Midea KJ500G-TB32 Air Purifier User Manual

June 4, 2024
Midea

Midea KJ500G-TB32 Air Purifier

Safety Warning

Safety Precautions

Notes
This section describes the contents and importance of safety matters to prevent personal injuries or property damages to the users or others. Please read the text on the basis of full understanding of the following contents, and be sure to abide by the safety matters as described.

  • Do not use this appliance in wet or high-temperature environments (like bathroom, toilet and kitchen).

  • Before replacing the filter, please stop this appliance and cut off power.

  • Do not place other items on top of the appliance, and forbid sitting or standing on this appliance.

  • Please use the original filter provided by the factory. In case of other filters, the best results cannot be achieved.

  • Do not use damaged or aged power cords; Forbid replacing the power cord without authorization. If the power cord is
    damaged, it must be replaced by the manufacturer, its service department or a professional from similar department to avoid danger

  • This appliance is only subject to 220-240V power supply, and please unplug the power cord when it is not used for a long time.

  • Do not insert the fingers or objects into the air inlets or air outlets to prevent the product from physical damages or malfunction.

  • Please unplug the power cord immediately and contact the service center in time when the appliance suffers abnormal sound or burnt smell or smoke.

  • Matters that may Cause Minor Injury or Property Damages

  • Do not spray flammable substances near the appliance; Do not spray water directly on the appliance or use chemical cleaners like alcohol or hydrochloric acid, etc.; Do not place water containers, medicines, or flammable materials on the appliance.

  • Do not block the air inlets/outlets of the appliance with any item;

  • This appliance cannot replace natural ventilation and other appliances like a vacuum cleaner, kitchen ventilators, etc.

  • When the appliance is working, it must be placed on a dry, flat and stable floor, with at least 30cm space reserved around it.

  • Do not put it in a place with direct sunlight.

  • To prevent electromagnetic disturbance, the appliance must keep a certain distance from the TV, radio, microwave oven and others. The mist produced by the ultrasonic humidifier may affect the

  • PM2.5 detection of this appliance, and both should maintain a certain distance.

  • Do not disassemble or modify this appliance without authorization to avoid accidents.

  • Do not pull the power cord to move the appliance.

  • Please take care of the children and make sure that the children do not touch the appliance to avoid accidents.

Notes

  • The pictures contained in the Manual are for reference only, and please be subject to the physical product in the packing box

Name of components

Midea-KJ500G-TB32-Air-Purifier-
fig-1
Assembly Instructions

  1. Take down the air inlet grill
  2. Take out the Pre-Filter
  3. Press the U-shaped buckle to pull outward, and take out the Pre-Filter
  4. Take out the HEPA filter Hold both sides of the HEPA filter with both hands, and take out the HEPA filter

Midea-KJ500G-TB32-Air-Purifier-fig-2

  1. Assemble the HEPA filter
  2. Assemble the early Pre-Filter Align the slot position at the bottom, and buckle up the upper U-shaped buckle
  3. Assemble the air inlet grill Align the slot position at the bottom, press both sides of the upper part of the air inlet grill, and buckle up the air inlet grill
  4. Assemble the filter on the other side Repeat Steps 1-7 to assemble the filter on the other side, and then power on for operation

Midea-KJ500G-TB32-Air-Purifier-fig-3

Operating Manual

Control panelMidea-KJ500G-TB32-Air-Purifier-fig-4

Trial operation

Notes

  • This appliance is provided with a disassembly protection function; the appliance can only operate normally after the air inlet grill and air outlet grill are assembled properly.
  • In case of continuous electricity, enter the working mode before the standby state, after each power on.
  • The appliance is connected to the power again after unexpected power outage (when the power is off or the power cord is unplugged during normal operation), and then restores to the working state before the power outage.
  1. Preparations
    Power on for the first time, the display panel flashes for 1s, and then the screen is turned off. The whole appliance is the standby state;

  2. Switch
    Press the On/Standby Button

  3. Pre-heating
    The VOC sensor is preheated, Excellent; Medium and Poor are displayed alternately, and then displayed normally after 1min
    The particle sensor enters the preheating state, PM2.5 displays “- – -” ; Medium and Poor are displayed alternately, and then displayed normally after 10s;

  4. Work
    The purifier is powered on for the first time and then enters the Auto mode.

Cleaning and Maintenance

Body cleaning

Notes
Be sure to turn it off before any maintenance, and cut off power.Midea-
KJ500G-TB32-Air-Purifier-fig-9

Cleaning of the filter components
  1. When the last bar of the progress bar turns red and the cleaning indicator light is on, it prompts that the Pre-Filter needs to be cleaned
  2. Unplug the power cord, and take out the Pre-Filter
  3. Vacuum up dust with a vacuum cleaner or wipe it with a cloth
  4. If there is a lot of dirt, the common diluted kitchen detergent is used to soak, and then clean itMidea-KJ500G-TB32-Air-Purifier-fig-10
  5. Dry the Pre-Filter
  6. Assemble the Pre-Filter
  7. Plug the power cord, and start up
  8. Long press the PM2.5 detection button for 3s, the cleaning indictor light is off, and the Pre-Filter is restored.Midea-KJ500G-TB32-Air-Purifier-fig-11
Replacement of the filter components
  1. Filter model: FC-50JA-1A (includes 2)
  2. When the last bar of the progress bar turns red and the replacement indicator light is on, it prompts that the HEPA filter needs to be replaced
  3. Take out the HEPA filterMidea-KJ500G-TB32-Air-Purifier-fig-12
  4. Remove the protective film of the filter
  5. Assemble the HEPA filter
  6. Long press the PM2.5 detection button for 3s, the cleaning indictor light is off, and the Pre-Filter is restored.
  7. Midea-KJ500G-TB32-Air-Purifier-fig-13

Service Guide

Faults Handling
Notes
Please confirm the following contents before the entrusted maintenance

Product parameters

|
---|---
Model| KJ500G-TB32
Rated power| 220-240V
Rated power| 35W
CADR (particulate matters)| 500m3/h

Purification energy efficiency rating of the particulate matters

|

Efficient level

Noise

|

< 56dB

  • The various performance parameters in the table are measured in the factory and for reference only.

  • If the appliance is modified, the parameters may be changed, and please be subject to the parameters on the nameplate.

  • Purification principle: The fan of the air purifier draws air into the body for filtrating through the built-in filter element, which plays a main role in filtering the dust (like PM2.5, etc.), formaldehyde, odor, sterilization and so on.

Environment-friendly List

Midea-KJ500G-TB32-Air-Purifier-fig-15

This table is formulated in line with the SJ/T 11364
“○” indicates that the contents of China RoHS controlled substances or elements in all homogeneous materials are below the limits as specified in GB/T26572;
“×” indicates that the contents of China RoHS controlled substances or elements in all homogeneous materials exceed the limits as specified in GB/T26572;

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals