Herschel COLORADO 2500R Watts Ceiling Wall Mounted Infrared Heaters Instruction Manual

June 3, 2024
HERSCHEL

Herschel - logo COLORADO 2500R Watts Ceiling Wall Mounted Infrared Heaters
Instruction ManualHerschel COLORADO 2500R Watts Ceiling Wall Mounted
Infrared Heaters INSTALLATION & OPERATING INSTRUCTIONS

****Original instructions covering COLORADO 2500R produced 072021 onwards. SAA Certificate SAA-211697-EA

IMPORTANT SAFETY PRECAUTIONS

READ THESE INSTRUCTIONS CAREFULLY AND RETAIN FOR FUTURE REFERENCE.
Failure to observe these instructions will invalidate the warranty.
This unit may be a source of possible shock.
Disassemble only to replace lamp. No user-serviceable parts inside.
Source of possible ignition.

WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:

  1. Remove the unit from its packaging and check it to ensure it is in good condition before installing and operating.

  2. Send the packaging to be recycled. DO NOT let children play with plastic bags or other parts of the packaging.

  3. CAUTION: Risk of Electric shock
    a. This appliance must be disconnected from its power source during installation or service activities and when replacing.
    b. DO NOT use this heater in the immediate surroundings of a bath, shower or swimming pool or hot tub where it could fall into a container full of water.
    c. Switches and other controls must not be within reach of a person in a bath, pool, hot tub or shower.
    d. DO NOT touch this heater or its controls with wet hands.
    e. DO NOT allow power cables to become immersed in water or other liquid.
    f. DO NOT open or try to repair the heater yourself. Servicing should be performed by qualified personnel only.

  4. In order to avoid overheating and potential fire hazard, DO NOT cover the heater under any circumstances. If the heater should become accidentally covered during  operation, turn it off immediately and clear out any foreign objects that have covered the heater or become lodged in the grill.

  5. The unit must be installed with a minimum clearance of 1800mm (71”) to the floor and 300mm (12”) clearance at the top and sides of the heater.

  6. DO NOT touch the heater when in use. Parts of the heater may exceed 200°C / 392°F during operation. Contact with the heater during operation may cause severe  burns. Do not touch the heater during or for 10 minutes after operation.

  7. DO NOT use the heater if the power cord is damaged. This must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a  hazard.

  8. DO NOT use the heater to ignite materials. DO NOT operate in locations containing gasoline, flammable liquids or other volatile substances.

  9. DO NOT install the heater pointing directly downwards.

  10. DO NOT install this heater near, or pointing towards flammable objects within 1 metre or where curtains, towels or other flammable items can be blown onto the  heater.

  11. This heater must only be used for the heating of people outdoors or indoors in an unenclosed space. The COLORADO is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, regardless of whether they have been given instruction or are under supervision.  Children should be kept away and should not be left unsupervised around the unit.

  12. All operators shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given  supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not plug in, switch on or regulate the  appliance or perform user maintenance including cleaning.

  13. DO NOT leave the heater operating unattended.

  14. NEVER place hands under the heating element during operation.

  15. IMPORTANT: Ensure supply voltage does not exceed 245 Volts.

SAVE THESE INSTRUCTIONS.

WATER INGRESS PROTECTION:
Herschel COLORADO is rated to a standard IP55. Suitable for outdoor use.
Installation in potentially wet or humid rooms such as bathrooms must be carried out by a suitably qualified installer and comply with local electrical safety requirements.
If in doubt, do not install. Herschel Infrared Ltd shall not be liable for any loss, damage or injury caused or resulting from inadequate fitting or incorrect placement of heaters close to water sources.

ELECTRICAL INFORMATION:
The Herschel COLORADO may be plugged in to a waterproof socket. Any extension lead used must have sufficient capacity to carry the current required by the heater as  show in in Table 1. All plugs, sockets and switches intended for use outdoors must have an appropriate water ingress protection.
Alternatively the plug can be removed and the unit connected to fixed mains wiring. Fixed wiring installations must only be carried out by competent persons or a qualified  electrician according to national regulations and the unit must be earthed. The electrical supply to the unit should be provided by connecting to a current protection device  suitable for the electrical rating of the unit in accordance with Table 1 and providing disconnection in both poles. All fixed wiring must have sufficient capacity to carry the  current required by the heater.
Always disconnect the heater from the power when not in use.

Table 1. Electrical Specification

Model| Rated Power| Voltage| Current| Frequency| Fuse (Minimum)
---|---|---|---|---|---
COLORADO 2500R| 2500W| 220-240V| 10.9A| 50/60Hz| 13A

The mounting position of the unit must ensure that any mechanical damage to the flexible cable is unlikely.
Any exposed flexible cable is to hang down (not tied UP) and must have adequate clearance from the heater to prevent scorching or damaging the cable. Colour coding used  in the supplied mains cable: BROWN wire is to be connected to LIVE (‘L’), the BLUE wire to NEUTRAL (‘N’) and the GREEN/YELLOW wire to EARTH (‘E’).

MOUNTING POSITION:

The recommended installation height of the COLORADO is 1.8m – 2.4m (71” – 95”) from the floor. The lower the heater is positioned, the more intense the heat.
Under no circumstances is the COLORADO to be installed at less than 1.8m (71”) from the floor.
Consideration should be given to any temporary or occasional additions such as stages or platforms and adjusted accordingly. For outdoor use, or other areas with air  movement/wind the directional Infrared spread may reduce by 1/3 to 1/2. In all locations, ensure hot parts are not touched accidentally.
Wall mount swivel brackets are provided with the heater which has been specifically designed to allow this product to be fitted to a wall with adequate clearances at the back  of the unit. Do not mount the heater with any other bracket except those provided.
The sides and ends of the heater must always be at least 300mm (12”) away from the nearest wall, ceiling or other structure.

INSTALLATION

Diagram 1: Bracket AssemblyHerschel COLORADO 2500R Watts Ceiling Wall
Mounted Infrared Heaters - Figure 1

Mounting Hardware Includes:

  • 4 x bracket pieces – fit together to form 2 brackets with a central pivot. The protruding blade on each bracket fits over the circular end of the opposing bracket to ensure  the correct pivot angle.
  • 4 x M6x60 masonry expansion bolts (for fitting brackets onto wall).
  • 2 x wing nuts to fit brackets onto the rear of the heater.
  • 2 x small bolts and lock nuts (to form the pivot on the brackets).

Using the brackets as a template, mark and drill 4 x 8mm holes in the wall. Insert the plugs into the wall and fit the brackets, washers, spring washers and nuts over the  exposed threaded ends.
Tightening the nuts will force the plug end to expand in the wall and form a secure mounting for the heater.
Fit the opposite bracket to the back of the heater before then inserting and tightening the bolt and nut for each hinge.

Diagram 2: Correct Wall / Ceiling PositionHerschel COLORADO 2500R Watts
Ceiling Wall Mounted Infrared Heaters - Figure 2

Diagram 3: Installation using a stand
The Colorado may be installed on an adjustable stand (Model M-Stand, available separately). Installation is easy following the diagrams below.Herschel
COLORADO 2500R Watts Ceiling Wall Mounted Infrared Heaters - Figure
3

CAUTION:

  • Ensure mains power is OFF before commencing installation.
  • The supplied mains cable must not contact the top surface of the heater during operation.
  • Heater must not be located immediately below a socket outlet. Electrical connections must be made outside of the footprint of the unit to avoid heat build-up. If the  heater is to be mounted on an incline (e.g. sloping roof), ensure the electrical connection is located below the lowest end of the heater.
  • Joists, beams and rafters shall not be cut or notched to install the appliance.
  • This heater is not intended for ceiling-recessed installation. Do not install pointing directly downwards.
  • The identification mark and model reference should be visible after installation.
  • The COLORADO must not be attached facing or close to any combustible material (eg, wood or PVC cladding, fascia or soffit) or other materials that could blow onto the heater.
  • The fixed wiring insulation coming into contact with parts with a temperature rise of greater than 50°C must be protected, for example, by sleeving having an  appropriate temperature rating.
  • Exercise caution when siting the heater stand that the heater cannot accidentally be touched, knockedover or that the wire causes a tripping hazard.
  • Never place the tend and heater next to a swimming pool, pond or other water source.

INITIAL USE:

The power switch on the side of the COLORADO has 3 positions:

  • Position O (Off)
  • Position I (Remote bypass)
  • Position II (Remote control).

CAUTION:
The power switch may become unintentionally switched to position I (Remote Bypass) during unpacking and installation. To avoid any possibility of burns, ensure the power  switch is in the OFF position (marked O on the switch) before switching on mains power.
Position I. To bypass the remote control, turn the switch on the heater to position I. When the switch is in this position the heater will turn on or off depending on whether it has power to it. The remote control unit will not control the heater when the switch is in position I. Use this where you wish to hard wire the heater to a switching device  such as a push button timer or thermostat.
Position II. To use the heater with the remote control, ensure the switch of the heater is switched to position II.
Insert 2 x AAA Alkaline batteries into the remote control.
The remote control operates the heater remotely on or off with adjustable heat level and timer described below. All Herschel remote controls have the same frequency, so it is  possible to control several heaters with just one remote.
There may be odor or vapor from the heater on initial use or if it has not been used for an extended period. This is normal.

OPERATION BY REMOTE CONTROLLER

Remote Control Function

Button| Function (Heater On)| Function (Heater Off)| LED Display on Heater
1| Turns heater on or off| |
2| Increase Heat Level or Timer hours| Turns heater on to Level 1 (minimum)| L1
3| Decrease Heat Level or Timer Hours| Turns heater on to Level 4 (Maximum)| L4
4| Enable Timer adjustment| | 00 – 24
5| Enable Heat Level adjustment| | L [n]

All Herschel remote controls have the same frequency, so it is possible to control several heaters with just one remote.
Safety & Energy-saving protection:

  • If a heater with remote control is left switched on continuously for a week (168 hours), the heater will automatically switch itself off and must be restarted.
  • Heaters with remote controllers are equipped with an overheat switch which will cut power to the heater if it senses an overheat in the electronics. Please let the heater  cool down for 15 minutes before attempting to restart.

USER MAINTENANCE

The heater may be wiped-down with a soft damp cloth. Do not use abrasive detergents to clean the unit. In marine environments, the unit may be gently sprayed clean with  clean water with the POWER TURNED OFF and completely cool. After cleaning, it is advisable to warm the heater for 10 – 20 minutes to dry the unit and prevent staining.
The lamp used in the Herschel Colorado is Ultra long life (up to 10,000 hours). Changing the lamp should only be carried out by suitably qualified personnel using the  instructions available on Herschel’s website.

TROUBLESHOOTING:

E1 Error on Display:| Control unit overheat. Check installation clearances. Let heater cool for 15 minutes and restart heater.
---|---
L1,2,3,4 shows in display, but no heat:| Lamp is damaged. Arrange for replacement lamp with your Herschel Dealer.

TECHNICAL INFORMATION:

Rated Power: 2500W at 220-240V
Heating Element: Ultra long life Carbon heating lamp (up to 10,000 hours)
Reflector: Mirror Aluminum (98% reflection preventing rearward heat loss)
Dimensions: 879 x 195.3 x 84.7 mm
Remote control: 4 power levels (25% power increments) & 0-24 hour timer
Warm-up time: (24 x 1 hour increments)
Useful wavelength range: 5-10 seconds
Weight: 2 – 5μm
Warranty: 3kg
Protection: 2 Years (excludes lamp & remote control) IP55

WARRANTY

Register your product here: https://www.herschel-infrared.co.uk/customer- service/warranty-registration/
The Herschel COLORADO is guaranteed against failure due to faulty materials or workmanship for two years from date of purchase excluding the lamp and remote control  unit. The warranty will be invalidated if the unit is opened, tampered with or mis-used. In the unlikely event of failure of the unit within this time, the unit must be returned to  the supplier for repair or replacement. The guarantee is invalid if the correct installation instructions as given in this leaflet have not been adhered to. Refer to Herschel  Infrared Ltd’s warranty policy for full details. See https://www.herschel- infrared.co.uk.

Note your serial number here:|
---|---

ELECTRICAL EQUIPMENT:
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.

IMPORTANT NOTICE TO PURCHASER:
Before utilizing the product, you should determine the suitability of the product for its intended use.
HERSCHEL INFRARED LTD expressly disclaims the implied warranties and conditions of merchantability and fitness for a particular purpose. In no case shall  HERSCHEL INFRARED LTD be liable under any legal theory, including but not limited to contract or strict liability, for any direct, indirect special, incidental or consequential damages resulting from product use.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

HERSCHEL User Manuals