and put it aside.
Remove the 3
transport locks**23**
on the motor before starting assembly.
Decide on installation with downrod **A**
or without downrod for low
ceilings**B**
.
NOTE:**B**
not suitable for CLASSIC ROYAL 180!![CasaFan 518003 Ceiling Fan
- fig 9](https://manuals.plus/wp-content/uploads/2023/01/CasaFan-518003 -Ceiling-Fan-fig-9.png) Uninstall the clevis pin from the downrod, retain the clevis pin and hairpin clip for later. Install the canopy, cover ring and upper cover through downrod.
Unscrew the two screws at the downrod support at the motor.
- Insert the downrod into the support.
- Insert the clevis pin through the opening provided and
- secure it with the hairpin clip.
- Tighten the two screws on the downrod support.
Hang the pre-mounted ceiling fan into the ceiling bracket. Hang the safety cable in the hook provided for this purpose and pull it tightly downwards to secure it against leaking. Make the electrical connection as shown on page 45
Slide the canopy up and twist it into the bayonet lock with the canopy screws. Fasten the 4 canopy screws. Press the cover ring upwards until it clicks into place.Not suitable for CLASSIC ROYAL 180 or palm blades
- Remove the canopy cover from the canopy.
- Unscrew 3 screws (staggered at 120°) from the motor at the mounting of the downrod.
Place the mounting ring and the canopy over the down rod support so that the 3 screws on the motor protrude through the 3 larger holes in the canopy and the mounting ring. Screw the mounting ring with canopy onto the motor with the 3 screws you removed earlier
- Feed the safety rope over the hook and tighten it firmly. Make the electrical connection as shown on page 45.
- Slide the canopy up and twist it into the bayonet lock wit h the canopy screws. Fasten the 4 canopy screws.
Attach the 5 blade 16 holders to the blades with 3 blade screws 18
each.
Electrical connections 220-240 ****50Hz
Mains electrical
**| green/yellow|
---|---|---
N| blue|
L**| brown|
– Connect the cables with the mains voltage to the terminal block.
– Plug the two connectors together to provide power to the motor.
- Attach the 5 blade holders to the motor with 2 blade holder screws 19 each.
- Mount the pull chain – Your ceiling fan is now ready to run for the first time.
Mounting luminaire (BLACK MAGIC)
Operation
NOTES FOR REMOVING FAULTS
Fault | Remedy |
---|---|
The fan does not start | – Check the fuses/trips at the main box and other |
connections.
– Check the fan connection to the mains.
– Repeat coding of the fan with the handheld transmitter.
– Replace the battery in the handheld transmitter if necessary.
The fan is noisy| – Check that all bolts and screws have been tightened.
– Run in the fan and the bearings for 24 hours. Most noises disappear after
this
time.
The fan vibratestoo much|
– All blades have been weighed and grouped according to weight. Their density
can vary and therefore cause vibration even when all blades are of the same
weight. The following methods can contribute to preventing most vibrations.
Check the vibration before each procedure. Please note that a small amount of
vibration is normal and does not pose a
problem.
– Most vibrations occur when one of the blades is not in alignment with the
others. Aligning the blades is simply carried out with the aid of a flat
ruler. Place the ruler vertically upwards against the ceiling and alongside
the blade tip. Mark the distance between the blade side and ceiling. Turn the
blades slowly by hand and carry out the
same measurements with the other blades. If one of the blades is not correctly
aligned, it can be remedied by lightly pressing their holders upwards or
downwards in order to align them with the others.
– Check that the hanger bracket is firmly anchored to the ceiling.
Important: Opening up and repairing the unit may only be carried out by a qualified electrician!
CLEANING/MAINTENANCE
WARNING: Danger of electric shock! Turn off the electricity at the fuse
box or circuit breaker before cleaning or servicing your fan.
– Never use water for cleaning your ceiling fan. The appliance must not get
wet.
– Do not use petrol or any similar light flammable detergents!
– Clean the surface of the housing and the blades with a dry cleaning cloth.
Regular check
– Check twice a year all the screws, especially those of the ceiling
suspension, for tightness, retighten if necessary.
– Check electrical connections for proper connection.
– Greasing the bearings is not necessary, the bearings are permanently
lubricated.
Shorten the down rod
- Mark length.
- Saw off the rod.
- Drill a hole.
- Deburr the cut edge and the hole.
Use balancing kit (Figure C)
The balancing kit contains 2 weights 1 at 5 grams each as well as a blade
clip 2 with 5 grams weight. If your ceiling fan is running after accurate
and complete installation unbalanced (“wobbling”), please follow step 1 to 6:
- Switch your ceiling fan on and find out the speed setting at which the wobble is the greatest.
- Turn off your ceiling fan and allow it to come to a complete stop. Select one blade and place the balance clip on it, halfway between the bladeholder and the blade tip on the trailing edge of the blade.
- Turn the fan on and select the speed setting at which the wobble was greatest. Note whether the wobble has increased or decreased. Turn the fan off, move the clip to the next blade and retest. Repeat this procedure on all blades noting the blades on which the greatest improvement is achieved.
- Move the clip back to the blade that showed the greatest improvement. Move the clip inward and outward on this blade and operate the fan to find the position where the clip gives the greatest improvement.
- Remove the clip and glue the balancing weight on top of the blade along the centerline at the point where the clip was positioned.
- If the fan wobble problem has not been corrected finally you can improve the balancing further by repeat the procedure with additional weights.
DISPOSAL
– Never dispose of the appliance in normal household waste.
For appliances with the adjacent symbol, use the local collection points for
the return of old electrical appliances in accordance with the European
Directive WEEE, 2012/19/EU. For information on how to return waste electrical
and electronic equipment free of charge, please contact your local authority.
By disposing of them separately, you are making your contribution to recycling
raw materials and protecting the environment.
Matching luminaires
CasaFan reserves the right to make any changes to the product without prior notice.
CasaFan GmbH Senefelderstr.
8 63594 Hasselroth * Germany
© CasaFan 2022