POTTER SPKSTR-24WLP Series Wall Mount Low Profile Speaker Strobe Instruction Manual
- June 9, 2024
- POTTER
Table of Contents
POTTER SPKSTR-24WLP Series Wall Mount Low Profile Speaker Strobe
MODELS
- *SPKSTR-24WLP. . . . . . . . . . . . . . .** WALL MOUNT SPEAKER WITH SELECTABLE STROBE
- *SPKSTR-24-AL . . . . . . . . . . . . . . . .** WALL MOUNT SPEAKER WITH SELECTABLE STROBE, ALERT TEXT
- *CSPKSTR-24-AL. . . . . . . . . . . . . . .** WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, AMBER LENS, ALERT TEXT
- *CSPKSTR-B-AL . . . . . . . . . . . . . .** .WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, BLUE LENS, ALERT TEXT
- *CSPKSTR-G-AL . . . . . . . . . . . . . .** WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, GREEN LENS, ALERT TEXT
- *CSPKSTR-R-AL . . . . . . . . . . . . . . .** WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, RED LENS, ALERT TEXT
- *CSPKSTR-24-AL-WP . . . . . . . . . . .** OUTDOOR WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, AMBER LENS, ALERT TEXT
- **CSPKSTR-B* – AL-WP . . . . . . . . . . . .** OUTDOOR WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, BLUE LENS, ALERT TEXT
- *CSPKSTR-G-AL-WP. . . . . . . . . . . .** OUTDOOR WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, GREEN LENS, ALERT TEXT
- *CSPKSTR-R-AL-WP. . . . . . . . . . . .** OUTDOOR WALL MOUNT SPEAKER WITH FIXED 15/75 CANDELA STROBE, RED LENS, ALERT TEXT
- Includes one or more of the following designators: P (plain – no text), R (red) or W (white)
INTRODUCTION
- The Potter Electric SPKSTR and CSPKSTR Series is a high quality speaker/strobe. The high intensity strobe utilizes a Xenon flash tube that generates a high-intensity flash visible from all angles.
- The SPKSTR-24WLP and SPKSTR-24-AL is provided with a turn dial which allows for candela selection at the installation site; 15Cd, 30Cd, 60Cd, 75Cd, or 110Cd. The CSPKSTR-24-AL, CSPKSTR-B-AL, CSPKSTR-G-AL, CSPKSTR-R-AL, CSPKSTR-24-AL-WP, CSPKSTR-B-AL-WP, CSPKSTR-G-AL-WP, CSPKSTR-R-AL-WP are fixed candela units, available in 15/75 candela intensity only. This appliance is ideal for any occupancy that requires notification appliances per the applicable building or fire code or wherever dependable alarms are required.
- The SPKSTR-24WLP and SPKSTR-24-AL speaker/strobe strobe is listed in compliance with ANSI/UL 1971, Signaling Appliances for the Hearing Impaired. The CSPKSTR-24-AL, CSPKSTR-B-AL,
- CSPKSTR-G-AL, CSPKSTR-R-AL, CSPKSTR-24-AL-WP, CSPKSTR-B-AL-WP, CSPKSTR-G-AL-WP, CSPKSTR-R-AL-WP strobe is listed in compliance with ANSI/UL 1638, Visual Signaling Appliances – Private Mode Emergency and General Signaling.
PRODUCT INFORMATION
- The SPKSTR and CSPKSTR Series Series speaker/strobe offer a choice of field selectable power taps, 1/8, 1/4, 1/2, 1, 2 and 4 Watts for use with either 25VRMS or 70.7VRMS audio amplifiers.
- The frequency range of the speakers is 400-4000Hz. All devices are suitable for line supervision. Speaker includes DC blocking capacitor which allows for supervision voltage of either polarity.
LOCATION
- This appliance is intended for use in Fire Alarm Systems and is to be installed in accordance with this manual, the recommendation of the local authorities having jurisdiction, and other NFPA documents that provide standards on notification appliances for protective signaling systems. The SPKSTR-24WLP, SPKSTR-24-AL, CSPKSTR-24-AL, CSPKSTR-B-AL, CSPKSTR-G-AL,
- CSPKSTR-R-AL, are intended for indoor installations only; this appliance is not listed for outdoor or drip proof applications. The CSPKSTR-24-AL-WP, CSPKSTR-B-AL-WP, CSPKSTR-G-AL-WP,
- CSPKSTR-R-AL-WP are intended for indoor or outdoor installations; this appliance is listed for outdoor or drip proof applications when used in conjunction with the SPKRBB back box.
WARNING
-
The visual signal must be installed within 16 feet of the pillow when used in a sleeping area.
-
The visual signal must be in the direct viewing area of the occupant in order to be seen.
-
The visual signal can not be seen when objects such as doors, furniture, or walls block the visual signal.
-
NOTICE: VISUAL SIGNALS FOR THE HEARING IMPAIRED ARE ONLY ONE METHOD OF ALERTING THE HEARING
IMPAIRED. VISUAL SIGNALS MAY NOT BE THE PREFERRED METHOD FOR NOTIFYING ALL HEARING IMPAIRED
INDIVIDUALS. -
NOTICE: THE VISUAL SIGNAL MUST BE SEEN BY THE SLEEPING PERSON. IF THE PERSON HAS THEIR HEAD TURNED OR
OTHERWISE UNABLE TO BE ALERTED BY VISUAL, THE VISUAL SIGNAL WILL NOT BE EFFECTIVE.
WARNING
- Visual Signal should NEVER be relied upon as the primary fire alert for the hearing impaired under these common sense conditions:
- a. Sleeping face down on the bedding or pillow
- b. Use of sleep medications of any kind
- c. Use of alcoholic beverages or recreational drugs
- d. Use of eye shades
- e. If there are tendencies of deep sleep conditions
- f. If a fire cuts power to AC circuits, the visual signal will not operate
- g. If person is not within line of sight of visual signals
- Under these and other similar common situations an alternate fire alert method such as a non-hearing impaired attendant is needed. The visual signal only increases the chance of being alerted to the presence of fire. No system of this type can fully protect the hearing impaired in case of fire.
Room Spacing for Wall-Mounted Visible Appliances per NFPA 72, 2013 Edition
Maximum Room Size| Minimum Required Light Output ( Effective Intensity, Cd)
Meters| Feet| One Light per Room| Four Lights per Room (One Light per Wall)
6.10 x 6.10| 20 x 20| 15| NA
8.53 x 8.53| 28 x 28| 30| NA
9.14 x 9.14| 30 x 30| 34| NA
12.2 x 12.2| 40 x 40| 60| 15
13.7 x 13.7| 45 x 45| 75| 19
15.2 x 15.2| 50 x 50| 94| 30
16.5 x 16.5| 54 x 54| 110| 30
16.8 x 16.8| 55 x 55| 115| 30
18.3 x 18.3| 60 x 60| 135| 30
19.2 x 19.2| 63 x 63| 150| 37
20.7 x 20.7| 68 x 68| 177| 43
21.3 x 21.3| 70 x 70| 184| 60
24.4 x 24.4| 80 x 80| 240| 60
27.4 x 27.4| 90 x 90| 304| 95
30.5 x 30.5| 100 x 100| 375| 95
33.5 x 33.5| 110 x 110| 455| 135
36.6 x 36.6| 120 x 120| 540| 135
39.6 x 39.6| 130 x 130| 635| 185
- LIGHT OUTPUT IN PERCENTAGE WHEN MEASURED EROM THE FOLLOWING DIRECTIONS PER UL1971
Effective Intensity Requirements for Sleeping Areas
- Visible Notification Appliance
- Distance from Ceiling to Top of Lens Intensity
- greater than or equal to 24 ” 110cd
- less than 24 ” 177cd
- LIGHT OUTPUT IN PERCENTAGE WHEN MEASURED FROM THE FOLLOWING DIRECTIONS PER UL1638
ELECTRICAL SPECIFICATIONS
CLEAR Lens Strobe Current Ratings
Use with SPKSTR-24 and SPKSTR-24-AL Products
Candela| Regulated 24VDC Max. Operating Current (mA)| Regulated 24VFWR Max.
Operating Current (mA)
15| 78| 113
30| 96| 135
60| 137| 186
75| 180| 245
110| 224| 313
Model| Color Lens
---|---
CSPKSTR-24-AL / CSPKSTR-24-AL-WP| AMBER
CSPKSTR-B-AL / CSPKSTR-B-AL-WP| BLUE
CSPKSTR-G-AL / CSPKSTR-G-AL-WP| GREEN
CSPKSTR-R-AL / CSPKSTR-R-AL-WP| RED
COLORED Lens Strobe Current Ratings
*Fixed 15/75 Candela Strobe**
Use with CSPKSTR-24-AL, CSPKSTR-24-AL-WP, CSPKSTR-B-AL, CSPKSTR-B-AL-WP,
CSPKSTR-G-AL, CSPKSTR-G-AL-WP, CSPKSTR-R-AL and CSPKSTR-R-AL-WP Products
Lens Color| Regulated 24VDC Max. Operating Current (mA)| Regulated 24VFWR Max.
Operating Current (mA)
Amber| 148| 395
Blue| 280| 274
Green| 360| 479
Red| 397| 438
- The SPKSTR-15/75-AL, SPKSTR-24WLP-WP CSPKSTR-24-AL, CSPKSTR-24-AL-WP, CSPKSTR-B-AL, CSPKSTR-B-AL-WP, CSPKSTR-G-AL, CSPKSTR-G-AL-WP, CSPKSTR-R-AL, and CSPKSTR-R-AL-WP has a fixed candela rating of 15/75 per ANSI/UL 1638.
- NOTICE: DC VOLTAGE RANGE LIMITS: 16-33V. FWR VOLTAGE RANGE LIMITS: 16-33V. THIS PRODUCT WAS ONLY TESTED TO THE STATED VOLTAGE RANGE(S); DO NOT APPLY 80% AND 110% OF THIS RANGE FOR SYSTEM OPERATION.
Field Selectable Power Tap Selection – Reverberant (dBA @ 10ft.)
Voltage| 1/8 Watt| 1/4 Watt| 1/2 Watt| 1 Watt| 2
Watt| 4 Watt
25 Volts| 74.6| 77.7| 80.5| 83.1| 85.6| 87.9
70.7 Volts| 73.7| 76.7| 79.6| 82.5| 85.4| 87.9.
SYSTEM CONSIDERATIONS
- To select the proper wattage input for the speaker, move the jumper to the appropriate pin.
- Always maintain electrical isolation between speaker and strobe wiring on combination units.
- Do not exceed 130% of rated speaker voltage. If excessive distortion is heard, check amplifier for signal clipping. If clipping exists, reduce either amplifier input or gain.
- Four screws are provided, two for securing speaker to the back box and two for aesthetics. The two non-functional screws will be held in place by the pressure fit of the faceplate
- CAUTION: WHEN INSTALLING, ROUTE FIELD WIRING AWAY FROM SHARP PROJECTIONS, CORNERS AND INTERNAL COMPONENTS.
- NOTICE: DO NOT USE LOOPED WIRE UNDER TERMINALS. BREAK WIRE RUN TO PROVIDE SUPERVISION OF CONNECTION.
- MAX. WIRE DISTANCE (IN FEET) =
- PANEL VOLTAGE – DEVICE MINIMUM VOLTAGE TOTAL CURRENT DRAW
- X WIRE CONDUCTIVITY (STROBE ONLY)
- INCLUDES WIRE TO AND FROM APPLIANCE.
- ASSUMES ALL APPLIANCES ARE AT THE END OF WIRE RUN (WORST CASE).
- CAUTION: APPLIES ONLY TO REGULATED SUPPLIES.
- NOTICE: ALL STROBES ARE DESIGNED TOFLASH AS SPECIFIED WITH CONTINUOUS APPLIED VOLTAGE. THIS APPLIANCE IS NOT RECOMMENDED FOR USE ON CODED OR PULSING SIGNALING CIRCUITS. HOWEVER, USE OF THE AVSM CONTROL MODULE IS PERMITTED TO SYNCHRONIZE THE STROBE.
- NOTICE: REFERENCE AVSM CONTROL MODULE MANUAL (550-0598, DATED 2-1-13) FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM MANUAL CAN BE OBTAINED BY CALLING POTTER ELECTRIC SIGNAL COMPANY AT 1-800-325-3936.
MOUNTING ROUGH-IN BOX AND RUNNING WIRING
- MOUNTING – SPEAKER/STROBE
- TO SPKRBB BACK BOX
- For use with SPKSTR-24WLP,
- SPKSTR-24-AL,
- CSPKSTR-24-AL,
- CSPKSTR-B-AL,
- CSPKSTR-G-AL, and CSPKSTR-R-AL
- Series product.
MOUNTING – SPEAKER/STROBE TO 4” SQUARE x 2 1/8” DEEP METALLIC BACK BOX
- For use with SPKSTR-24WLP,
- SPKSTR-24-AL,
- CSPKSTR-24-AL,
- CSPKSTR-B-AL,
- CSPKSTR-G-AL, and CSPKSTR-R-AL
- Series product.
- For use with
- CSPKSTR-24-AL-WP,
- CSPKSTR-B-AL-WP,
- CSPKSTR-G-AL-WP, and CSPKSTR-R-AL-WP Series product.
- NOTICE: USE FOR WALL MOUNT APPLICATIONS ONLY.
MOUNTING – OUTDOOR SPEAKER/STROBE
- For use with
- CSPKSTR-24-AL-WP,
- CSPKSTR-B-AL-WP,
- CSPKSTR-G-AL-WP, and CSPKSTR-R-AL-WP Series product.
- NOTICE: USE FOR WALL MOUNT APPLICATIONS ONLY
FIELD SELECTABLE CANDELA SELECTOR
Adjust power taps using needle nose pliers.
FOR SPKSTR-24WLP AND SPKSTR-24-AL PRODUCT ONLY
Adjust intensity by inserting small flat blade screwdriver to turn dial.
Displayed number will indicate selected candela.
NOTICE: FIELD SELECTABLE OPTIONS OF 15, 30, 60, 75 AND 110 CANDELA.
CHECKOUT AND TROUBLESHOOTING
- Supply power to the system control panel. The auxiliary signaling device should not be activated.
- If the signal is activated:
- a. Check all smoke and fire detectors in the system to make sure they have not been activated.
- b. Check all wiring connections to make sure the signal detection circuits are not reversed or shorted together. Check wire color codes and traces.
- To test the speaker or speaker/strobe product series and other signaling appliances, trip the auxiliary panel, activate alarm circuit at the main control panel or activate one of the fire detection units in the system. All auxiliary signals should be activated.
- An operational test on this product should be conducted in accordance with National Standards or at a minimum annually and more often if dictated by local and state codes or authorities having
jurisdiction.
- SIGNALING APPLIANCE LIMITATIONS:
- Your speaker meets or exceeds current audibility requirements of ANSI/UL 1480. However, if the appliance is located outside a bedroom it may not wake up a sound sleeper, especially if the room door is closed or only partially open.
WARNING
THIS APPLIANCE WILL NOT OPERATE WITHOUT ELECTRICAL POWER. AS FIRES FREQUENTLY
CAUSE POWER INTERRUPTIONS,
POTTER ELECTRIC SUGGESTS YOU DISCUSS FURTHER SAFEGUARDS WITH YOUR LOCAL FIRE
PROTECTION SPECIALIST
TO RETURN AN APPLIANCE
Should you experience problems with your appliance, proceed as follows:
-
Turn off electrical power to the auxiliary alarm circuit.
-
Unscrew the unit from the mounting box.
-
Disconnect the unit from the field wiring. Reconnect the two positive supply voltage circuits (red wires) and the two negative supply voltage circuits (black wires) of the auxiliary alarm circuit to
maintain power to the other auxiliary alarm appliances in the system. -
Carefully pack the defective unit (the manufacturer cannot be responsible for consequential damage due to shipping or mishandling). Include your return address and complete details as to the
nature of the difficulties being experienced and date of installation. -
Return to: Potter Electric Signaling Company, LLC 1609 Park 370, Hazelwood, MO 63042. Prior to returning, call the Potter Electric field service department at 1-800-325-3936 to obtain a RMA number.
ADDITIONAL INSTRUCTIONS FOR WALL MOUNT LOW PROFILE SPEAKER AND SPEAKER/STROBE: CAN/ULC
- This appliance is ideal for any occupancy that requires notification appliances per the applicable building or fire code or wherever dependable alarms are required. This appliance is listed in compliance with CAN/ULC S526 and/or CAN/ULC S541. This appliance offers a choice of field selectable power taps, 1/8, 1/4, 1/2, 1, 2 and 4
- Watts for use with either 25VRMS or 70.7VRMS audio amplifiers. The frequency range of the speakers is 400-4000Hz. All devices are suitable for line supervision. Speaker includes DC blocking capacitor which allows for supervision voltage of either polarity. All wiring is to be in accordance with CSA C22.1 Canadian Electrical Code, Part 1,
- Safety Standard for Electrical Installations, Sec. 32. This appliance is intended for use in fire alarm systems and is to be installed in accordance with this manual, the
- National Building Code of Canada, CAN/ULC S524 and local codes that provide standards on notification appliances for protective signaling systems. Potter Electric recommends spacing notification appliances in compliance with CAN/ULC S524.
Field Selectable Power Tap Selection – Anechoic (dBA @ 3 meters) Output Sound Pressure Level (OSPL)
Voltage| 1/8 Watt| 1/4 Watt| 1/2 Watt| 1 Watt| 2
Watt| 4 Watt
25 Volts| 79.4| 82.4| 85.2| 87.9| 90.7| 93.9
70.7 Volts| 78.8| 81.9| 84.6| 87.6| 90.5| 93.4
Directional Sound Characteristic:
Wall Mount Speaker and Speaker/Strobe
| Horizontal Angle
-3 dBA| 60
-6 dBA| 20
| Vertical Angle
-3 dBA| 55
-6 dBA| 10
LIMITED WARRANTY
-
For a period of 60 months from the date of manufacture (or as long as required by applicable law), Potter Electrical Signal Company, LLC warrants to you the original purchaser that your appliance will be free from
defects in workmanship and materials under normal use and service. -
This warranty does not apply and is void if damage or failure is caused by: accident, abuse, misuse, abnormal use, faulty installation, liquid contact, fire, earthquake or other external cause; operating the appliance outside Potter Electrical Signal Company, LLC’s published guidelines; or service, alteration, maintenance or repairs performed by anyone other than
Potter Electrical
- Signal Company, LLC. This warranty also does not apply to: consumable parts, such as batteries; cosmetic damage, including but not limited to scratches or dents; defects caused by normal wear and tear or otherwise due to the normal aging of the appliance, or if any serial number has been removed or defaced from the appliance.
- TO THE EXTENT PERMITTED BY LAW, THIS WARRANTY AND THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL, WRITTEN, STATUTORY, EXPRESS OR IMPLIED. POTTER ELECTRICAL SIGNAL COMPANY, LLC DISCLAIMS ALL STATUTORY AND IMPLIED WARRANTIES, INCLUDING WITHOUT
- LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND WARRANTIES AGAINST HIDDEN OR
- LATENT DEFECTS TO THE EXTENT PERMITTED BY LAW. TO
- THE EXTENT SUCH WARRANTIES CANNOT BE DISCLAIMED, SUCH IMPLIED WARRANTIES SHALL APPLY ONLY FOR THE WARRANTY PERIOD SPECIFIED ABOVE. PLEASE NOTE THAT SOME STATES (COUNTRIES AND PROVINCES) DO NOT ALLOW LIMITATION ON HOW LONG AN IMPLIED WARRANTY (OR CONDITION) LASTS. SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. EXCEPT AS PROVIDED IN THIS WARRANTY AND TO THE EXTENT PERMITTED BY LAW, POTTER ELECTRICAL SIGNAL COMPANY, LLC WILL NOT BE LIABLE FOR ANY DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION, OR ARISING IN CONNECTION WITH THE SALE,
- USE OR REPAIR OF THE APPLIANCE, OR UNDER ANY OTHER LEGAL THEORY, INCLUDING BUT NOT LIMITED TO LOSS OF USE, LOSS OF REVENUE, LOSS OF ACTUAL OR ANTICIPATED PROFITS,
- LOSS OF THE USE OF MONEY, LOSS OF BUSINESS, LOSS OF OPPORTUNITY, LOSS OF GOODWILL, AND LOSS OF REPUTATION. THE MAXIMUM LIABILITY OF POTTER ELECTRICAL SIGNAL COMPANY, LLC SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE PAID BY YOU FOR THE APPLIANCE. PLEASE NOTE THAT SOME STATES (COUNTRIES AND PROVINCES) DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
- CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
- If a defect in workmanship or materials causes your appliance to become inoperable within the warranty period, you must return the appliance to Potter Electrical Signal Company, LLC postage prepaid to: Potter Electrical Signal Company, LLC, 1609 Park 370, Hazelwood MO 63042. You must prove to the satisfaction of Potter Electrical Signal Company, LLC the date of purchase of your appliance. You must also enclose a return address. Warranty service may only be performed by Potter Electrical Signal Company, LLC personnel at Potter Electrical Signal Company, LLC’s facilities in Hazelwood, Missouri. You must also pack the appliance to minimize the risk of it being damaged in transit. If we receive an appliance in a damaged condition as the result of shipping, we will notify you and you must seek a claim with the shipper.
- If you submit a valid claim to Potter Electrical Signal Company, LLC during the warranty period, Potter Electrical Signal Company, LLC will, at its option, repair your appliance or furnish you with a new or rebuilt appliance without charge to you except for postage required to return the appliance to us. Potter Electrical Signal Company, LLC will not reimburse you for repairs or replacement parts provided by other parties. Your repaired or replacement appliance will be returned to you free of charge and it will be covered under the warranty for the balance of the warranty period, if any. When a product or part is replaced, any replacement item becomes your property and the replaced item becomes property of Potter Electrical Signal Company, LLC. For additional warranty and product information go to www.pottersignal.com.
- THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE (OR BY COUNTRY OR PROVINCE). BY THIS WARRANTY,
- POTTER ELECTRICAL SIGNAL COMPANY, LLC DOES NOT LIMIT OR EXCLUDE YOUR RIGHTS EXCEPT AS ALLOWED BY LAW. TO FULLY
- UNDERSTAND YOUR RIGHTS, YOU SHOULD CONSULT THE LAWS OF YOUR COUNTRY, PROVINCE OR STATE.
Important Notice:
These materials have been prepared by Potter Electrical Signal Company, LLC
(“Potter”) for informational purposes only, are necessarily summary, and are
not purported to serve as legal advice and should not be used as such. Potter
makes no representations and warranties, express or implied, that these
materials are
complete and accurate, up-to-date, or in compliance with all relevant local,
state and federal laws, regulations and rules. The materials do not address
all legal considerations as there is inevitable uncertainty regarding
interpretation of laws, regulations and rules and the application of such
laws, regulations and rules to particular
fact patterns. Each person’s activities can differently affect the obligations
that exist under applicable laws, regulations or rules. Therefore, these
materials should be used only for informational purposes and should not be
used as a substitute for seeking professional legal advice. Potter will not be
responsible for any action or failure to act in reliance upon the information
contained in this material.
-
Potter Electric Signal Company, LLC
-
1609 Park 370, Hazelwood, MO 63042
Documents / Resources
|
POTTER SPKSTR-24WLP Series Wall Mount Low Profile Speaker
Strobe
[pdf] Instruction Manual
SPKSTR-24WLP Series Wall Mount Low Profile Speaker Strobe, SPKSTR-24WLP
Series, Wall Mount Low Profile Speaker Strobe, Low Profile Speaker Strobe,
Speaker Strobe
---|---
References
- Fire Alarm Resources | Download fire alarm documents
- Potter Electric: Fire Alarms & Fire Sprinkler Systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>