LINORTEK NETBELL-NTG-W External Trigger User Manual

June 2, 2024
LINORTEK

LINORTEK NETBELL-NTG-W External Trigger

LINORTEK NETBELL-NTG-W External Trigger

You may program your NetbellNTG to play a tone upon input from an external trigger such as a pushbutton or door contact switch.

Note: unless your trigger device supplies its own power, ensure your input switch is set to Pull UP (PU) (See Wiring the NetbellNTG page 5 and Board Layout Reference page 21 on the NetbellNTG User Manual)

ACTIVATING THE DIGITAL INPUT

Note: The following guide will assume you are using Digital input 1 and the tone EVACUATE.
Navigate to the Services dropdown menu and select Inputs. The top 4 items are your digital inputs. They are marked DIN 1 –DIN 4. Click on the pencil icon under DIN 1 and enter the following settings.
Name: You can set a 15-character name for this input. This name goes in the bar at the top of the display.
USE: Sets this input to active. When this box is checked, it will turn the input number indicator to green.
Type: Select State, this is for knowing if an input is on or off.
Display: This selections lets you change the display type used.
Relay L/T: E nter 1L, which means this input is linked to Relay 1.
Command Z/N/I: Enter I, which means Invert Input.
Click SAVE button.

LINORTEK NETBELL-NTG-W External Trigger-1

SETTING TASK FOR DIGITAL INPUT

Now that your external trigger is wired to your NetbellNTG and your digital input is configured, you will need to set up a task.

  1. Navigate to the Tasks page
  2. Click the Edit icon on the first available task
  3. Name the task if desired
  4. Check the Use box
  5. Set Device A to Digital
  6. Set Data A to 1S=1 (1 represents the number of the digital input, S signifies to your device to refer to input state, the last 1 signifies the state is on)
  7. Set Device C to Send UART
  8. Set Data C to PEVACUATEOGG (to play sound file EVACUATE in this sample)
  9. Set Action to ON
  10. Click Save

LINORTEK NETBELL-NTG-W External Trigger-2

If you are using a trigger such as a door contact switch, set Data A in the example above to 1S=0 to play the tone when the contact is broken.
For instructional videos, FAQ’s and contact information for our technical support team, please visit: https://www.linortek.com/technicalsupport
For full instructions on the device, please see the NetbellNTG
User Manual available at: https://www.linortek.com/downloads/documentations/

Information subject to change without notice.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LINORTEK User Manuals

Related Manuals