Model 508940 (IPIK-60G)
Important: Read before use.
508940 Industrial Gigabit PoE++ Splitter
For additional benefits: Scan to register your product warranty or go to: register.intellinet-network.com/r/508940
Instructions
This guide presents the basic steps to set up and operate this device.
For specifications, visit
intellinetnetwork.com.
Register your product at register.intellinet-
network.com/r/508940 or scan
the QR code on the cover.
Connections
- Wire the grounding terminal to an earth grounding object to protect equipment from external electrical surges.
- Connect Ethernet cable (min. Cat5e) from a PSE port on a PoE source (up to 60 W input; IEEE 802.3bt/at/af-compliant) to the PoE IN port on the splitter. The PWR LED lights to indicate a powered connection to PSE.
- Connect Ethernet cable (min. Cat5e) from the DATA port on the splitter to an RJ45 port on a network device.
- Connect an appropriate cable from one of the DC OUT ports (either the terminal block or the power jack; output up to 12 V / 4.25 A / 51 W) on the splitter to the network device or other device you wish to power.
Terminal Block Installation
Note: Ensure all power is off/disconnected before beginning! The wire
gauge for the terminal block should be in the range between 12 – 24 AWG.
4-1 Loosen appropriate screws. Insert bare power-supply wires into appropriate
terminal slots (positive wire into positive slot; negative wire into negative
slot, etc.).
4-2 Tighten appropriate screws to secure wires.
4-3 Install block into the device.
Placement
Desktop Installation
Prior to use, place/position the device:
- on a level surface that can support its weight and has at least 25 mm (approx. 1”) of clearance for ventilation;
- away from sources of electrical noise: radios, transmitters, broadband amplifiers;
- within 100 m (approx. 328’) of network devices it’s to be connected to.
DIN-Rail Installation
- Angle spring of mounting clip over top lip of DIN rail.
- Push device down till clip clicks onto rail.
- Ensure installation is stable.
WASTE ELECTRICAL & ELECTRONIC EQUIPMENT
DISPOSAL OF ELECTRIC AND ELECTRONIC EQUIPMENT
(Applicable In The European Union And Other European Countries With Separate
Collection Systems)
This symbol on the product or its packaging means that this product must not
be treated as unsorted household waste. In accordance with EU Directive
2012/19/EU on Waste Electrical and Electronic Equipment (WEEE), this
electrical product must be disposed of in accordance with the user’s local
regulations for electrical or electronic waste. Please dispose of this product
by returning it to your local point of sale or recycling pickup point in your
municipality.
WARRANTY AT : intellinetnetwork.com
REGULATORY STATEMENTS
FCC Class A
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the Federal Communications Commission
(FCC) Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency
energy, and if not installed and used in accordance with the instruction
manual may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference,
in which case the user will be required to correct the interference at his own
expense. Any changes or modifications made to this equipment without the
approval of the manuafacturer could result in the product not meeting the
Class A limits, in which case the FCC could void the user’s authority to
operate the equipment.
CE : This device complies with the requirements of CE 2014/30/EU and / or
2014/35/EU. The Declaration of Conformity for is available at:
support.intellinet-network.com/barcode/508940
North America
IC Intracom America
550 Commerce Blvd.
Oldsmar, FL 34677 USA| Asia & Africa
IC Intracom Asia
4-F, No. 77, Sec. 1, Xintai 5th Rd.
Xizhi Dist., New Taipei City 221, Taiwan| Europe
IC Intracom Europe
Löhbacher Str. 7, D-58553
Halver, Germany
intellinetnetwork.com
All trademarks and trade names are the property of their respective owners.
© IC Intracom. All rights reserved.
Intellinet Network Solutions is a trademark of IC
Intracom, registered in the U.S. and other countries.
**** Printed on recycled paper.
INT_508940_QIG_0222_REV_5.11
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>