Product description
- • Scans all channels, amplifies the weak signals while keeping the strong channels
• All output channels have an equal and stable output power
• Treats even the most difficult situations with adjacent channels
• Channels with the same frequency can be amplified in and re-located to the LTE band (switchable)
• Fully automatic channel scan and process function upon double power start- up.
• Fully automatic recognition of the applied country channel plan
• SAW filters for LTE (4G or 5G) protection on all inputs
• Outdoor weatherproof mast-head housing
• DC Power over coax
• All ports ESD protected
Package contents
- • 1 Smart Amp (ref. 7472L1 – 7472L2)
• Optional: Power Supply 12V (ref. 2437)
TECHNICAL SPECIFICATIONS
7472L1 | 7472L2 | ||
---|---|---|---|
Inputs | – | 2 | 2 |
Outputs | – | 4G (> CH60) | 5G (> CH48) |
Frequency range | – | VHF BIII + UHF |
Automatic channel plan selection
LTE band rejection| dB| >40
Output| –| 1
Output Power| dBµV| 90
Frequency Range| MHz| 174 – 862
LTE band Re-use| –| L1 = CH61-69 (790MHz- 862MHz)
Switch ON-OFF
| L2 = CH49-69 (694MHz-862MHz)
Switch ON-OFF
Adjacent channel isolation| dB| >35
Input sensitivity| dBµV| 40
Operating temperature| °C| -20 to +50
Power Supply| –| External power supply (ref. 2437 – 2 out)
Power| –| 12V/300mA (DC over coax) (275mA – 2 in)
Dimensions| mm| 120 x 115 x 50
Power Supply| ref. 2437
---|---
Outputs| –| 2
Loss| dB| 4 – 5
Frequency range| MHz| 174 – 862
Isolation between outputs| dB| 10
DC output voltage| VDC| 12
Alimentation| V| 12 stabilized
AC input voltage/ frequency/ power| –| 110-240 VAC / 50-60 Hz / 6,5 W
Standard| –| EN50083-2
Output current| mA| 400 max.
Insulation class| –| II
Connectors| –| F-type Female
Operating temperature| °C| 0 to +50
Mounting| –| Mast or DIN rail (IP20)
Dimensions| mm| 95 x 76 x 35
The power supply is supplied only in the KIT version.
HARDWARE INSTALLATION
Installing the Smart Amp
- Connect your Terrestrial antennas to the Smart Amp*
- Connect the Smart Amp output to the Power Supply
- Connect your TVs to the Power Supply
Important:
Mount the module vertically to a wall in a well-ventilated room and leave a
minimum space of 15 cm around the product to guarantee maximum ventilation of
the product
The Smart Amp does not allow pass-through DC power for pre-amplifiers or active antennas
How Autoscan works:
- Plug-in Power Supply.
- The status LED will blink green when scanning.
- Status LED solid green when auto scan ready (This can take up to 20 seconds).
- Status LED red when error during the scan. Unpowered and repower within 6 seconds to restart the auto scan.
- WARNING: do not turn off the power during SCAN.
How to reprogram or force channel scan
- When a power outage causes missing channels on your TV, a reset is needed
- Reset: pull out the power supply and put it back in within 6 seconds
- The status LED will blink when re-scanning
- If a power interruption lasts longer than 6 seconds, there is no channel scan and the initial settings are kept
- Important note for installers! Do not cut the power plug and insert the power supply directly into a power cabinet/power strip. Make sure the end-user or installer can easily and safely unpower and repower the device.
LTE Filtering
LTE1 = LTE800 = 4G (REF. 7472L1) Everything above 790MHz is filtered out
:
LTE2 = LTE700 = 5G (REF. 7472L2) Everything above 694MHz is filtered out :
Duplicate channel switch OFF:
Weakest channel is rejected. See example below:
- CH30 > CH30
- ➔ CH30 is transmitted
- ➔ CH30 is rejected
- CH40 < CH40
- ➔ CH40 is rejected
- ➔ CH40 is transmitted
Duplicate channel switch ON:
Weakest channel is converted to LTE band. See example below:;
- CH30 > CH30
- ➔ CH30 is transmitted
- ➔ CH30 is converted to LTE band
- CH40 < CH40
- ➔ CH40 is converted to LTE band
- ➔ CH40 is transmitted
SAFETY INSTRUCTIONS
To prevent fire, short circuit or shock hazard:
- • Do not expose the unit to rain or moisture.
• Install the unit in a dry location without infiltration or condensation of water.
• Do not expose it to dripping or splashing.
• Do not place objects filled with liquids, such as vases, on the apparatus.
• If any liquid should accidentally fall into the cabinet, disconnect the power plug.
To avoid any risk of overheating:
- • Install the unit in a well-aired location and keep a minimum distance of 15 cm around the apparatus for sufficient ventilation
• Do not place any items such as newspapers, tablecloths, or curtains, on the unit that might cover the ventilation holes.
• Do not place any naked flame sources, such as lighted candles, on the apparatus
• Do not install the product in a dusty place
• Use the apparatus only in moderate climates (not in tropical climates)
• Respect the minimum and maximum temperature specifications
To avoid any risk of electrical shocks:
- • Connect apparatus only to socket with protective earth connection.
• The mains plug shall remain readily operable
• Pull out the power plug to make the different connections of cables
• To avoid electrical shock, do not open the housing of the adapter.
Maintenance
- Only use a dry soft cloth to clean the cabinet.
- Do not use solvent
- For repairing and servicing refer to qualified personnel.
Dispose of according to your local authority’s recycling processes.
CONDITIONS OF WARRANTY
Unitron N.V. warrants the product as being free from defects in material and
workmanship for a period of 24 months starting from the date of production
indicated on it. See note below.
If during this period of warranty the product proves defective, under normal
use, due to defective materials or workmanship, Unitron N.V, at its sole
option, will repair or replace the product. Return the product to your local
dealer for reparation.
THE WARRANTY IS APPLIED ONLY FOR DEFECTS IN MATERIAL AND WORKMANSHIP AND DOES NOT COVER DAMAGE RESULTING FROM:
- • Misuse or use of the product out of its specifications,
• Installation or use in a manner inconsistent with the technical or safety standards in force in the country where the product is used,
• Use of non-suitable accessories (power supply, adapters…),
• Installation in a defect system,
• External causes beyond the control of Unitron N.V. such as drops, accidents, lightning, water, fire, improper ventilation…
THE WARRANTY IS NOT APPLIED IF
- • Production date or serial number on the product is illegible, altered, deleted, or removed.
• The product has been opened or repaired by a non-authorized person.
NOTE
The date of production can be found in the product’s serial number code. The
format will either be “YEAR W WEEK” (e.g., 2017W32 = the year 2017 week 32) or
“YYWW” (e.g., 1732 = the year 2017 week 32).
UNITRON NV
Frankrijklaan 27 B-8970 Poperinge Belgium
T +32 57 33 33 63 F +32 57 33 45 24
sales@unitrongroup.com
www.unitrongroup.com.
References
- UnitronGroup: Your Partner for Customized IP & RF Solutions
- UnitronGroup: Your Partner for Customized IP & RF Solutions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>