CasaFan Eco Genuino-L Ceiling Fan Instruction Manual

June 1, 2024
CasaFan

CasaFan Eco Genuino-L Ceiling Fan

CasaFan-Eco-Genuino-L-Ceiling-Fan-Product

About this operating manual
Before using the Caspian fan, read the mounting and operating manual carefully. For the safety of persons, it is important to follow these instructions!

Explanation of symbols:

  WARNING: Electric voltage!|   ATTENTION:
Warns you of immediate danger to life.| Indicates risks to health and possible property damage.
With electrical devices, there is a danger to life from electric shock if used improperly, installed incorrectly or if the safety instructions are not observed!

SAFETY ADVICE

  • Keep the operating manual within reach. Never pass the fan onto another person without the operating manual.
  • This ceiling fan is for circulating dry room air. Their use in ma-chines, outside, in garages, in moist or wet rooms or rooms in danger of fire or explosion, is not permitted.
  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
  • Cleaning and user maintenance shall not be done by children without supervision.
  • If unusual oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent or suitably qualified persons.
  • Replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent or suitably qualified persons.
  • Mounting of the suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons.
  • Before accessing the connection and installation, the current must be disconnected on all poles (fuse in fuse box).
  • Children shall not play with the appliance.
  • Ensure that the fan is switched off from the supply mains before service and maintenance.
  • The electrical connection and electrical maintenance of this fan may only be carried out by a trained electrician, a skilled electrician or an appropriately qualified person.
  • The voltage details on the rating label are to conform with the available mains voltage.
  • Do not run the cables over sharp edges and under no circumstances squeeze the cables during installation.
  • Only operate the ceiling fan when completely assembled!
  • WARNING! The mains connection requires a two-pole isolating switch with a contact opening width of at least 3 mm. The dis-connecting device must be integrated into the fixed wiring accor-ding to the valid technical regulations.
  • The electrical safety of the fan is only guaranteed if the earthing system of the building installation is installed by the regulations and the fan is connected to it.
  • The mains connection to which the fan is connected must comply with the applicable local standards.
  • Choose a safe place for installation and make sure that there are no objects within the area of rotation.
  • The construction and fixture of the holder and ceiling is to be able to bear 5 times the weight of the fan when being moved.
  • None of the fan blades are to be less than 2.3 m from the ground.
  • Keep the fan away from heat sources. The minimum distance to radiant heaters and stoves is 1.5 m.
  • Before first using after the setup, all electrical and mechanical connections are to be checked to prevent any fall, fire or electric shock.

Caution

CasaFan-Eco-Genuino-L-Ceiling-Fan-Fig-1

Our ceiling fans are quality products and designed for a long service life.

  • Do not dispose of an appliance at the end of its service life and any batteries required to operate the appliance in household waste!
  • Find out about local return and recycling possibilities and use the existing collection points in your area for disposal.
  • Dispose of packaging material that is no longer required in an envi-ronmentally friendly manner and inaccessible to children.
  • There is a risk of suffocation for children by inhaling or swallowing parts of the packaging.

PARTS

Unpack the fan and compare the package contents for completeness. All the parts shown in the figure are to be present and undamaged.

ECO GENUINO-L

CasaFan-Eco-Genuino-L-Ceiling-Fan-Fig-2

  1. Hanger Bracket
  2. Canopy Screw (4×) Terminal Block
  3. Canopy
  4. Canopy Ring
  5. Down Rod and Hanger Ball
  6. Clevis Pin
  7. Hairpin Clip
  8. Motor Coupling Cover
  9. Blade support (3×)
  10. Blade support screws (6×)
  11. Downrod Support Screw (2×)
  12. Motor Assembly
  13. Light kit support
  14. LED unit
  15. Light kit glass
  16. Blade (3×)
  17. Blade Screw (6×)
  18. Bushing blade screw (6×)
  19. Receiver remote control
  20. Remote Control
  21. a Lag Bolt (2×)
  22. b Machine Screw M5 (2×)
  23. c Flat Washer (2×)
  24. d Spring Washer(2×)
  25. Hook for safety rope
  26. Safety rope

CasaFan-Eco-Genuino-L-Ceiling-Fan-Fig-3

Technical Data

Technical data:

Type| Eco Genuino-L 122| Eco Genuino-L 152
Mains voltage| 220 – 240 V ~ 50 Hz
Power motor| 3.5 – 12 W| 3.5 – 17 W
Power light kit| 17 W (max.)
Protection class| I/IP20
No of speeds| 6 (with remote control)
Dimensions Ø × H| 1220 × 360 (280) mm| 1520 × 360 (285) mm
Dist. ceiling – blades| 1220 × 420 (320) mm| 1520 × 420 (320) mm
Weight| 390 (290) mm| 390 (290) mm
Light kit| This product contains an energy efficiency class F light source
Service interval| once a year
Subject to technical modifications.

Downrod reduced to 100 mm height (smallest possible height).

Installation ceiling bracket

WARNING:
The danger of electric shock! Before commencing installation, turn off the electricity supply at the main power box or disconnect the power by removing the fuse.

CasaFan-Eco-Genuino-L-Ceiling-Fan-Fig-4

ATTENTION:
Follow all installation directions. Improper installation can lead to injuries and material damage.

  • The place of installation (ceiling) must have a load capacity of at least 45 kg.
  • Use only for your type of ceiling suitable screws and plugs (not supplied).
  1. Attach the hanger bracket 1 with 2 screws and washers. Tighten the screws.
  2. Fasten the hook 23 for the safety rope on the ceiling as shown.
  3. Pre-install two canopy screws 2 on the opposite sides of the hanger bracket. Do not tighten!

Assembling

  • fig 4: Attach the blade brackets to the 3 blades with the blade screws and the bushes of the blade screws.
  • fig. 5: Flip the motor assembly over. Remove one of the 3 screws and keep it for later installation. Partially loosen the other two screws.
  • fig. 6: Place the light support on the motor and turn it into the bayonet opening. Insert the previously removed screw A. Tighten all 3 screws.CasaFan-Eco-Genuino-L-Ceiling-Fan-Fig-7
  • fig. 7: Place the motor assembly on a flat area. Secure the blade supports to the top of the motor with the blade support screws. Make sure the side with the “this side up” sticker is installed upward. Mount all 3 blades in this way.
  • Flip the motor assembly upside down again. Loosen the screw B on the lamp holder. Plug the plugs of the cables of the LED light together until they snap into place.CasaFan-Eco-Genuino-L-Ceiling-Fan-Fig-9
  • Insert the LED unit into the lamp holder, twist it in the bayonet and secure it with screw B. Take care not to crush or damage any cables. Tighten the 3 screws.CasaFan-Eco-Genuino-L-Ceiling-Fan-Fig-10
  • Remove the hanger ball C from the downrod by loosening screw A. Remove the locking pin B as well as the locking pin D and the hairpin pin E.
  • Loosen the two upper screws F on the bracket for the downrod. Feed all the motor cables through the downrod and place the downrod in the bracket. Insert the locking pin D through the hole in the bracket and the downrod. Secure the locking pin with the split E. Tighten the two upper screws F to lock the rod.CasaFan-Eco-Genuino-L-Ceiling-Fan-Fig-11
  • Place the coupling cover, the canopy ring and the canopy on the downrod in this order.
  • Now mount the hanger ball A on the ceiling bar. Proceed in reverse order as shown in figure 12.CasaFan-Eco-Genuino-L-Ceiling-Fan-Fig-13
  • Hang the pre-assembled ceiling fan in the ceiling bracket. Feed the safety rope over the hook and tighten it firmly. The „nose“ in the holder for the hanger ball (A) must engage in the loop in the hemisphere (B)!CasaFan-Eco-Genuino-L-Ceiling-Fan-Fig-14
  • Place the receiver of the remote control as shown in the figure in the ceiling bracket.CasaFan-Eco-Genuino-L-Ceiling-Fan-Fig-15

Electrical connections

Connect the plugs as shown in the picture fig. 12 and connect the mains voltage at the terminal block 2.

CasaFan-Eco-Genuino-L-Ceiling-Fan-Fig-16

A green/yellow
B blue
C brown
D purple
E red
F orange

Slide the canopy up to the mounting bracket and place the keyhole slots on the canopy over the two screws on the mounting bracket. Rotate the canopy 4 until the screw head locks in place. Re-tighten the 2 screws and reinstall the other 2 screws. Install the canopy ring 5 by pushing it up to the canopy.CasaFan-
Eco-Genuino-L-Ceiling-Fan-Fig-17

Insert the lamp glass into the lamp holder. The „noses“ (A) in the lamp holder must engage in the grooves (B) in the glass. Rotate the lamp glass as shown in the illustration fig. 16 until it is firmly seated.

INITIAL OPERATION

NOTE:
Always when the ceiling fan is started, the motor will “search” for its start position. Depending on the motor position, the motor will need to briefly move forward and then backward, which is completely normal.

  • Insert 2 batteries type AAA (1.5V) into the transmitter of the remote control.

Coding remote control

Recoding/Connect
Set both DIP switches in the UPPER position.

  • The coding is completed.

Your ceiling fan and the remote control are ready for use after switching on the power supply. Multiple remote control handpieces with the same setting can control the same ceiling fan.

Set both DIP switches in the LOWER position.

Turn on the power. Within 60 seconds, press the „SET“ button for 5 to 10 seconds until a „Beep“ for confirmation sounds.

  • Your ceiling fan and remote control are ready for use. Use this mode to control several ceiling fans each with assigned remote control.

Operation

CasaFan-Eco-Genuino-L-Ceiling-Fan-Fig-21

1 LED-Anzeige Ventilator EIN/AUS LED indication Fan ON/OFF
2 LED-Anzeige Stufe 1 – 6 LED indication Speed 1 – 6
3 + 1 Stufe schneller + 1 Speed faster
4 – 1 Stufe langsamer – 1 Speed slower
5 Motor AUS Motor OFF
6 Wechsel Drehrichtung Forward/ Reverse
7 Leuchte EIN/AUS Light ON/OFF
Licht dimmen > 2 Sekunden Dim the light > 2 seconds

Troubleshooting

NOTES FOR REMOVING FAULTS

Fault| Remedy
The fan does not start| –   Check the fuses/trips at the main box and other connections.

–   Check the fan connection to the mains.

–   Repeat coding of the fan with the handheld transmitter.

–   Replace the battery in the handheld transmitter if necessary.

The fan is noisy| –   Check that all bolts and screws have been tightened.

–   Run in the fan and the bearings for 24 hours. Most noises disappear after this time.

The fan vibrates too much| –   All screws during assembly of the ventilator, especially those relating to the axis, have an important function. Not tightened screws are the main cause of imbalances. Please make sure that all screws are tightened.

–   All blades have been weighed and grouped according to weight. Wood is a natural material. Their density can vary and therefore cause vibration even when all blades are of the same weight. If the blade screws of one of the blades are not tightened properly, this could cause massive wobbling.

NOTE: Movement of up to 10 mm is quite acceptable and does not mean a faulty ceiling fan.

–   Check that the hanger bracket is firmly anchored to the ceiling.

Important:

Opening up and repairing the unit may only be carried out by a qualified electrician!

CLEANING/MAINTENANCE

WARNING:
The danger of electric shock! Turn off the electricity at the fuse box or circuit breaker before cleaning or servicing your fan.

  • Never use water for cleaning your ceiling fan. The appliance must not get wet.
  • Do not use petrol or any similar light flammable detergents!
  • Clean the surface of the housing and the blades with a dry cleaning cloth.

Regular check

  • Check once a year all the screws, especially those of the ceiling suspension, for tightness, and retighten if necessary.
  • Check electrical connections for proper connection.

DISPOSAL

The packaging is made of environmentally friendly materials that you can dispose of at local recycling points.

  • The labelling of packaging materials helps with waste separation, these are marked with abbreviations (a) and numbers (b). These have the following meaning: 1 – 6 = plastics / 20 – 22 = paper and cardboard / 80 – 99 = composites.
  • The product and packaging materials are recyclable, dispose of them separately for better waste treatment. The Triman logo is only valid for France.
  • Do not throw electrical appliances and portable batteries in the household waste!
  • According to the European Directive 2012/19/EU on waste electrical and electronic equipment and its implementation in national law, used electrical equipment and waste batteries must be collected separately and recycled in an environmentally sound manner.

In the interest of environmental protection, do not dispose of the product in household waste, but recycle it pro-perly. You can obtain information about collection points from your specialist dealer or your local administration.

Declaration Of Conformity

We, the company

CasaFan GmbH
Senefelderstr. 8 Hasselroth, 63594, Germany.

declare under our sole responsibility that the following product

  • type of product: ceiling fan
  • trademark: CasaFan
  • model article-no further details
  • Eco Genuino-L #315261, 315260, 315276, 315275, 315266, 315265, 315271, 315270 #312261,312260, 312276, 312275, 312266, 312265, 312271,312270 #399920, 399923, 39921, 399922
  • LED Modul ML095A-1

meets the essential requirements of the following EU-Directives:

  • 2014/53/EC Radio Equipment Directive (RED)
  • 2011/65/EC Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment
  • 2009/125/EC Ecodesign directive

Applied standards and regulations:

  • EN 60335-1:2012+A11:2014+A13:2017
  • EN 60335-2-80:2003+A1:2004+A2:2009
  • EN 62233:2008
  • EN 55014-1:2017
  • EN 55015:2015
  • EN 61000-3-2:2019
  • EN 61000-3-3:2013/A1:2019
  • EN 61000-4-2:2009

The person for technical documentation:

Name, Position:
Stephan Willemsen, Geschäftsführer/managing director

Hasselroth, 21.03.2023
…………………………….
Datum/ Date

CasaFan reserves the right to make any changes to the product without prior notice.

CasaFan GmbH Senefelderstr. 8 63594 Hasselroth * Germany. © CasaFan 2024.