General instructions

Read this manual carefully before using this device. Keep this manual for future reference.

Meaning of symbols

The following warning symbols and/or signal words are used in this manual:

  • DANGER!
    This means an imminent danger due to electric current. Failure to follow the safety instructions can result in serious or fatal injury and/or serious damage to the product or environment.

  • WARNING!
    This means a dangerous situation due to UV-C radiation. Failure to follow the safety instructions can result in serious eye damage and damage to the skin.

  • WARNING!
    This means a dangerous situation. Failure to follow the safety instructions can result in moderate or minor personal injury and/or damage to the product or environment.

  • NOTICE!
    This means caution, useful information or advice.

  • Fig. … This refers to the relevant drawing … on pages 2 and 3 of this manual.

  • Meaning of the symbols on the device itself:

  • This UVC device produces harmful radiation, direct contact can be dangerous for the eyes and skin. Always turn off the UV lamp before opening.

  • This device complies with all applicable EU standards.

  • This device may not be disposed of with normal household waste but must be collected separately for recycling.

Use

Pressure filter with built-in UVC, suitable for ponds up to 36,000 litres.

  • The filter with UVC may only be used for cleaning pond water with a water temperature of at least 4°C to a maximum of 35°C. At water temperatures below or above these values, the device must be completely disconnected from the power supply.
  • If water inside the filter freezes, drain off the water and ensure that the filter is dry.
  • Do not use for filtration of salt water, sewage water, flammable, corrosive and/or explosive liquids (e.g. petroleum, petrol, solvents), fats, oils or foodstuffs.
  • The UVC device should only be switched on when there is sufficient water flow.
  • Never run the device without water.
  • Do not use for swimming pools and do not connect to drinking water supplies.
  • Place the filter in a dry and sheltered place. Not in direct sunlight.

Safety

Always follow the safety instructions below for safe use of the device. Failure to follow these instructions may endanger persons or the environment.

  • WARNING! This UVC device emits UV-C radiation, which can cause serious eye damage and/or damage to the skin. The UV lamp must therefore always be installed completely shielded from the eyes.
  • Never look at a burning UV lamp. Do not switch on the lamp until it is fully shielded installed and fully submerged.
  • This device must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
  • Ensure the voltage shown on the label matches the mains supply voltage.
  • This device must be connected to a socket which is earthed.
  • Protect the socket and plug against moisture. Use a drip loop to ensure that water cannot reach the socket via the cord
    ( see Fig. A ).

AQUADISTRI TopClear Pro 36000 Superfish Top Clear-fig2

  • Don’t use the product if the device, quartz glass, cord or plug is damaged. Replace the quartz glass or return the device to your dealer for repair or recycling.
  • If the power cord or plug is damaged, the electrical part should be replaced.
  • Be careful with the combination of water and electricity. Do not operate with wet hands. Dry hands before carrying out maintenance.
  • Always switch off all devices in the pond before maintenance. Disconnect the plug(s) from the socket.
  • NOTICE! The UV lamp becomes warm. Allow the lamp to cool for at least 10 minutes before carrying out maintenance.
  • In the event of frost or the risk of frost, appropriate precautions must be taken to prevent it from freezing.
  • This device can be used by children aged from 8 years and above, persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instructions concerning the use of the device in a safe way and understand the hazards involved. Children shall not play with the device. Cleaning and maintenance of the device shall not be done by children without supervision.
  • Modifications to the device may affect the safety. The warranty will also expire.
  • Aquadistri is not liable for any problems, damage or accidents due to incorrect use of this device.

Function

Water is pumped into the filter under pressure using a pond pump, a vortex movement forces water through a filter foam pack (mechanical filtration). At the bottom of the filter there are Bio-Balls which provide biological filtration. Useful bacteria convert harmful substances (ammonia and nitrite) to non-pollutants (nitrate). The water then flows up past the UV lamp. The UV lamp produces ultraviolet light with a wavelength of exactly 254 nm, at which wave length the disinfecting capacity is optimal. The UV radiation combats floating algae without the use of chemicals and reduces harmful bacteria and germs. The UV-C radiation does not affect the pH value of the pond water and is safe for fish and plants. The UVC device ensures a clear pond within 14 days. The filtered water flows back into the pond via a hose. The pressure filter has all the connections on the lid and can easily bridge any height differences, allowing it to be placed below the pond water level. The pressure filter can be buried almost completely into the ground or concealed next to the pond.

Installation

Locate the filter at least 2 metres away from the pond but easily accessible for maintenance.

  • NOTICE! The filter can be partially buried next to the pond but ensure that the cover and connections remain accessible.

  • When siting the filter, allow for a maximum bridgeable height difference of 2 metres.

  • Fig. B Release the outer retaining clamp (b) by undoing the double hinged lock, setting it aside.

  • Carefully remove the cover (c1+c2) including the integrated UVC device (quartz glass and UV lamp) from the filter housing (a) by pulling it upwards.

  • Remove the complete filter foam pack (d) and the filter bowl (f) with Bio-Balls (g) from the filter housing and rinse them with clean tap water.

  • Place the assembly back into the filter housing in the correct order, checking that the O-ring (e) is in the correct position in the rim of the filter housing.

  • Fig. C Carefully place the cover with the UVC back on the filter housing with the filter foam pack in the correct position.
    There is a mark (FIX ) on the cover plate (d1) of the filter foam pack and on the filter cover (c2), which should be vertically aligned to of each other when replacing. The white gear at the bottom of the cover fits precisely into the white recess in the filter foam pack.

  • Mount the three transparent hose connections (h) in the lid with gaskets on the inlet, outlet, and waste water outlet. You can choose between ø32 mm, ø38 mm or ø50 mm hose connections. Tighten the union nuts securely.

  • NOTICE! The hose connections on the inlet and outlet must be the same diameter.

  • Connect the pump to the inlet of the filter using pond hose and hose clamps. The pump should (preferably) be placed in the deepest point of the pond and able to provide a sufficient head of water.

  • NOTICE! Be sure to keep the maximum pump capacity to 15,000 l/h to avoid any damage to the filter and/or any leakage due to excessive pressure.

  • Connect a pond hose with hose clamp to the outlet, so that the water flows back into the pond.

  • Also connect a pond hose with hose clamp to the waste water drain.

  • Ensure that the blue lever (j) is on FILTER.

  • Switch on the pump and check for any leaks.

  • NOTICE! Never block or restrict the outlet of the filter. The pressure in the filter may become too high, causing the filter to leak or break.

  • Check the working of the UVC via the UV indicator (i) in the cover.

AQUADISTRI TopClear Pro 36000 Superfish Top Clear-fig2

UVC timer switch

The UVC timer switch (k) [24 hours/12 hours/0 hours] allows you to choose between constant operation of the UVC in summer, 12 hours of operation (per day) in spring and autumn, and you can switch off the UVC. This saves energy at times when the UVC is not needed and extends the service life of the UV lamp. The 12-hour on/12-hour off interval starts when you select this mode

Filter cleaning system with backwash function

You should clean the filter foam regularly, as dirt accumulates in the filter foam. When first installed, or if your pond is heavily soiled, it may be necessary to clean the filter foam daily. To do this, activate the automatic filter cleaning system, the filter foam pack rotates and is wrung out, the waste water drains away via the drain. There is no need to open the filter for this and an audible signal sounds when cleaning is complete.

  • Clean the filter foam as soon as the dirt indicator (l) shows, or clean it once a week.
  • Make sure a pond hose is connected to the waste water drain so the water can drain into the sewer or use it for watering the garden.
  • Set the blue lever (j) to CLEAN, after which the UVC will switch itself off, the filter foam pack will rotate and the water will be diverted via the waste water drain.
  • As soon as the audible signal sounds or the rinse water is clear again, move the blue lever back to FILTER. The filter foam pack stops rotating, the UVC switches back on and the filter operates normally again.
  • Check that the water flows into the pond through the outlet and the flow rate is sufficient.

Maintenance of the filter

If the flow rate remains insufficient after automatically cleaning the filter foam, you should clean or replace the filter foam manually. To do this, dismantle the filter foam pack (d).

  • First, unplug the filter and the pump.

  • Remove the outer clamp (b) and carefully remove the cover (c) with the UVC from the filter housing (a).

  • Remove the filter foam pack from the filter housing.

  • Fig. D Scan the QR code for the instruction video explaining how to disassemble the filter foam pack.

  • Fig. E Clean the Bio-Balls once or twice a year by rinsing them with pond water. Do not use tap water for this purpose.
    The trays (f) containing the Bio-Balls can be easily opened by turning turning the black slatted cover anticlockwise and lifting it off. In the same way, you can also take off the upper tray.

  • Place the whole assembly back into the filter housing in the correct order, check that the O-ring (e) is in the correct position in the rim of the filter housing. Replace the cover with the UVC in the correct position and close the outer clamp.

  • Turn the pump and filter back on by plugging in the plugs.

Maintenance of the UVC

  • Check monthly if UV lamp is burning via the UV indicator (i).

  • Remove the plugs of the filter and the pump from the socket before carrying out maintenance!

  • The outside of the quartz glass (q) should be cleaned twice a year.

  • Remove the outer clamp (b) and carefully remove the cover (c) with the UVC from the filter housing (a).

  • Carefully clean the quartz glass outer face with a soft cloth and SuperFish Pump & UVC Clean. After cleaning, thoroughly rinse the quartz glass with clean tap water and check for damage. Replace the quartz glass if it shows any damage (to prevent glass breakage). Quartz Glass Replacement Kit for TopClear Pro 36000 (Art. 06030135).

  • As soon as algae growth increases, check the UVC device and UV-lamp and exchange the UV lamp (m) as needed.

  • The UV-lamp should be replaced annually, as the lamp may still show active but no longer emits enough UV radiation (maximum 8000 operating hours). Replacement lamp for TopClear Pro 36000 UVC: SF UV PL-lamp 55 W 2G11-535 mm (Art. 06011040).

  • The lamp is hot, wait 10 minutes after switch off before opening the UVC device.

  • Fig. F Loosen the two metal screws (r) in the cover and remove the cover plate (c2).

  • Loosen the cable connection (s) of the UVC, unscrew the union nut and pull the plug out of the mating plug.

  • Turn the lamp holder (n) anti-clockwise and gently pull the lamp holder with the UV lamp upwards out of the quartz glass.

  • Remove the old UV-lamp (m) with the lamp clip (p) from the fitting of the lamp holder.

  • Insert the new UV-lamp in the fitting and put the clip on the UV-lamp.

  • Carefully slide the UV lamp back into the quartz glass, check the position of the O-ring (o1) and tighten the lamp holder in a clockwise direction.

  • Fig. G To replace the quartz glass (q), first remove the lamp holder with the UV lamp.

  • Loosen the four screws (t) from the top of the quartz glass and remove the old quartz glass.

  • Insert the new quartz glass with both O-rings (o1+o2).

  • NOTICE! The quartz glass can only be inserted in one way. There is a recess in the plastic part of the quartz glass and a cam in the opening for the quartz glass (on the side of the blue lever).

  • Make sure the cam falls into the recess and tighten the screws (crosswise) firmly so that the quartz glass seals everything and makes it watertight.

  • Check the operation of the UVC via the UV control window after you have reinstalled the UV lamp, cable connection, cover, etc. and switched-on the filter and pump.

Recycling

This symbol indicates that this product (if it is discarded) may not be disposed of with normal household waste. Instead it must be handed in at an official collection centre (e.g. HWRC). Or can be returned to the dealer when purchasing a similar new product. Follow the applicable rules in your country for the separate collection of electrical and electronic products.
Separate collection and recycling are better for the environment, public health and reduces waste.

Warranty

2 years manufacturer’s warranty on materials and construction defects. Devices must be returned complete with all components, accompanied with an official proof of purchase confirming a purchase date for any warranty claims. Incomplete devices of which parts are missing, and devices without proof of purchase are not eligible for warranty. After receiving and checking, we will determine whether the device will be repaired or replaced. For a device repaired or replaced under warranty, the remaining time of the original warranty period applies. Carefully read the instructions on installation, use and maintenance. Damage due to incorrect use, damage due to contamination or not cleaning the device, glass breakage and damage to the cord are not covered by the warranty. Always keep the proof of purchase, without proof of purchase the warranty will be void!

Important, clean you UVC device at least twice a year!

Dirt and calcification reduce the UV-light permeability. Descale your quartz glass at least twice a year, for a smooth, long-term use. In areas with extremely hard water you may need to descale more often. Technical problems caused by scale are not under warranty. For cleaning and descaling the quartz glass special SuperFish Pump & UVC Clean is available at your dealer.