johansson 2436 Power Supply Instructions

October 27, 2023
johansson

johansson - logo KIT 7329
2436 Power Supply
Instructions

2436 Power Supply

7329 : UHF Preampliffer 15-32 dB
2436 : Power Supply

Safety instructions for power supply ref. 2436

Read carefully these instructions before connecting the unit.
The operating voltage is indicated on the nameplate of the housing.
To prevent fire, short circuit, shock hazard:
Do not expose the unit to rain or moisture.
Install the unit in a dry location without infiltration or condensation of water.
Do not expose it to dripping or splashing.
Do not place objects filled with liquids, such as vases, on the apparatus.
If any liquid should accidentally fall into the cabinet, disconnect the mains plug.
Refer to qualifed technician before it’s further operation.
To avoid any risk of overheating:
Install the unit in a well aery location and keep a minimum distance of 10 cm around the apparatus for suffcient ventilation.
Do not place any items such as newspapers, table-cloths, curtains … on the unit that might cover the ventilation holes.
The unit must not be exposed to any source of heat (sun, heater,…).
Do not place any naked flame sources, such as lighted candles, on the apparatus.
Do not install the product in a dusty place.
Pull out the mains plug to make the different connections of cables.
The mains plug has to remain readily operable.
To avoid electrical shock, do not open the housing.
Use the apparatus only in moderate climates (not in tropical climates).
Cleaning :
Only use a dry soft cloth to clean the cabinet.
Do not use solvent.
Servicing :
For repairing and servicing refer to qualifed personnel.

Technical specifications

2436

Outputs 2
Female F-type connectors
Insertion loss 4 – 5 dB
Protection between outputs 10 dB
Secondary DC power stabilized 24 V DC
Power 230 V~ ± 10%, 50 Hz / 4,6W
Effciency level VI
Output current 150 mA

Security
Overload and short circuit protected
Double isolated|
Dimensions| 95 x 76 x 35 mm

7329

Frequencies 470-694 MHz
Gain 15-32 dB
Noise fgure 3,5 dB
Max. input level 82 dBµV
Max. output level 104 dBµV
Power supply 24 VDC
Consumption 35 mA
Dimensions 120 x 115 x 50 mm.

Applicationjohansson 2436 Power Supply - fig Note: When connecting one output only, load the second output with 75 Ohm

UNITRON n.v.
Frankrijklaan 27
B-8970 Poperinge
Belgium
TEL +32 57 33 33 63 FAX +32 57 33 45 24
www.unitrongroup.com
e-mail : [email protected]

https://www.antares-sistemas.es

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

johansson User Manuals

Related Manuals