johansson 6714 Profino Revolution Lite Amplifier User Manual
- June 3, 2024
- johansson
Table of Contents
6714 Profino Revolution Lite Amplifier
PATENTED TECHNOLOGY
SW Version 1.8.1.R
User Manual
6714 Orofino Revolution Lite Amplifier
No part of this manual may be copied, reproduced, transmitted, transcribed or
translated into any language without permission.
Unitrin reserves the right to change the specifications of the hardware and
software described in these manuals at any time.
Unitrin cannot be held liable for any damages resulting from the use of this
product. Specifications are subject to change without notice. 02/22
© Unitron – Frankrijklaan 27 – B-8970 Poperinge – Belgium
T +32 57 33 33 63 F +32 57 33 45 24
sales@unitrongroup.com
www.unitrongroup.com
INTRODUCTION
1.1. Product description
The Johansson Profino Revolution Lite is an easy to use programmable filter
amplifier and convertor for terrestrial signals. The module optimizes
terrestrial VHF/UHF signals from multiple inputs. The state-of-the-art
programmable filter amplifier has no equivalent on the market due to its
revolutionary technology:
- Smart & Automatic CHANNEL SCAN
- Can process and convert more than 50 channels (consisting out of 32 filters, each up to 6 MUXes wide)
- Can process S-Band output channels
- 5G LTE Protection (694MHz)
- Sharpest filters on the market (50 dB on adjacent channels)
- Real-time AGC on all individual multiplexes
- Complete flexibility in assigning filters from any input. Each channel can be frequency shifted to any other channel in the VHF or UHF band (Flex Matrix)
- To avoid unauthorized persons changing the settings, all Profiler products can be locked with a security code
- Made in Europe, for worldwide application
- 3 VHF/UHF inputs / 32 filters / AGC / 12-24 V remote power
- Powered via output F-connector
- Product dimensions (H X W X D): 165mm x 190mm x 59mm
1.2. Typical installation
The Orofino Revolution Lite can be used to provide high quality TV signals in
a wide range of projects, both in the hospitality as in the residential
market. Typical buildings
or infrastructures where the Orofino Revolution Lite can be used include, but
are not limited to:
- Large and small hotels, hostels, bed and breakfasts, holiday parks
- Hospitals, rest homes, prisons, settlements
- Large and small multi-dwelling units
1.3. Package contents
- 1 Orofino Revolution Lite (ref. 6714)
- Not included: Power Supply ref. 2438 (only included in KIT6714)
1.4. Hardware installation
FIGURE 1: TOP VIEW OF PRODUCT
1.5. Mounting the Orofino Revolution Lite
- Important: Mount the module vertically to a wall in a well-ventilated room and leave a minimum space of 15 cm around the product to guarantee a maximum ventilation of the product
- Connect an earth wire to the grounding clamp
- Connect the inputs to the Orofino Revolution Lite
- Connect a coaxial cable to the output connector for distribution of the signal
- Power the device via the output (use the Johansson Power Supply ref. 2438)
- Configure the device using the rotary button
1.6. Configuring the Profino Revolution Lite
NAVIGATING THROUGH THE MENU
Use the Johansson rotary/push button to navigate through the menu. This is
very straightforward and simple. The table below shows how the rotary/push
should be used:
| Push the button 2s to enter the basic configuration.
Push the button to confirm your selections.
---|---
| When rotating the button, you scroll through the different screens.
MENU OVERVIEW
REGION/COUNTRY SETTINGS
IMPORTANT! Before starting the configuration, it is advised to set the correct
region or country. Unpower the unit, push the button and keep pushing the
button while you repower the unit. Release the button when the display shows
“RESET FINISHED”. Now the product is reset and will ask you to enter country
or region. This will amongst others determine the channel plan for VHF and UHF
and the DC voltage for the inputs (12 or 24V).
DISPLAY READOUT | EXPLANATION |
---|---|
To activate the correct channel frequency plan, select the country or |
region where the Profiler Revolution Lite is situated. Rotate to select and
confirm by tapping the rotary button.
The default setting is Europe. The Profiler Revolution Lite is also
operational in the following countries/regions: Australia, Brazil, China,
Hongkong, Italia, New-Zealand, Russia, South Africa, UK and USA.All the
following menu items can be accessed without the reset procedure.
| Tap the rotary button to enter the channel scan menu
| Scroll down to START and tap the rotary button to start scanning
Note: If you use an active antenna or mast amplifier, activate the DC
before doing the Channel Scan (see next page: DC)
Scanning can take up to 1 minute
When scanning is finished, the number of detected channels will be displayed.
Manual changes can still be done afterwards via the Input settings (next
section) Tap the rotary button to proceed in the menu Sometimes, there can be
transponders on the same
frequency coming from different antennas (e.g. CH40 is detected on input 1 and
input 2). These are called duplicate channels.
DUPLICATCH = When duplicate channels is ON, the weakest of a pair of duplicate
channels will be transferred to the LTE band. The strongest of the pair keep
its frequency at the output.
| When duplicate channels is OFF, the weakest of a pair of duplicate channels
will be rejected.
When REPOWER is ON, the device will do a rescan after a power interruption of
6 seconds or less. If a power interruption takes longer than 6 seconds,
channel settings will not change.
When REPOWER is OFF, the device will never automatically rescan.
| Tap INPUT V/U 1 to enter the menu to configure input 1.
| Rotate the rotary button to scroll down in the submenu of INPUT V/U 1.
| PRE-AMPLI: The internal amplifier is by default ON, only in case of very
strong incoming signals (if the strongest channel on that input is higher than
80dBµV), it can be advised to switch this OFF.
| DC: Decide whether the input should provide power to an external amplifier.
Choose between OFF or 12 V.
Remark: If the external amplifier needs 24 V, you can change this in advanced
settings (see further).
| Tap Add Channel to add channel.
Up to 6 channels can be added at once.
| First select the starting channel (e.g. CH5) and tap to confirm. Then select
the stop channel (e.g. CH7, this means that you will add 3 channels). Tap to
confirm.
Then you can convert them using the rotary button (e.g. CH5 to CH7 converts to
CH8 to CH10) and tap to confirm.
| Some other examples:
To add CH5 and convert to CH6, select as follows:5:5 → 6:6
To add CH21-22-23 and convert to CH31-32-33, select as follows: 21:23 →
31:33
| Remark 1: The value 85dBµV (in the bottom right corner) indicates the
incoming level of the channel.
Remark 2: For EU, Italy and New-Zealand region, Channel 13 (230-240MHz) can be
used. CH13 cannot be converted.
Remark 3: A star (Û) will appear when converting to a different channel
bandwidth: e.g. from a 7MHz channel to an 8 MHz channel
For optimal performance we recommend to only add single channels, unless you
need to process a lot of channels.
| To add another (group of) channel(s), scroll down to ADD CHANNEL and tap to
confirm.
To prevent bad quality or scrambled images, make sure that only one input
channel is assigned to one output channel. If 2 channels are assigned to the
same output channel, a star (Û) will appear.
| The same applies for adding multiple channels. Make sure that each output
channel is selected only once.
To delete a (pair of) channel(s), position the arrow on the channel and press
the rotary button 3 seconds.
| To delete a (pair of) channel(s), position the arrow on the channel and
press the rotary button 3 seconds.
| When you have added all the channels to INPUT V/U 1, and you want to add
channels to the other inputs, scroll up to the top of the menu (to INPUT V/U
1), tap the button and scroll to the next input.
Repeat the previous steps for all input channels.
OUTPUT SETTINGS
DISPLAY READOUT | EXPLANATION |
---|---|
Define the OUTPUT LEVEL of the output signal. |
Range between 88 dB and 108 dB (default output level is 98 dB).
Note: The more channels you select, the less input power you should give (e.g.
99 dB for 10 channels).
| VHF ATTN : To compensate for cable losses, an attenuator of up to 15 dB
can be configured to decrease the VHF (up to 300MHz) output level (compared to
the UHF output level (above 300MHz)).
Note: In the OUTPUT menu, you define the output level in dB of the MUX’s. The
Profiler Revolution has enough gain to guarantee this output level under all
input conditions.
ADVANCED SETTINGS
| The language of the Profiler Revolution can be set to English, Italian,
Spanish or French.
| Tap REGION to check to which region/country the Profiler Revolution is set.
To change the region/country, a hard reset is required (see instructions above
(care. REGION/COUNTRY SETTINGS).
| Define DC VOLTAGE for the inputs, choose between 12V or 24V. This is a
global setting for all inputs, each input can then be switched between OFF or
this value.
(cfr. STEP 2). All countries are set by default on 24V, except UK which is set
by default on 12V.
The filter bandwidth can be changed from -2000 kHz to 0 kHZ in steps of 250
kHz.
This allows you to optimize the bandwidth of your filter.
For instance, a European 8 MHz channel can be changed from 6 to 8 MHz. The
default setting is -750 kHz, which is an optimal setting in 95% of the cases.
| S-Band channels can be activated in Advanced Mode.
By default, they are not activated.
See NOTE below for more explanation.
| Tap FW VERSION to check the firmware version of the device. Tap SERIAL
NUMBER to check the serial number of the device. To format the SD CARD, tap
FORMAT CARD.
Note: You can convert any single input Channel, to any output Channel position (including output S-channels). But you can only convert a group of input channels to a group of output channels with the same channel spacing.
Some examples:
21:23 → 31:33| Can be converted because groups of channels have same channel
spacing
---|---
07:07 → S15:15| Can be converted because single channel conversion
07:07 → S35:35| Can be converted because single channel conversion (Even
though channel spacing and bandwidth is different)
07:08 → S35:36| Can’t be converted because groups of channels have different
channel spacing
EXIT SETTINGS
DISPLAY READOUT | EXPLANATION |
---|---|
To avoid unauthorized people changing the settings, all Profiler products |
can be locked with a security code.
| Select LOCK and SET LOCK CODE.
When the lock code is set, the device will shut down.
| When you restart the device, you will now have to enter the correct lock
code.
Remark: If you forgot the lock code, you can always use the value 50. This
master code is fixed and cannot be changed.
If you do not want to work with a lock code, go to EXIT and tap NO LOCK.
TECHNICAL SPECIFICATIONS
Proofing Revolution Lite 6714
Inputs | – | 3 VHF/UHF (wideband) |
---|---|---|
Outputs | – | 1 main (VHF-S-UHF) |
Input frequency range (EU”) | MHz | |
MHz | VHF:174 – 240 |
UHF: 470 – 694
Output frequency range (EU’)| MHz| 174 – 862
LTE protection| MHz| 694 (5G)
Input level| dBμV
dBμV| VHF: 37″ – 109
UHF: 37″ -109
VHF/UHF Output power (60dBAM3) VHF/UHF Output power (36dBAM3) VHF/UHF Output
power with 1 MUX VHF/UHF Output power with 6 MUX VHF/UHF Output power with 15
MUX VHF/UHF Output power with 32 MUX| dBμV dBμV dBμV dBμV dBμV dBμV|
114125108108105000
Add channels| –| Per 1, 2, 3, 4, 5 or 6 Mixes’
Number of channels| –| More than 50 (32 filters)
Conversion| –| Yes (from any VHF-UHF channel
to any VHF-S-UHF channel)
Gain| dB
dB| VHF: >65
UHF: >65
Gain adjustment| dB| Channel AGC
General attenuator
VHF attenuator| dB
dB| 20
15
Noise figure| dB| 7
Selectivity| dB/1MHz| 50
Return Loss| dB| 10
Output MER| dB
dB| VHF: 35
UHF: 35
ESD protection| –| M Inputs
Remote voltage for preamp
Remote current| V
mA| 12 or 24
50 (total for the 3 Inputs)
Operating temperature| °C| -5 to +50
Power Supply| Voc| 12V (use ref. 2438)
Power consumption| W| 9
Dimensions| mm| 190 x165 x 59
Weight| kg| 0,65
- frequency range can vary slightly according to local channel plan (check REGION settings)
** For 64QAM with code rate 3/4
BLOCK DIAGRAM
SAFETY INSTRUCTIONS
Read these instructions carefully before connecting the unit
To prevent fire, short circuit or shock hazard:
- Do not expose the unit to rain or moisture.
- Install the unit in a dry location without infiltration or condensation of water.
- Do not expose it to dripping or splashing.
- Do not place objects filled with liquids, such as vases, on the apparatus.
- If any liquid should accidentally fall into the cabinet, disconnect the power plug.
To avoid any risk of overheating:
- Install the unit in a well aired location and keep a minimum distance of 15 cm around the apparatus for sufficient ventilation
- Do not place any items such as newspapers, tablecloths, curtains, on the unit that might cover the ventilation holes.
- Do not place any naked flame sources, such as lighted candles, on the apparatus
- Do not install the product in a dusty place
- Use the apparatus only in moderate climates (not in tropical climates)
- Respect the minimum and maximum temperature specifications
To avoid any risk of electrical shocks:
- Connect apparatus only to socket with protective earth connection.
- The mains plug shall remain readily operable
- Pull out power plug to make the different connections of cables
- To avoid electrical shock, do not open the housing of adapter.
Maintenance
Only use a dry soft cloth to clean the cabinet.
Do not use solvent
****For repairing and servicing refer to qualified personnel.
Dispose according your local authority’s recycling processes
CONDITIONS OF WARRANTY
Unitrin N.V. warrants the product as being free from defects in material and
workmanship for a period of 24 months starting from the date of production
indicated on it. See note below.
If during this period of warranty the product proves defective, under normal
use, due to defective materials or workmanship, Unitrin N.V, at its sole
option, will repair or replace the product. Return the product to your local
dealer for reparation.
THE WARRANTY IS APPLIED ONLY FOR DEFECTS IN MATERIAL AND WORKMANSHIP AND DOES NOT COVER DAMAGE RESULTING FROM:
- Misuse or use of the product out of its specifications,
- Installation or use in a manner inconsistent with the technical or safety standards in force in the country where the product is used,
- Use of non-suitable accessories (power supply, adapters…),
- Installation in a defect system,
- External cause beyond the control of Unitrin N.V. such as drop, accidents, lightning, water, fire, improper ventilation…
THE WARRANTY IS NOT APPLIED IF
- Production date or serial number on the product is illegible, altered, deleted or removed.
- The product has been opened or repaired by a non-authorized person.
NOTE
Date of production can be found in the product’s serial number code. The
format will either be “YEAR W WEEK” (e.g., 2017W32 = year 2017 week 32) or
“YYWW” (e.g., 1732 = year 2017 week 32).
UNITRON NV Frankrijklaan 27 B-8970 Papering Belgium
T +32 57 33 33 63 F +32 57 33 45 24
salesPunitronciroup.com
www.unitrongroup.com
Documents / Resources
|
johansson 6714 Profino Revolution Lite
Amplifier
[pdf] User Manual
6714 Profino Revolution Lite Amplifier, 6714, Profino Revolution Lite
Amplifier, Revolution Lite Amplifier, Lite Amplifier, Amplifier
---|---
|
johansson 6714 Profino Revolution
Lite
[pdf] User Manual
6714 Profino Revolution Lite, 6714, Profino Revolution Lite, Revolution Lite,
Lite
References
- UnitronGroup: Your Partner for Customized IP & RF Solutions
- UnitronGroup: Your Partner for Customized IP & RF Solutions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>