IMPORTANT INSTRUCTIONS

THIS HEATER REQUIRES HARDWIRE INSTALLATION (NO PLUG). THE INSTALLATION OF THIS PRODUCT MUST BE CARRIED OUT BY A CERTIFIED ELECTRICIAN AND IN ACCORDANCE WITH ALL LOCAL AND NATIONAL ELECTRICAL CODES.

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

  1. Read all instructions before installing or using this heater.
  2. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as electrical cords, furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9 m) from the front of the heater and keep them away from the sides and rear.
  3. Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
  4. Always turn off the power to the heater when not in use.
  5. Do not operate any heater after the heater malfunctions, has been dropped or damaged in any manner. Disconnect power at the service panel and have the heater inspected by a reputable electrician before reusing.
  6. Do not use outdoors.
  7. This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. Never locate heater where it may fall into a bathtub or other water container.
  8. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire, or damage the heater.
  9. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where openings may become blocked.
  10. heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.
  11. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons.
  12. To disconnect heater, turn controls to off, and turn off power to heater circuit at main disconnect panel.
  13. If the red alarm light on the front of the unit illuminates, immediately turn the heater off and inspect for any objects on or adjacent to the heater that may have blocked the airflow or otherwise caused high temperatures to have occurred.
    DO NOT OPERATE THE HEATER WITH THE ALARM LIGHT ILLUMINATING.

PET OWNERS WARNING: The health of some small pets including birds are extremely  sensitive to the fumes produced during the first-time use of many appliances. These fumes are not harmful to humans but we recommended that you do not use your heater around birds and small pets during its initial use until the manufacturing protective coatings burn off.

SAVE THESE INSTRUCTIONS

WARNING

This Product can expose you to chemicals including Disononyl phthalate (DINP) which is known to the State of California to cause cancer and Di-isodecyl phthalates (DIDP) which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.p65Warnings.ca.gov

SPECIFICATIONS

5000W III 240 1 60 20.9 17065
3700W III 208 1 60 17.8 12624
4000W II 240 1 60 16.7 13648
3000W II 208 1 60 14.4 10236
3000W I 240 1 60 12.5 10236
2260W I 208 1 60 10.9 7711

SAFETY INFORMATION

WARNING:

THIS HEATER REQUIRES HARDWIRE INSTALLATION (NO PLUG). THE INSTALLATION OF THIS PRODUCT MUST BE CARRIED OUT BY A CERTIFIED ELECTRICIAN AND IN ACCORDANCE WITH ALL LOCAL AND NATIONAL ELECTRICAL CODES.
NOTE: COMPATIBLE WITH A 240V LINE VOLTAGE DOUBLE POLE WALL THERMOSTAT. MUST BE INSTALLED BY A CERTIFIED ELECTRICIAN.

READ AND UNDERSTAND ALL INSTALLATION & OPERATION INSTRUCTIONS PRIOR TO OPERATING THIS UNIT. OBSERVE ALL SAFETY INSTRUCTIONS.

  1. Use only copper wires rated for at least 60ºC.
  2. Heater air flow must be directed parallel to or away from adjacent wall.
  3. Observe all wall, floor and ceiling clearance requirements.
  4. All wiring must be done according to national and local electrical codes. The heater must be grounded as a precaution against possible electrical shock. Heater circuit must be protected with proper fuses.
  5. The mounting structure and the anchoring hardware must be capable of supporting the weight of the heater and the mounting bracket (if used)
  6. All electrical power must be disconnected at the main service box, which must be locked before connecting, inspecting, cleaning or servicing the heater. This is an important precaution to prevent serious electric shock.
  7. This is heater is not suitable for use in hazardous locations containing explosive liquids or vapours. This heater has hot or arcing or sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids are used or stored.
  8. This heater is not suitable for use in corrosive atmospheres such as marine greenhouses or chemical storage areas.
  9. This heater must be mounted at least 8 feet off the floor. For specific clearances, see figure 2
    Safety Instruction

WARNING:

IMPROPER INSTALLATION OR FAILURE TO FOLLOW THE PROCEDURES OUTLINED IN THIS INSTRUCTION MANUAL CAN RESULT IN SERIOUS ELECTRICAL SHOCK

Install heater away from traffic areas, maintaining clearances stated in figure 2 (below). The air flow direction should not be restricted (ie. by columns or machinery). The air flow should wipe exposed walls rather than blowing directly on them. When more than one heater is used in an area, heaters should be installed so that the air discharge of each heater supports the air flow of the others, to provide best warm air circulation as shown in figure 3.

LOCATING HEATER

Safety Instruction

PRE-INSTALLATION

**

Pre installation**

Part Description Quantity
A Garage Heater 1
B Mounting Bracket 1
C Screw 3
D Washer 6

INSTALLATION

MOUNTING THE BRACKET
Refer to Figures 4a and 4b
Installation Instruction
Figure 4a. Single-Screw Mounting
_ Installation Instruction
_ Figure 4b. Double-Screw Mounting

  1. Locate a wood stud in the wood ceiling joist/side wall. For ceiling only, if you cannot locate a wood stud, you have to install a wood piece on the ceiling as this heater must be securely fastened.
  2. Remove the mounting bracket from the heating unit by loosening bracket screws with a wrench and slipping the handle off over the screw heads.
  3. Place a washer on screws before inserting through the holes in the mounting bracket and screw them securely into a ceiling joist or wall stud.
    NOTE: If you want to swivel the heater either to the right or left adding a washer to both sides of the bracket is recommended. A longer lag bolt may be required to properly secure the unit.

HANGING THE HEATER

  1. Attach the heating unit to the mounting bracket.
  2. Lift the heater up and into the mounting bracket.
  3. Align the bracket screws with the keyhole slots in the mounting bracket.
  4. Tighten the bracket screws with a wrench so the unit is securely suspended at horizontal or vertical level.
  5. The heater can be mounted with different angles listed in the drawing on as long as you maintain proper clearance listed on

ADJUSTING AIR FLOW DIRECTION

  1. To turn the unit when it has been installed with a single lag bolt (as shown in figure 4a) , simply turn the entire heater as needed. The unit cannot be turned horizontally if it has been installed with 2 lag bolts.

  2. To tilt the unit vertically, loosen the bracket screws (see figure 5).
    HANGING THE HEATER

  3. Adjust louvers to the desired position (see Figure 6).
    HANGING THE HEATER

NOTE: The louvers are designed so they cannot be completely closed. Do not attempt to bypass this feature; damage to the unit can result.

WARNING:

TO PREVENT POSSIBLE ELECTRIC SHOCK, DISCONNECT POWER TO THE HEATER AT THE MAIN SERVICE BOX BEFORE ATTEMPTING TO ADJUST THE HEAT OUTPUT OF THIS UNIT.

MULTIPLE VERTICAL ANGLES
Installation Instruction

CONNECTING THE POWER

Connecting the Power
Connecting the Power

WARNING: DISCONNECT POWER BEFORE SERVICING

If you will use an external temperature control (external thermostat) to control
the heater, please follow below attention points:

  1. Make sure that the heater’s temperature control knob (thermostat knob) is turned fully clockwise.

  2. Connect the wire according to below wiring diagram.
    wiring diagram.
    CONNECTING THE POWER

  3. The external temperature control (external thermostat): a certified thermostat must be used.

  4. The lead wire of external temperature control (external thermostat) can not be less than 14AWG.

TO PROTECT THE HEATING ELEMENT

When starting the heater, turning the temperature control clockwise slowly to desired heat setting, the unit starts the fan first then starts the heating element. When shutting off the heater, turning the temperature control counter-clockwise to off, both the fan and the heating element turn off at the same time.

WARNING:

THIS APPLIANCE MUST BE GROUNDED! THE APPLIANCE MUST CONNECT TO A CURRENT PROTECTION CIRCUIT OR DEVICE BEFORE BEING CONNECTED TO POWER SUPPLY!

  1. Remove the screw from the front of the unit to connect the power to the heater.

  2. Attach the cable connectors to the unit (See Figure 7). Select power supply wire to comply with local and national electric codes using heater rating given on the rating label.
    NOTE: All wiring must be carried out by a Certified Electrician and must be in accordance to national and local electrical codes. For certain applications, conduit may be required, See Figure 7. Check local electrical codes. If you run the wiring in conduit and wish to be able to turn the heater be sure to purchase enough flexible conduit to allow the heater to be turned.

  3. Connect the wire to the power block located in the base of the heater – See Figure 7.
    Installation Instruction
    Figure 7:

  4. Turn on the power at the main service.

WARNING:

HIGH TEMPERATURES – RISK OF FIRE. KEEP FLAMMABLE MATERIALS, SUCH AS FURNITURE, PILLOWS, BEDDING, PAPERS, CLOTHES, ELECTRICAL CORDS AND CURTAINS AT LEAST 3 FT. (0.9 M) FROM THE FRONT AND TOP OF THE HEATER AND KEEP THEM AWAY FROM THE SIDES AND REAR. TO REDUCE THE RISK OF FIRE, DO NOT USE IT IN AREAS WHERE GASOLINE, PAINT OR FLAMMABLE LIQUIDS ARE USED OR STORED.

WARNING:

TO REDUCE THE RISK OF FIRE, DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THE HEATER.

CONNECTING THE POWER
Connecting the Power

OPERATING INSTRUCTIONS

WARNING:
THE HEATER MUST BE PROPERLY INSTALLED BEFORE IT IS USED.
Operating Instuction
Check that the garage heaters outlet grill is not covered or obstructed in anyway, and make sure the power to the unit is switched on.

SETTING THE THERMOSTAT

  1. Rotate thermostat knob clockwise to desired position, POWER INDICATOR will turn yellow.
  2. After room reaches desired comfort level the heater will turn off. Heater will cycle on and off to maintain room temperature.

SELECTION SWITCH
Using the SELECTION SWITCH, you can control the heating output: I for 3000W, II for 4000W, III for 5000W

THERMAL CUT-OUT
The heater will automatically shut off when parts of it overheat. The heater will turn ON again when the abnormal temperature returns to normal levels. Should the unit overheat and cause the thermal cut-out to cycle, the cause of the overheating must be determined and corrective action taken before further operation.

CAUTION:

WHEN THE THERMAL CUT-OUT IS ACTIVATED, THE CAUTION INDICATOR WILL TURN RED. IN THIS CASE, IMMEDIATELY TURN THE HEATER OFF AND INSPECT FOR ANY OBJECTS ON OR ADJACENT TO THE HEATER THAT MAY CAUSE HIGH TEMPERATURES. DO NOT TAMPER WITH ANY OF THE CONTROLS. DO NOT OPERATE THE HEATER WITH  THE CAUTION INDICATOR GLOWING RED.

MAINTENANCE

  1. Before cleaning, make sure the power has been turned off at the circuit breaker panel and that the heating element of the heater is cool.
  2. To maintain the external appearance of the heater, the unit occasionally needs to  be wiped with a dry duster. During the summer months, or at other times when the appliance is not in use and is completely cold, it should be the wiped over with a damp cloth.
  3. Do not use abrasive cleaning powders or furniture polish. Do not use chemical or abrasive products, metallic scourers and so on, which may deteriorate the surface, to clean the appliance.
  4. During the summer months, or at other times when the appliance is not in use, disconnect the power supply. Keep the appliance in a dry and cool place.
  5. All other servicing should be performed by qualified service personnel. Do not try to repair the heater yourself

NOTE: The motor is permanently lubricated, and no further lubrication is needed.

REPLACEMENT PARTS

Part Description Part#
1 Back mesh EG5000001AC
2 Hanging plate EG5000002AC
3 Fan Blade EG5000003AC
4 Air guide plate EG5000004AC
5 Large handle seat EG5000005AC
6 Small handle seat EG5000006AC
7 Spring EG5000007AC
8 Motor EG5000008AC
Part Description Part#
--- --- ---
9 Heater EG5000009AC
10 Switch EG5000010AC
11 Selection Switch EG5000011AC
12 Thermostat EG5000012AC
13 Knob EG5000013AC
14 Terminal block EG5000014AC
15 Temperature CUT-OFF EG5000017AC
16 Caution Indicator (Red) EG5000018AC
17 Power Indicator (Yellow)

EG5000019AC

Replacement Parts

TROUBLESHOOTING

PROBLEM ROOT CAUSE CORRECTIVE ACTION
Unit is not heating. The overheat protection has activated. Inspect the

garage heater and check that the air inlets and outlets are not blocked as this may cause overheating. Switch off the circuit breaker to the garage heater for 30 minutes and allow it to cool down. Turn the power back on and operate.
The breaker has tripped| Reset the breaker at the fuse panel and restart the heater
The room temperature has already reached the set thermostat temperature| Adjust the temperature setting to make sure the thermostatsetting temperature is higher than current room temperature.
Garage heater emits a burning smell| During production dust and/ or oil debris gathered on heating coils.| Make sure the room is well ventilated. Allow the garage heater to run until the smell is dissipated.
Check and make sure there is no combustible material within 0.9 meters (3 feet) of the garage heater.| Remove the combustible material around the garage heater.
This heater must be mounted at least 8 feet off the floor, for specific clearances, please checkthe “LOCATING HEATER”section in the instruction manual| Relocate the garage heater so there is enough space between the heater and adjacent wall and floor.

Warranty

LIMITED WARRANTY:
This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale.GHP Group, Inc., at it’s option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group,Inc., within one (1) year of retail purchase. (Shipping costs, labour costs,etc. are the responsibility of the purchaser.)

DUTIES OF THE OWNER:
This heating appliance must be operated in accordance with the written instructions furnished with this heater. This warranty shall not excuse the owner from properly maintaining this heater in accordance with the written instructions furnished with this heater. A bill of sale, canceled check or payment record must be kept to verify purchase data and establish warranty period. Original carton should be kept in case of warranty return of unit.

WHAT IS NOT COVERED:

  1. Damage resulting from use of improper fuel.
  2.  Damage caused by misuse or use contrary to the owners manual and safety guidelines.
  3. Damage caused by a lack of normal maintenance.
  4. Fuses
  5. Use of non-standard parts or accessories.
  6. Damage caused in transit. Freight charges on warranty parts or heaters to and from the factory shall be the responsibility of the owner.

This warranty does not imply or assume any responsibility for consequential damages that may result from the use, misuse, or the lack of routine maintenance of this heating appliance. A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of maintenance. This warranty does not cover claims which do not involve defective workmanship or materials. FAILURE TO PERFORM GENERAL MAINTENANCE (INCLUDING CLEANING) WILL VOID THIS WARRANTY.

THIS LIMITED WARRANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE. THE REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES. IN NO EVENTWILL GHP GROUP, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you.

CLAIMS HANDLED AS FOLLOWS:

  1.  Contact your retailer and explain the problem.
  2. If the retailer is unable to resolve the problem, contact our Customer Service Dept. detailing the heater model, the problem, and proof of date of purchase.
  3. A representative will contact you. DO NOT RETURN THE HEATER TO GHP GROUP, INC. unless instructed by our Representative. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Warranty

WARRANTY REGISTRATION

IMPORTANT: We urge you to fill out your warranty registration card within fourteen (14) days of date of purchase. You can also register your warranty on the internet at
www.ghpgroupinc.com. Complete the entire serial number. Retain this portion of the card for your records.

COSTUMER SUPPORT

GHP Group, Inc.
6440 W Howard St
Niles, IL 60714-3302″
Tel: (877) 447-4768
www.ghpgroupinc.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals