Connections

INTELLINET 508940 Industrial Gigabit PoE - fig 2

  1. Wire the grounding terminal to an earth grounding object to protect equipment from external electrical surges.
  2. Connect Ethernet cable (min. Cat5e) from a PSE port on a PoE source (up to 60 W input; IEEE 802.3bt/at/af-compliant) to the PoE IN port on the splitter. The PWR LED lights to indicate a powered connection to PSE.
  3. Connect Ethernet cable (min. Cat5e) from the DATA port on the splitter to an RJ45 port on a network device.
  4. Connect an appropriate cable from one of the DC OUT ports (either the terminal block or the power jack; output up to 12 V / 4.25 A / 51 W) on the splitter to the network device or other device you wish to power.

Terminal Block Installation

Note: Ensure all power is off/disconnected before beginning! The wire gauge for the terminal block should be in the range between 12 – 24 AWG.
4-1 Loosen appropriate screws. Insert bare power-supply wires into appropriate terminal slots (positive wire into positive slot; negative wire into negative slot, etc.).
4-2 Tighten appropriate screws to secure wires.
4-3 Install block into the device.

Placement

Desktop Installation
Prior to use, place/position the device:

  • on a level surface that can support its weight and has at least 25 mm (approx. 1”) of clearance for ventilation;
  • away from sources of electrical noise: radios, transmitters, broadband amplifiers;
  • within 100 m (approx. 328’) of network devices it’s to be connected to.

DIN-Rail Installation

  1. Angle spring of mounting clip over top lip of DIN rail.
  2. Push device down till clip clicks onto rail.
  3. Ensure installation is stable.

INTELLINET 508940 Industrial Gigabit PoE - fig 1

WASTE ELECTRICAL & ELECTRONIC EQUIPMENT
DISPOSAL OF ELECTRIC AND ELECTRONIC EQUIPMENT
(Applicable In The European Union And Other European Countries With Separate Collection Systems)
This symbol on the product or its packaging means that this product must not be treated as unsorted household waste. In accordance with EU Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE), this electrical product must be disposed of in accordance with the user’s local regulations for electrical or electronic waste. Please dispose of this product by returning it to your local point of sale or recycling pickup point in your municipality.
WARRANTY AT : intellinetnetwork.com

REGULATORY STATEMENTS

FCC Class A
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the Federal Communications Commission (FCC) Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Any changes or modifications made to this equipment without the approval of the manuafacturer could result in the product not meeting the Class A limits, in which case the FCC could void the user’s authority to operate the equipment.
CE : This device complies with the requirements of CE 2014/30/EU and / or 2014/35/EU. The Declaration of Conformity for is available at:
support.intellinet-network.com/barcode/508940


North America
IC Intracom America
550 Commerce Blvd.
Oldsmar, FL 34677 USA| Asia & Africa
IC Intracom Asia
4-F, No. 77, Sec. 1, Xintai 5th Rd.
Xizhi Dist., New Taipei City 221, Taiwan| Europe
IC Intracom Europe
Löhbacher Str. 7, D-58553
Halver, Germany

intellinetnetwork.com
All trademarks and trade names are the property of their respective owners.
© IC Intracom. All rights reserved.
Intellinet Network Solutions is a trademark of IC
Intracom, registered in the U.S. and other countries.
**** Printed on recycled paper.
INT_508940_QIG_0222_REV_5.11

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

INTELLINET User Manuals

Related Manuals