LINORTEK Koda 100 Web Controller User Guide

May 15, 2024
LINORTEK

LINORTEK-logo

LINORTEK Koda 100 Web Controller

LINORTEK-Koda-100-Web-Controller-product

Product Information

Specifications:

  • Product Name: Linortek Web Controller
  • Model: Koda 100 / Koda 200
  • Connectivity: Ethernet
  • External Sensor Compatibility: Mini USB connector for temperature & humidity sensor

Product Usage Instructions

Product Checklist:
Upon arrival, ensure the kit contains all necessary components:

  • Linortek Web Controller
  • All required parts and software

Installation:

  1. Visit http://linortek.com/downloads/Documentation for the product manual.

External Temperature & Humidity Sensor Setup:

  1. Login to your Koda device and go to the Settings page.
  2. Check the “Use AM2302” box to enable the external sensor.
  3. Check the “Active Landing Page” if you want to view temperature and humidity without logging in.
  4. Save settings and proceed to the Set Analog Input page.
  5. Edit AIN 2 to set analog input for humidity monitoring.
  6. Set Digital Inputs 1 and 2 according to your application needs.
  7. Click the “PAUSE” button to log out and view the landing page.

For more information:

FAQ:

  • Q: Can this product control line voltage devices?
    A: No, this product is not designed to switch line voltage devices. For such devices, an intermediary device like a relay must be installed.

Thank you for purchasing the Linortek web controller. All of our web controllers come complete with all parts and software necessary for installation, operation and the ability to control the devices attached to them. Upon arrival, please inspect the contents of the box to ensure that your kit is complete and contains all necessary components.

PRODUCT CHECKLIST

Each product kit box contains the following:

  • One Web Controller (SERVER)
  • One CAT5 (or better) Patch Cord
  • One Power Supply
  • Quick Start Guide

For complete product documentation, current software, web pages and various utilities, visit https://www.linortek.com/downloads/. The product manual, as well as software updates, are available for download.

INSTALLATION

Linortek SERVER is simple to install and operate. If you require further direction, please download the product manual at http://linortek.com/downloads/Documentation.

  • Connect your device(s) with the SERVER (For wiring instructions, please refer to the Manual.)
  • Connect the SERVER to a router or computer.
  • Connect the power supply.
  • Download the Discover program from our website to identify the SERVER IP address (i.e. 192.168.nnn. in).

SUPPORTING PROGRAMMING – DISCOVERER

Discover.jar – Discover.jar is a program that will automatically locate your SERVER. When a SERVER unit is first installed on your network, it automatically obtains a web address from your router via DHCP if your router is set up to assign one. If your router is not set this way, it is suggested that you turn that feature on so you can operate the SERVER and assign it the IP address of your choosing. (The Discover is a Java program. Java runtime needs to be loaded to use this feature.Java can be found here: http://java.com/en/download/index.jsp). To download the Discover program, please go to: https://www.linortek.com/downloads/support-programming/.

Use of Chrome & Firefox browsers is recommended. If you prefer to use the Internet Explorer browser, please note that when you download the Discover program, Internet Explore saves this program as a Zip file by default. To use the Discoverer, you need to select Save as and rename the file as “Linortek Discoverer.jar” when you download it with the Internet Explorer browser.

Once Discoverer locates your device, it will display:

  1. IP Address
  2. Host Name
  3. MAC Address
  4. Other Info:
    • Blue LED (if on)
    • Product Name
    • Server Software Revision

LINORTEK-Koda-100-Web-Controller-fig- \(1\)

Click the device you want to use shown on the Discover program, and launch the SERVER web pages in the browser. Click the Login button on the homepage. The default username/password is admin/admin. You may change these as you desire or disable this feature in the settings menu.

Note:
If you can’t make the Discover program work, you can ping the SERVER to get its IP address on your network. Here is how:

  1. To bring up the run dialogue, press the Windows key.
  2. Type cmd and press Enter or open the Start menu type in cmd on the search bar, and select cmd program.
  3. Type ping server and press Enter.

If the ping is successful, you should receive replies from the address that you are trying to ping. Open your browser and type in the IP address displayed on the ping window.

If you still have trouble finding the IP address, you can connect the SERVER directly to your computer Ethernet port, turn off the WiFi, open the browser, type in SERVER’s default IP address 169.254.1.1 to access the webpage to setup your device.

EXTERNAL TEMPERATURE & HUMIDITY SENSOR
In our recent hardware updates, we added a mini USB connector to our Koda 100 and Koda 200 boards to make it easier to use an external temperature & humidity sensor. Once you connect the external temperature & humidity sensor, please follow these setting instructions:

  1. Login to your Koda device, go to Settings – Settings page, check the Use AM2302 box to enable the external sensor, and check Active Landing Page if you want to check the temperature and humidity value without the need to log into the device page, then click Save button. After the Settings Saved Successfully message appears on top of the Settings page, you can now go to the Set Analog Input page to set up the Temp. & Humd. sensor.LINORTEK-Koda-100-Web-Controller-fig- \(2\)
  2. The external sensor is an analog input, it can be used to monitor both temperature and humidity. To set the analog input, go to the Service – In/Out page, and click the AIN 1 edit icon to set analog input for temperature monitoring. On the Set Analog Input page, you can give a name for this input, since this input is for temperature monitoring only, you can simply name it Temperature, this name will display on the landing page, then check the USE box, and select Ext. Temp from the drop-down menu of the Input line, and set your preferred display value, then click Save. Please note: The Landing Page will only display as a meter.
  3. Click the AIN 2 edit icon to set analog input for humidity monitoring. On the Set Analog Input page, give it a name as Humidity since this input is for Humidity monitoring only, check the USE box, select R. Humidity from the drop-down menu of the Input line, and set your preferred display value, then click Save. The landing page will only display as a meter.
  4. Set your Digital Input 1 and 2 according to your application. The Input 1 and 2 name and status will be displayed on the landing page. For example, if you use Input 1 to monitor the Door and Input 2 for Power monitoring, you can simply label your digital inputs like this:LINORTEK-Koda-100-Web-Controller-fig- \(3\)
  5. After setting up the Analog Inputs and Digital Inputs, click the PAUSE button on the upright corner of the page, you will be logged out and reach your landing page:LINORTEK-Koda-100-Web-Controller-fig- \(4\)

For more information on how to set up and use your SERVER, please download the product manual on our website Documentation Download page: https://www.linortek.com/downloads/documentations/. Video Tutorials are also available here: www.linortek.com/downloads/.

LIMITATION OF LIABILITY

IN NO EVENT WILL LINOR TECHNOLOGY BE LIABLE, WHETHER IN CONTRACT, TORT, OR OTHERWISE, FOR ANY INCIDENTAL, SPECIAL, INDIRECT, CONSEQUENTIAL OR PUNITIVE DAMAGES, INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR ANY LOSS OF USE, LOSS OF TIME, INCONVENIENCE, COMMERCIAL LOSS, OR LOST PROFITS, SAVINGS, OR REVENUES TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY LAW.

FURTHER NOTICE FOR LIMITATION OF USE
Unless specifically stated, this product is NOT designed to switch line voltage devices. This limitation includes all of FARGO AND KODA products. To control devices that operate at line voltages the user MUST install an intermediary device such as a relay. When choosing devices to control, it is best to select low-voltage controls such as a 24VAC solenoid for water flow control.

When wiring a line voltage device you MUST either be a qualified electrician or use the services of a qualified electrician. Additionally, local codes must be followed including but not limited to wire gauge size and suitable housing.
Linortek cannot assume any responsibility for harm to the user or third parties for improperly using our Fargo product. This liability remains with the user. Linortek cannot assume any responsibility for damage to the device for improperly using our SERVER product.

RELAY VOLTAGE SPECIFICATIONS

Please use caution when connecting devices. All SERVERs except Koda 100, Netbell-2 and Network Hour Meter are NOT designed to connect to any voltage greater than 48V. If you want the unit to control Line Voltage products and devices, refer to the Diagram below. Utilizing this arrangement should allow you to virtually control anything. You must use licensed electricians and comply with electrical codes that apply to your location. These codes exist for your safety, as well as the safety of others. Linortek cannot assume any responsibility for any harm or damage caused by not following specified instructions for installation and product usage.

Typical Low Voltage Wiring

LINORTEK-Koda-100-Web-Controller-fig- \(5\)

  • Winston Salem, NC 27127
  • www.linortek.com
  • Information is subject to change without notice.
  • 0150800009A
  • 0518 R001V005

Printed in U.S.A.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>