legrand 0 489 53-54 Presence Sensors For 1 Circuit User Guide
- May 15, 2024
- Legrand
Table of Contents
Presence sensors for 1 circuit
for working areas with natural light
0 489 53-54 Presence Sensors For 1 Circuit
Selection chart p. 887
Technical characteristics p. 891
Check presence and light level continuously, switch-OFF when there is
sufficient natural light Occupancy mode (automatic switch-ON/OFF factory
setting)
Can be used with push-button Cat.No 2 780 40L (p. 1173) (or illuminated push-
button Cat.No 0 770 33) (p. 1173) for vacancy mode (manual switch-ON and
manual or automatic switch-OFF)
Infrared and ultrasonic Lighting Management sensors for workplaces, allowing
precise presence detection as soon as the wave transmitted by the sensor is
modified (for example, by hand movement on a keyboard)
Precise on-site adjustment using configuration tool (p. 890)
Pack | Cat.Nos | Ideal for working areas – small spaces |
---|---|---|
1 | 48806 | Suitable for meeting room, classroom, open space, etc. |
Dual technology ceiling-mounting Lighting Management sensors, 360° Infrared
and ultrasonic detection Range Ø8m IP 20 3-wire with neutral
Optimum distance between 2 sensors: 6 m Standby consumption: 0.8 W
Fix directly to afalseceiling with mounting claws (included) or installed in a
Batibox box, depth 50 mm (p. 810)
Connection via automatic terminals
Can be surface-mounted in ceiling using accessory Cat.No 0 488 75 (p. 890)
Mini-head PIR ceiling-mounting Lighting
Management sensors, 360° IP 40, range Ø7m Recommended installation height: 2.8
m 3-wire with neutral connection to power supply Can be installed on surface
with dedicated
accessoryincludedinthebox
1| 48953| DALI dimming sensor with a relay for switching an additional load
Maximum number of DSI or DALI ballasts: 10 Stand by consumptio n0.3W
1| 48966| 1-10Vdimmingsensor+1ON/OFFoutput6A
Maximum number of ballasts: 10 Standby consumption: 0.6 W
1| 48954| ON/OFF presence sensor
Standby consumption 0.8 W
PIR ceiling-mounting Lighting Management
sensors, 360°
IP 40
3-wire with neutral
Tobeinstalledwithclaws(supplied)
Connection via screw terminals
1| 48964| DALIdimmingsensor+1ON/OFFoutput10A
Range Ø7m
Maximum number of DSI or DALI ballasts :20
1| 48965| 1-10V dimmin gsensor+1ON/OFFoutput10A Range Ø7m
Maximum number of ballasts: 10
PIR ceiling-mounting Lighting Management ensors, 360° IP 40
3-wire with neutral
To be installed with claws (supplied) Connection via screw terminals
1| 48968| DALI dimming sensor + 1 ON/OFF output 10 A Range 15m
Maximum number of DSI or DALI ballasts: 20
1| 48969| 1-10 V dimming sensor + 1 ON/OFF output 10 A Range 15 m
Maximum number of ballasts: 10
1| 48970| ON/OFF presence sensor 2 outputs 6A
Ideal for offices
1| 48804| PIR ceiling-mounting Lighting Management sensor, 360° Range 8 m
3-wire with neutral
Optimum distance between 2 sensors: 6 m Standby consumption: 0.8 W
Fix directly to a false ceiling with mounting claws (included) or installed in
a Batibox box, depth 50 mm (p. 810)
Can be surface-mounted in ceiling using accessory Cat.No 0 488 75 (p. 890)
With an additional 2 A contact for HVAC control, based on presence data
Examples of solutions for classroom, open-space office and meeting room
Mosaic presence and motion sensors, p. 1176
Red catalogue numbers: New products
Documents / Resources
|
legrand 0 489 53-54 Presence Sensors For 1
Circuit
[pdf] User Guide
0 489 53-54 Presence Sensors For 1 Circuit, 0 489 53-54, Presence Sensors For
1 Circuit, Sensors For 1 Circuit, 1 Circuit
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>