Product Specifications
Product Specifications
Model No.| HV9658-12V60WS| HV9658-24V60WS| HV9658-12V95WS| HV9658-24V95WS
Material| Aluminium
IP Rating| IP66
Protection Class| 1(Requires Earth)
Input Voltage| 240v AC
Output Voltage| 12v DC| 24v DC| 12v DC| 24v DC
Total Load| 60W| 60W| 95W| 95W
Recommended Total Load| 48W| 76W
Wiring| Parallel
Dimmable| No
Operating Temperature| -25° – + 50°
Protections| Overload, Over Voltage, Over Temperature & Short Circuit
Warranty| 3 Years Replacement*
Dimensions
Important Safety Issues
- This product must be installed by a qualified electrician according to AS/NZS 3000.
- Ensure all electrical mains are disconnected before any installation.
- Modification of this product will void any warranty.
- Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system.
- Aluminium and 304SS fittings must not be installed within 5km of any salt water environments.
- All Havit Lighting LED Drivers are provide with a flex & plug for ease of replacement if Driver was to fail. Removing this plug will void warranty.
- The converter must only be connected by a fully qualified electrician.
- Make sure has the correct output voltage to light source being installed.
- The installer is responsible for proper installation according to safety regulations. The primary and secondary cables have to be selected considering type and wire gauge.
- Load, cable length, voltage drop and terminal characteristics have to be taken into consideration.
- Disconnect the LED Driver from the main power if its cables are damaged. – Damaged cables must be replaced.
- LED Driver can become very hot during use, Do not cover.
- The distance between the power supplies and the surfaces around must be min. 50mm so Driver is well ventilated.
- The power supply has connection cables on primary and secondary side. The secondary cables are multiple depending of the power class and are connected to the same potential. The load has to be divided to the connection cables equally. It is not permitted to take the complete load by one single output cable, alternatively you can parallel the 2x output cables to have full power from one connection point.
- This form may be updated at any time due to product improvements, please check online installation form for most current version.
Steps for Installation
- Connect the Output cable to light source making sure that polarity is correct. If Driver has 2x Output cables, These can be joined to form one connection point.
- If connections are outdoors make sure to cover connections using an adhesive lined heat shrink or gel cap to make connection watertight. Failure to do this will void warranty.
- Make sure power is off before connecting 240v plug to power point, Once plugged in turn power back on.
- When LED Driver is turned on and a ticking noise can be heard. This indicates a short on the run. Turn Driver off and inspect all connections before turning back on.
Must be installed by a licensed electrician