NICOR HML1 LED High-Performance High Bay Instruction Manual

June 2, 2024
NICOR

NICOR - logo HML1 LED High-Performance High Bay
Instruction Manual

HML1 LED High-Performance High Bay

Product Description
NICOR introduces the newest high bay product line: the patent pending, ultra- efficient, high performance HML high bay. With only a 10×14″ footprint (on lower wattages), its compact design offers an impressive light output with simple, single-person installation. The DLC 5.1 Premium certified fixture offers a variety of wattage, sensor, and aisle distribution options. It’s durable single-piece cast aluminum design is perfect for rugged applications like warehouses, gymnasiums, and other industrial or commercial spaces.
Construction

  • Fully cast aluminum body with integrated cooling features
  • Top mounted wireway cover for easy wire access
  • Polyester powder coat finish

Optical System

  • Standard diffused lens
  • Optional aisle lens (40° x 100°) available
  • Optional wide lens (105° x 105°) available
  • CCTs of 4000K and 5000K with >80 CRI

Electrical

  • Offers multiple power levels: 100W, 130W, 150W, 210W, 300W and 450W
  • Operating temperature rating of -4ºF to 131ºF (-20ºC to 55ºC)
  • Input voltage of 120-277V, 277-480V input option available
  • Dimming: 0-10V standard

Controls

  • Pre-installed sensor socket models available
  • Field installable multifunction MW or PIR sensor available (on sensor socket models)
  • Standard full-range dimming with compatible 0-10VDC dimmers
  • 12VDC output provides power to off-board sensors or controls

Mounting and Installation

  • V-hook and chain mounting system included
  • Wireguard option available for increased fixture protection
  • Pendant mount and surface mount kits available
  • For installations where power surge may be possible, NICOR recommends installing
    additional surge protection at the fixture or electrical distribution panel

Listings

  • cULus1598 Listed for damp locations
  • ASHRAE 90.1 compliance when specified with sensor option
  • RoHS Compliant
  • Meets FCC Part 15, Subpart B, Class A standards for conducted and radiated emissions
  • TM-21 Reported L70(10k) life >60,000 hours
  • LM-79, LM-80 testing performed in accordance with IESNA standards

Warranty

  • 5-year limited system warranty standard
  • Warranty does not cover product failure due to an overvoltage event (power surge)

Project
Catalog
Type
DateNICOR HML1 LED High-Performance High Bay

Ordering Information

Series| Version| 100 (14000 lm)| Input Voltage| CCT| Distribution| Sensor Socket| Emergency| Wiring Options
---|---|---|---|---|---|---|---|---
HML| 1| 130 (18000 lm)| U (120-277V)| 40 (4000K)| A (general – 90°x90°)| Blank (No)| Blank (No)| Blank (No)
| | 150 (20000 lm)| H (277-480V)| 50 (5000K)| B (wide – 105°x105°)| S (socket)| E08 (8W)²| C (Cord – 3-ire, 6ft)6
| | 210 (29000 lm)| | | C (aisle – 40°x100°)| | E18 (18W)³| C4 (Cord -4-wire, 6ft)7
| | 300 (42000 lm)| | | | | E25 (25W)4| F (Flex Conduit – ft)8
| | 450 (66000 lm)| | | | | E40 (40W)5|

Specifications and dimensions subject to change without notice.

  1. Only on 150W and higher models

  2.  8W is for 100W version only

  3. 18W for 100-150W versions only

  4. 25W is for 210W version only

  5. 40W is for 300-450W versions only
    Note: End user is reponsible for proper selection of battery pack to meet NFPA requirements

  6. C3 Cord is 18/3 wire, 6’ long, black. Other lengths available upon request

  7. C4 cord is 18/4 wire, 6’ long, black, for use with Emergency enabled fixtures. Other lengths available upon request

  8. Flexible metal conduit is 6’ long, 18/3 wire configuration. Other lengths available upon request

Motion Sensors

Passive Infrared Motion Sensor H12VSENSORPIR
Microwave Motion Sensor H12VSENSORMW
Remote Control for Sensors H12VREMOTE

Motion sensors for use on socket enabled (“S”) fixtures only
Wireguard Accessories

Wireguard for HML1 100-150W HML1WGNS
Wireguard for HML1 210-300W HML1WGND
Wireguard for HML1 450W HML1WGNT

Mounting Accessory Kits

Aircraft Cable Kit (10ft) ACMK110
Pendant Kit for 100-450W HML1100-150PEND
Surface Mount Kit for 100-450W HML1100-150SURFACE

Pendant and surface mount kits compatible to all HML models, 100W-450W
Emergency Battery Accessories

8W Battery Pack (120-347V) HML1EM08WRVWH
18W Battery Pack (120-347V) HML1EM18WRVWH
25W Battery Pack (120-347V) HML1EM25WRVWH
40W Battery Pack (120-347V) HML1EM40WRVWH
  • For installation in the field by the end user
  • 8W is for 100W version only
  • 18W for 100-150W versions only
  • 25W is for 210W version only
  • 40W is for 300-450W versions only
  • End user is reponsible for proper selection of battery pack to meet NFPA requirements

Plug Accessories

15A 125V Straight Bladed Plug 515P
15A 125V Twist Lock Plug L515P
15A 250V Twist Lock Plug L615P
15A 277V Twist Lock Plug L715P
20A 277V Twist Lock Plug L720P
20A 347V Twist Lock Plug L2320P
20A 480V Twist Lock Plug L820P

Plugs not available for C4 (4-wire cord) or F (flex conduit) options

NICOR HML1 LED High-Performance High Bay - figPerformance Data

Standard Distribution

Model Number Lumens Watts Lumens/Watt

 HML1100U40A
HML1100U50A| 14200
14284| 101| 141
141
HML1130U40A
HML1130U50A| 18138
18228| 129| 141
141
HML1150U40A
HML1150U50A| 20574
20675| 147| 140
141
HML1210U40A
HML1210U50A| 29258
29412| 209| 140
141
HML1300U40A
HML1300U50A| 42055
42266| 305| 137
138
HML1450U40A
HML1450U50A| 66516
66850| 459| 144
145

Wide Distribution

Model Number Lumens Watts Lumens/Watt

 HML1100U40B
HML1100U50B|  14200
14284| 101| 141
141
HML1130U40B
HML1130U50B| 18138
18228| 129| 141
141
HML1150U40B
HML1150U50B| 20574
20675| 147| 140
141
HML1210U40B
HML1210U50B| 29258
29412| 209| 140
141
HML1300U40B
HML1300U50B| 42055
42266| 305| 137
138
HML1450U40B
HML1450U50B| 66516
66850| 459| 144
145

Aisle Distribution

Model Number Lumens Watts Lumens/Watt

 HML1150U40C
HML1150U50C| 19134
19228| 147| 130
131
HML1210U40C
HML1210U50C| 27204
27338| 209| 130
131
HML1300U40C
HML1300U50C| 39251
39307| 305| 131
131
HML1450U40C
HML1450U50C| 61860
62171| 459| 134
135

Emergency Operation Lumens

Model Number 8W 18W 25W 40W

HML1100U40A
HML1100U50A|  1128
1128|  2538
2538|  X
X| X
X
HML1130U40A
HML1130U50A| X
X| 2538
2538| X
X| X
X
HML1150U40A
HML1150U50A| X
X| 2520
2538| X
X| X
X
HML1210U40A
HML1210U50A| X
X| X
X| 3500
3525| X
X
HML1300U40A
HML1300U50A| X
X| X
X| X
X| 5480
5520
HML1450U40A
HML1450U50A| X
X| X
X| X
X| 5760
5800

Emergency Operation Lumens

Model Number 8W 18W 25W 40W
HML1100U40B 1128 2538 X X
HML1100U50B 1128 2538 X X
HML1130U40B X 2538 X X
HML1130U50B X 2538 X X
HML1150U40B X 2520 X X
HML1150U50B X 2538 X X
HML1210U40B X X 3500 X
HML1210U50B X X 3525 X
HML1300U40B X X X 5480
HML1300U50B X X X 5520
HML1450U40B X X X 5760
HML1450U50B X X X 5800

Emergency Operation Lumens

Model Number 18W 25W 40W
HML1150U40C 2340 X X
HML1150U50C 2358 X X
HML1210U40C X 3250 X
HML1210U50C X 3275 X
HML1300U40C X X 5240
HML1300U50C X X 5240
HML1450U40C X X 5360
HML1450U50C X X 5400

Fixture tested per LM-79-08.  Photometric data is of the performance of a representative fixture.  Results may vary in the field.
Photometric Data

100W 5000K

Input Voltage (VAC)| 120-277| 277-480
System Level Power (W)| 101.0| 98
Delivered Lumens (Lm)| 14284| 13858
System Efficacy (Lm/W)| 141.4| 141.4
Correlated Color Temp (K)| 3553
Color Rendering Index (CRI)| 86
Beam Angle (0)| 89.1
Beam Angle (90)| 90.6
Spacing Criteria (0)| 1.26
Spacing Criteria (90)| 1.26
CCT Data Multiplier

4000K| 0.995

NICOR HML1 LED High-Performance High Bay - Featured
Image

Cone of Light Tabulation

Mounted height (Feet) Footcandles Beam Center Diameter (Feet)
15 30 29.5
17 23.4 33.5
20 16.9 39.4
23 12.8 45.3

130W 5000K

Input Voltage (VAC)| 120-277| 277-480
System Level Power (W)| 129| 125
Delivered Lumens (Lm)| 18228| 17573
System Efficacy (Lm/W)| 141.3| 140.6
Correlated Color Temp (K)| 3560
Color Rendering Index (CRI)| 86
Beam Angle (0)| 89.0
Beam Angle (90)| 90.6
Spacing Criteria (0)| 1.26
Spacing Criteria (90)| 1.26
CCT Data Multiplier

4000K| 0.995

NICOR HML1 LED High-Performance High Bay - fig 2
Cone of Light Tabulation

Mounted height (Feet) Footcandles Beam Center Diameter (Feet)
15 38.4 29.5
17 30 33.5
20 21.7 39.4
23 16.4 45.3
25 13.8 49.2

150W 5000K

Input Voltage (VAC)| 120-277| 277-480
System Level Power (W)| 147| 147
Delivered Lumens (Lm)| 20675| 20664
System Efficacy (Lm/W)| 140.6| 140.6
Correlated Color Temp (K)| 3532
Color Rendering Index (CRI)| 86
Beam Angle (0)| 88.9
Beam Angle (90)| 90.6
Spacing Criteria (0)| 1.26
Spacing Criteria (90)| 1.26
CCT Data Multiplier

4000K| 0.995

NICOR HML1 LED High-Performance High Bay - fig 3Fixture tested per LM-79-08. Photometric data is of the performance of a representative fixture. Results may vary in the field.
Cone of Light Tabulation

Mounted height (Feet) Footcandles Beam Center Diameter (Feet)
15 43.7 29.5
17 34.1 33.5
20 24.6 39.4
23 18.6 45.3
25 15.7 49.2
28 12.5 55.1

210W 5000K

Input Voltage (VAC)| 120-277| 277-480
System Level Power (W)| 209
Delivered Lumens (Lm)| 29412| 29396
System Efficacy (Lm/W)| 141| 141
Correlated Color Temp (K)| 5000
Color Rendering Index (CRI)| 85
Beam Angle (0)| 88.7
Beam Angle (90)| 90.5
Spacing Criteria (0)| 1.28
Spacing Criteria (90)| 1.26
CCT Data Multiplier

4000K| 0.995

Cone of Light Tabulation

Mounted height(Feet) Footcandles Beam Center Diameter (Feet)
23 41.4 45.3
25 35 49.2
28 27.8 55.1
30 24.2 59.1
32 21.1 63

300W 5000K

Input Voltage (VAC)| 120-277| 277-480
System Level Power (W)| 305
Delivered Lumens (Lm)| 42266| 42243
System Efficacy (Lm/W)| 139| 139
Correlated Color Temp (K)| 5000
Color Rendering Index (CRI)| 86
Beam Angle (0)| 88.9
Beam Angle (90)| 90.6
Spacing Criteria (0)| 1.28
Spacing Criteria (90)| 1.26
CCT Data Multiplier

4000K| 0.995

NICOR HML1 LED High-Performance High Bay - fig 5 Cone of Light Tabulation

Mounted height (Feet) Footcandles Beam Center Diameter (Feet)
23 60.1 45.3
25 50.8 49.2
28 40.4 55.1
30 35.2 59.1
32 30.7 63

450W 5000K

Input Voltage (VAC)| 120-277| 277-480
System Level Power (W)| 459
Delivered Lumens (Lm)| 66850| 66783
System Efficacy (Lm/W)| 145| 145
Correlated Color Temp (K)| 5000
Color Rendering Index (CRI)| 86
Beam Angle (0)| 88.9
Beam Angle (90)| 90.6
Spacing Criteria (0)| 1.28
Spacing Criteria (90)| 1.26
CCT Data Multiplier

4000K| 0.995

NICOR HML1 LED High-Performance High Bay - fig 6 Cone of Light Tabulation

Mounted height (Feet) Footcandles Beam Center Diameter (Feet)
23 60.1 45.3
25 50.8 49.2
28 40.4 55.1
30 35.2 59.1
32 30.7 63

Fixture tested per LM-79-08. Photometric data is of the performance of a representative fixture. Results may vary in the field.
Dimmers and Sensors
Recommended Dimmers**
Lutron NTSTV
Lutron DVSTV
Cooper SF10P
Legrand RH4FBL3PW
Not a complete list. Check compatibility before installation.
12VDC Output
On “S” (sensor socket) models, there is an additional 12VDC output on the driver. This output can be used to provide power to external low voltage sensors or controls. Do not use the 12VDC output if a sensor is installed in the socket.
NICOR Lighting Controls (NLC)
Any “S” (sensor socket) model can be converted to use with NICOR LIghting Controls (NLC) by installing the NLC sensor. For more information please see the information and spec sheets for the NLC system.
Microwave Motion Sensor (H12VSENSORMW)
** See the individual spec sheet for further information

  • Field installed 12VDC sensor
  • Microwave motion detector with built in daylight sensor
  • Remote control programmable
  • Highly configurable:
  • Detection area
  • Hold time
  • Dimming level
  • Stand-by period
  • Stand-by dimming
  • Daylight harvesting threshold
  • Max mounting height: 40ft (12m)
  • IP65 Rated

NICOR HML1 LED High-Performance High Bay - fig 7 Passive Infrared (PIR) Motion Sensor
See the individual spec sheet for further information

  • Field installed 12VDC sensor
  • Microwave motion detector with built in daylight sensor
  • Remote control programmable
  • Highly configurable:
  • Detection area
  • Hold time
  • Dimming level
  • Stand-by period
  • Stand-by dimming
  • Daylight harvesting threshold
  • Max mounting height: 40ft (12m)
  • IP65 Rated

NICOR HML1 LED High-Performance High Bay - fig 8 Remote Control for Sensors (H12VREMOTE)
See the individual spec sheet for further information

  • Allows programming of MW or PIR sensors
  • Allows adjustment of:
  • Brightness
  • Hold time
  • Stand-by dim level
  • Stand-by time
  • Sensor sensitivity
  • Daylight harvesting threshold

DimensionsNICOR HML1 LED High-Performance High Bay - fig
10

Product Measurements

 | 100W-150W| 210W, 300W| 450W
Length:| 14.1 in. (360mm)| 28.3 in (720mm)| 42.5 in. (1080mm)
Width:| 10.1 in. (260mm)
Height:| 1.9 in. (49mm)

NICOR HML1 LED High-Performance High Bay - fig 11

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

NICOR - logoNICOR, Inc. 2200 Midtown Place NE, Albuquerque,
NM 87107 P: 800.821.6283 F: 800.892.8393
www.nicorlighting.com
June 30, 2022 1:27 PM rev 2.0

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

NICOR User Manuals

Related Manuals