Dyna-Glo FA40DGP-01 Propane Construction Heater Owner’s Manual

June 7, 2024
Dyna-Glo

PROPANE
CONSTRUCTION HEATER

USER’S MANUAL AND OPERATING INSTRUCTIONS

Dyna-Glo™DELUX
MODELS| RMC-FA40DGD
RMC-FA50DGD
RMC-FA60DGD
RMC-FA100DGD
RMC-FA125DGD/LPFA125DGD
RMC-FA150DGD| (40,000 BTU/HR,                 FORCED – AIR)
(30,000/50,000 BTU/HR,     FORCED – AIR)(30,000/60,000 BTU/HR,     FORCED – AIR)(70,000/100,000 BTU/HR,   FORCED – AIR)(70,000/125,000 BTU/HR,   FORCED – AIR)(120,000/150,000 BTU/HR, FORCED – AIR)
---|---|---
Dyna-Glo™Pro MODELS:| RMC-FA40/DGP/DGP-01 RMC-FA50/DGP/DGP-01 RMC- FA60/DGP/DGP-01 RMC-FA100/DGP/DGP-01 RMC-FAl25/DGP/DGP-01 LPFAl25H/LPFAl25H-01 RMC-FA150/DGP/DGP-01| (40,000 BTU/HR, FORCED – AIR)
(30,000/50,000 BTU/HR, FORCED – AIR) (30,000/60,000 BTU/HR, FORCED – AIR) (70,000/100,000 BTU/HR, FORCED – AIR) (70,000/125,000 BTU/HR, FORCED – AIR)(120,000/150,000 BTU/HR, FORCED -AIR)
---|---|---

GENERAL HAZARD WARNING

FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH  THIS HEATER, CAN RESULT IN  EATH,  SERIOUS BODILY INJURY AND PROPERTY LOSS, OR DAMAGE FROM THE HAZARDS OF FIRE, EXPLOSION, BURN.  ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER.

IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTION MANUAL, LABELS, ETCETERA, CONTACT THE MANUFACTURER.

CONSUMER: Retain this manual for future reference.
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 877-447-4768 8:30 a.m. – 4:30 pm CST, Monday – Friday
or email us at customerservice@ghpgroupinc.com
www.ghpgroupinc.com
Printed in China

IMLPFDG – GDK

WARNING : FIRE, BURN, INHALATION, AND EXPLOSION HAZARD, KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING  ATERIALS, PAPER, OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS.
NEVER USE THE HEATER IN SPACES THAT DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS  SUCH AS GASOLINE, SOLVENTS, PAINT THINNERS, DUST PARTICLES, OR UNKNOWN CHEMICALS.

CALIFORNIA PROPOSITION 65: Fuels used in gas or oil-fired appliances and the products of combustion of such fuels contain chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. This product contains chemicals, including lead and lead compounds, known to the State of California to cause cancer, birth defects, or other reproductive harm. Wash hands after handling.

WARNING: Using this heater in a residential garage requires that the heater is positioned so that it is protected against any possible damage by a moving vehicle, etc. It must be positioned so that the base of the heater is no less than 18 in (450 mm) above the garage floor or 8 ft (2450 mm) in repair garages. The heater must be placed on a stable surface. Do not place it on a chair, ladder, etc. Raising the heater will reduce BUT NOT eliminate the possibility of lighting the vapor of any flammable liquids which may be improperly stored or accidentally spilled. If the smell of gasoline is present, DO NOT operate this heater until the area has been properly ventilated.

WARNING : CONSTRUCTION HEATERS ARE NOT FOR USE IN GARAGES IN CANADA.

WARNING : NOT FOR HOME OR RECREATIONAL VEHICLE USE.

NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!

PROPANE CONSTRUCTION HEATER

DYNA-GLO PROPANE FORCED AIR CONSTRUCTION HEATERS
The heater is designed and approved for use as a construction heater under ANS Z83.7 CSA 2.14. It is hard to anticipate every use which may be made of this heater. CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS. Other standards govern the use of fuel gases and heat-producing products in specific applications. Your local authority can advise you about these.

IMPORTANT : READ THIS USER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO OPERATE OR SERVICE THIS  HEATER. IMPROPER USE OF THIS HEATER CAN CAUSE SERIOUS INJURY OR DEATH FROM FIRE, EXPLOSION, AND CARBON MONOXIDE POISONING.
This is a direct-fired forced air construction heater for either indoor construction or outdoor use. Its intended use is primarily the temporary heating of buildings or structures under construction, alteration, or repair. All the products of combustion generated by the heater are forced through the heater and released into the area being heated. This heater operates at approximately 98%+ combustion efficiency but still produces a small amount of carbon monoxide. Humans can tolerate small amounts of carbon monoxide for short periods. Carbon monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning or death.

WARNING : NOT FOR USE WITH DUCTWORK.

SPECIFICATIONS

__**Model No.| RMC-­‐FA40DGP/ DGP-­‐01| **FA50 Series| ** **FA60 Series| RMC-­‐FA100DGD/ DGP/DGP-­‐01| LPFA125DGD/ RMC-­‐FA125DGP/ DGP-­‐01| LPFA125H/H-­‐01/ RMC-­‐FA125DGD| __**RMC-­‐FA150DGD
---|---|---|---|---|---|---|---
**Input Rating| ** ** 40,000 BTU/hr| 30,000 BTU/hr

50,000 BTU/hr

| 30,000 BTU/hr

60,000 BTU/hr

| 70,000 BTU/hr

100,000 BTU/hr

| 70,000 BTU/hr

125,000 BTU/hr

| 70,000 BTU/hr

125,000 BTU/hr

| 120,000 BTU/hr

150,000 BTU/hr

__**Type of Gas| Propane| Propane| Propane| Propane| Propane| Propane| Propane
**Gas Supply Pressure to Regulator Maximum| __ Cylinder Pressure| __ Cylinder Pressure| __ Cylinder Pressure| __ Cylinder Pressure| __ Cylinder Pressure| __ Cylinder Pressure| __ Cylinder Pressure
__**Minimum (for purpose of Input Adjustment)| 5psig| 5psig| 5psig| 5psig| 5psig| 5psig| 5psig
**Manifold Pressure| __ 11″ W.C| __ 11″ W.C| __ 11″ W.C| __ 11″ W.C| __ 11″ W.C| __ 11″ W.C| __ 11″ W.C
__**Gas Consumption| 1.9lbs/hr| ** 0.86 kg/hr| 1.4lbs/hr 2.3lbs/hr| 0.63 kg/hr

1.04 kg/hr

| 1.4lbs/hr 2.8lbs/hr| 0.63 kg/hr

1.27 kg/hr

| 3.3lbs/hr 4.6lbs/hr| 1.5 kg/hr

2.09 kg/hr

| 3.3lbs/hr 5.8lbs/hr| 1.5 kg/hr

2.63 kg/hr

| 3.3lbs/hr 5.8lbs/hr| 1.5 kg/hr

2.63 kg/hr

| 5.6lbs/hr 7.0lbs/hr| 2.54 kg/hr 3,18 kg/hr
__**Electrical Input| 120V, 60Hz, 1Ø| 120V, 60Hz, 1Ø| 120V, 60Hz, 1Ø| 120V, 60Hz, 1Ø| 120V, 60Hz, 1Ø| 120V, 60Hz, 1Ø| 120V, 60Hz, 1Ø
**Amperage| __**Load| 0.68amps| 0.65amps| 0.65amps| 0.7amps| 0.7amps| 0.7amps| 0.7amps
__**

Fan

| Unload Load| 3550rpm 3000rpm| 3570rpm 3300rpm| 3570rpm 3300rpm| 3580rpm 3300rpm| 3580rpm 3300rpm| 3580rpm 3300rpm| 3580rpm 3300rpm
__**Ignition| Piezo/Manual Spark| Continuous Spark| Continuous Spark| Continuous Spark| Continuous Spark| Continuous Spark| Continuous Spark
**Spark Gap| __ 0.16″ (4mm)| __ 0.16″ (4mm)| __ 0.16″ (4mm)| __ 0.16″ (4mm)| __ 0.16″ (4mm)| __ 0.16″ (4mm)| __ 0.11″ (2.8mm)
__**Size (LxWxH)| 19.3″x8.3″x15.2″ (49.0×21.1×38.6)cm| 19.3″x8.3″x15.2″ (49.0×21.1×38.6)cm| 19.3″x8.3″x15.2″ (49.0×21.1×38.6)cm| 25.6″x12.7″x15.6″ (65.0×32.3×39.6)cm 25.6″x11.8″x16.1″ (65.0×30.0x40.9)cm| 26.6″x13.0″x17.3″ (67.6×33.0x43.9)cm 25.6″x11.8″x16.1″ (65.0×30.0x40.9)cm| 26.2″x11.8″x17.2″ (66.6×30.0x43.6)cm 25.6″x11.8″x16.1″ (65.0×30.0x41.0)cm| ** 25.6″x11.8″x16.1″ (65.0×30.0x40.9)cm

PROPANE CONSTRUCTION HEATER

GENERAL SAFETY INSTRUCTION
Accidents are always tragic especially because so many of them could have been prevented with little care and judgment. There are some basic good practices, we hope you will follow for safe use of your heater.

IMPORTANT SAFETY INSTRUCTION

  • Children should be carefully supervised when they are in the area.
  • Always maintain proper clearance from combustible materials. Minimum clearance from combustibles: Side – 24” (61 cm); Top – 36” (92 cm); Front – 72” (183 cm). Floor – combustible. Not for use on finished floors.
  • Heater must be placed on a level and stable surface.
  • Never place anything including clothes or other flammable items on the heater.
  • The appliance area shall be kept clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
  • Do not modify or operate a heater that has been modified.
  • Adequate clearance for accessibility and for combustion & ventilation air supply must be maintained at all times when the heater is operating.
  • Service and repair should be done by a qualified service person. The heater should be inspected before each use and at least annually by a qualified person. More frequent cleaning may be required as necessary. Do not service while hot or operating.
  • Never connect the heater to an unregulated gas supply.
  • The heater is shipped from the factory for LP(Propane) gas. This heater is for use with propane gas only, do not convert the heater to any other gas. Installation must conform to local codes or, in the absence of local codes, with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI/NFPA 58 and the Natural Gas and Propane Installation Code CSA B149.1
  • The minimum and maximum inlet pressures to the regulator from the gas tank are 5 psi and bottle pressure, respectively. Use only the regulator & hose assembly provided with the heater. Inspect the regulator/hose assembly prior to each use of the heater. If there is excessive abrasion or wear, or the hose is cut, replace it with the regulator/hose assembly listed on the parts list prior to using this heater.
  • Gas supply connections should be checked using a 50/50 solution of liquid dish soap and never use a flame to check for gas leaks.
  • The electrical connection & grounding must comply with National Electrical Code. ANSI/NFPA 70 or in Canada CSA C22.1, Canadian Electrical Code, Part 1. Use only a properly grounded three (3) prong receptacle.
  • Do not restrict inlet or outlet by any means. The flow of combustion and ventilation air is not to be obstructed.
  • This heater should not be directed toward any propane-gas container within 20 ft (6M). The heater must be located at least 6 ft. (1.83 m) in the U.S.; or (ii) 10 ft. (3 m) in Canada, from any propane gas container.
  • The propane cylinder supply system must be arranged to provide for vapor withdrawal from the operating cylinder.
  • This heater is not to be used with external thermostats, timers, or other devices that control or alter the electrical supply to the heater.

WARNING : Motor and fan must be running before lighting, during operation, and at shutdown, in order to prevent a flame-out condition that could result in personal injury or property damage.

PRODUCT FEATURES

  • Portable & Stable
  • Wind Resistant & Rain Protected
  • Continuous Spark Ignition or  Piezo Electric Spark Ignition
  • 100% Safety Shutoff System
  • Continuous Adjustable Input Ratings (Except FA40)

UNPACKING HEATER

  1. Remove the heater from the carton.
  2. Remove all protective packing applied to the heater for shipment.
  3. Retain cartons and packaging material until the unit is operated and found in good condition.
  4. Check the heater for any shipping damage. If the heater shows any external or internal damage, promptly inform the dealer/distributor where you purchased the heater.

Assembly Components and Instructions for Steel Base Units:

Tools required for assembly:
All Models: Adjustable Wrench
FA100 – FA150: Phillips Head Screw Driver| Contents:
All Models: Unit, Manual, Hose and Regulator Assembly
FA100 – FA150 Series Includes: 2 Cord Wrap Attachments, 4 Screws (ST3.5×10)| Assembly Time: 5 Minutes
---|---|---

1. Assembling the Cord Wrap Attachments: (FA100 – FA150 Series Only)

Parts Required:
4 Screws (ST3.5×10), and 2 Cord Wrap Attachments
Place the cord wrap attachment as shown, then use Phillips screwdriver to tighten the screws and secure the cord wrap attachments.

2. Regulator and Hose Connection: (All Models)

Dyna-Glo FA40DGP-01 Propane Construction Heater - Regulator and Hose
Connection

See figure on right. Connect the hose tightly to the heater using a wrench. Please also refer to page 8 in the manual.

Assembly Components and Instructions for Plastic Base Units:

Tools required for assembly: All Models: Adjustable Wrench FA125 Series: Phillips Head Screw Driver

Contents:
All Models: Unit, Manual, Hose and Regulator Assembly, Adjustable Leg, 2 Height Control Screws FA125 Series Includes: 2 Cord Wrap Attachments, 4 Screws (ST3.5×10)

Assembly Time : 5 Minutes

1. Assemble the Leg:

Dyna-Glo FA40DGP-01 Propane Construction Heater -Assemble the
Leg

2. Assemble the Height Control Screw:

Dyna-Glo FA40DGP-01 Propane Construction Heater -Height Control
Screw

Parts Required : Height Control Screw 2 pcs
Turn the Height Control Screw clockwise to lock it. Turn the Height Control Screw counterclockwise to unlock it.

3. Assembling the Cord Wrap Attachments:

Parts Required: 4 Screws (ST3.5X10) and 2 Cord Wrap Attachments
Place the cord wrap attachments as shown, then use a Phillips screwdriver to tighten the screws and secure the cord wrap attachments.

4. Regulator and Hose Connection:

Dyna-Glo FA40DGP-01 Propane Construction Heater -
Regulator

See figure on right.
Connect the hose tightly to the heater using a wrench.  Please also refer to page 8 in the manual.

*INFORMATION ON SIZE CAPACITY OF PROPANE GAS CYLINDERS:**

The chart below shows the number and size of propane tanks needed to run this heater.
*Less gas is vaporized at lower temperatures.
You may need two or more 100 pounds (45 kg) tanks or one larger tank in colder weather. (See the parts list for your model of heater to get the specified regulator assembly.)

Temperature (°F-°C) at tank Number of Tanks
40,000-60,000 BTU/h 100,000 -125,000 BTU/h

Above

32°F (0°C)

| 1 – 20lb (9kg)| 2 – 100lb (45kg)| 2 – 100lb (45kg)
32°F (0°C)| 1 – 20lb (9kg)| 2 – 100lb (45kg)| 2 – 100lb (45kg)
20°F (-7°C)| 1 – 20lb (9kg)| 2 – 100lb (45kg)| 3 – 100lb (45kg)
10°F (-12°C)| 1 – 20lb (9kg)| 3 – 100lb (45kg)| 3 – 100lb (45kg)
-10°F (-23°C)| 2 – 20lb (9kg)| Use Larger Tank| Use Larger Tank
-20°F (-29°C)| 1 – 100lb (45kg)| Use Larger Tank| Use Larger Tank

The propane (LP) gas tank must also be equipped with the following:

  • A collar to protect the Propane gas valve.
  • A shutoff valve terminating a Propane gas cylinder valve outlet as specified in the American National Standards for Compressed Gas Cylinder Valve  Outlets and Inlet Connections.
  • A safety relief valve having direct communications with the vapor space of the tank.
  • An arrangement of vapor withdrawal.

The propane (LP) gas pressure regulator and hose assembly supplied with this heater must be used without alteration.

The hose assembly shall be visually inspected prior to each use of the heater. If it is evident that there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation. The replacement hose assembly shall be that specified by the manufacturer.

INSTALLATION TO THE PROPANE GAS TANK

IMPORTANT : You must use a propane/LP gas supply cylinder that is compatible with the connection device provided with the hose and regulator.

  1. Provide propane/LP supply system. Ensure that the valve on the cylinder is fully closed by turning the knob fully clockwise ( ). Ensure that the cylinder is fully upright for vapor withdrawal. (see size/capacity, page 7).
  2. Connect a hose to heater inlet. Tighten firmly using a wrench. You must use the regulator supplied with the heater
  3. Connect fuel gas fitting hose/regulator assembly to propane LP tank(s). 3a. For units with a POL fitting (see figure 1) turn fuel fitting counterclockwise into threads on the tank. Tighten firmly using a wrench. Some models have a handwheel that can be used to tighten the fitting. This handwheel can be slid off of the nut so that a wrench can also be used to tighten the fitting. IMPORTANT: Position the regulator so that hose leaving the regulator is in a horizontal position. 3b. For units with a QCC fitting (see figure 2) turn QCC gas fitting clockwise onto threads on the tank. Tighten firmly using your hand (DO NOT USE A WRENCH). IMPORTANT: Position the regulator so that the regulator vent is pointing down toward the floor and the arrow on the regulator is visible.
  4. Open propane/LP supply valve on propane/LP tank(s) slowly. NOTE: If not opened slowly, the excess flow device in the regulator may stop gas flow. If this happens, close the propane/LP supply valve, wait one minute (or until you hear a click), and open again slowly.
  5. Check all connections for leaks. Apply a 50/50 solution of liquid dish soap and water to gas joints. Bubbles forming show a leak that must be corrected.
  6. Close propane / LP supply valve before attempting to repair the connection.

WARNING : Purging and filling of LP gas tanks must be performed by personnel who has been thoroughly trained in accepted LP gas industry procedures. Failure to follow these instructions may result in an explosion, fire, severe personal injury, or death.

REFILLING THE PROPANE GAS TANK

ALL NEW CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING.

  • Turn heater gas valve knob and gas tank valve to OFF position.

  • Propane tank valve equipped with the old style fitting has LEFT HANDED THREADS. Turn POL fitting
    CLOCKWISE to loosen. Protect POL fitting when disconnected from the tank. Have tank filled by your local Propane gas supplier.

  • Fasten full Propane tank and connect POL fitting to tank valve by turning COUNTERCLOCKWISE.

  • With heater gas valve knob still in the OFF position, turn ON tank valve and check for leaks with soap solution.

PROPANE SAFETY

Propane is safe to use when properly handled. Careless handling of the Propane gas tank could result in fire and/or an explosion. Therefore:

  • Always keep tank/cylinder securely fastened in an upright position.
  • Avoid tipping tank on its side when connected to a regulator since this may cause damage to diaphragm in regulator.
  • Handle valves with care.
  • Never connect an unregulated Propane tank to construction heater.
  • Do not subject Propane tank to excessive heat.
  • Tightly close the gas shutoff valve on the Propane tank after each use.
  • The POL fitting must be protected when disconnected from the propane tank.
  • Never store a Propane gas tank inside a building or in the vicinity of any gas burning appliance.
    THE DISCONNECTED TANK MUST NEVER BE STORED IN A BUILDING, GARAGE OR ANY OTHER ENCLOSED AREA.

LEAK CHECKING
Check all gas connections with a soap solution to be sure they are tight and leak proof.

  • The installation of your heater must meet all local codes and/or gas utility requirements or, in the absence of local codes, with the Storage and Handling of Liquefied Petroleum Gases, ANSI/ NFPA 58 and the Natural and Propane Installation Code, CSA B149.1.
  • The minimum clearances to combustible construction: Side – 24” (61 cm); Top – 36” (92 cm); Front – 72” (183 cm); Floor – combustible, must be maintained at all times.
  • The hose assembly should be visually inspected prior to each use of the heater. If it is evident that there is excessive abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation.
  • The replacement hose assembly shall be that specified by the manufacturer (Refer to parts list).

LIGHTING INSTRUCTIONS

WARNING : Motor and fan must be running before lighting, during operation and shutdown, in order to prevent a flame-out condition which could result in personal injury or property damage.
NOTE : This heater uses a continuous spark ignition system. This unit will continue to make a clicking/ ticking sound at all times before ignition, after ignition, and during operation, regardless of valve knob positioning.

  1.  Connect the power cord to a properly grounded three (3) prong 120V, 60Hz, single-phase receptacle.
  2. Turn gas valve knob clockwise to OFF position.
  3. Wait five (5) minutes to clear any gas. Then smell for gas, if you don’t smell gas, go to the next step.
  4. Turn gas supply ON by turning Propane tank valve counterclockwise .
  5. Push in and turn gas control knob counterclockwise   to “LOW/IGN”. This will light the burner. If needed, keep pressing the control knob until the burner lights and keep depressing and turning from OFF to LOW/IGN on Piezoelectric spark models. (“HIGH/IGN”: In case of FA40 series)
  6. Keep the valve knob depressed for at least 30 seconds after lighting the burner. After 30 seconds release the valve knob.
  7. If the burner does not stay lit, repeat the lighting procedure.
  8. When the burner is lit, turn gas valve knob counterclockwise   to the desired setting. (All models, except FA40 series).

SHUTDOWN INSTRUCTIONS

WARNING : Motor and fan must be running before lighting, during operation and at shutdown,in order to prevent a flame-out condition that could result in personal injury or property damage.
Turn gas valve knob clockwise to OFF position.
Turn gas supply OFF by turning Propane tank valve clockwise   to close.
Disconnect the power cord once the heater has cooled to ambient temperature.

TEST FIRING HEATER

Test fire your construction heater, following the lighting instructions applicable to the gas control system employed. Leak test all gas connections with a soap solution. Soap bubbles indicate gas leakage. DO NOT use a match or flame to test for gas leaks.

STORAGE

Never store a Propane gas tank inside a building or in the vicinity of any gas or oil-burning appliance. When the Propane tank is not disconnected from the construction heater, the gas tank and heater must be stored outdoors in a well-ventilated area, out of the reach of children. If for any reason the heater is to be stored indoors, the tank must be disconnected and stored outdoors in a well-ventilated area out of reach of children, in accordance with the standard for the Storage and Handling of Liquefied Petroleum Gases, ANSI / NFPA 58, and CSA B149.1, Natural Gas and Propane  Installation Code. The plastic tank valve plug supplied with your tank must be tightly installed when the tank is disconnected from the heater.

MAINTENANCE INSTRUCTIONS

  1. Turn the unit off, allow the heater to fully cool, and disconnect the propane hose before performing any Maintenance functions. Unplug the unit from the 120V receptacle.
  2. Keep the unit clean and keep the inside of the torpedo housing debris free.
  3. Have the unit checked by a qualified technician at least once a year, preferably prior to the heatin season.

REPLACEMENT PARTS

Warning: Use only original replacement parts. This Heater must use design- specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fatal injuries. This will also protect your warranty coverage for parts replaced under warranty. Parts warranty and non- warranty: Contact authorized dealers of this product. If they can not supply original replacement part(s), either contact your nearest Parts  Central or GHP Group Inc., Technical Service Department at 1-877-447-4768.

When calling GHP Group Inc., have ready:

  • your name
  • your address
  • how heater was malfunctioning
  • serial number of heater
  • model number of heater
  • replacement part number

TROUBLESHOOTING

PROBLEM| POSSIBLE CAUSE|

CORRECTIVE ACTION

---|---|---
1. Control dial is off and unit is clicking/ticking| 1. This heater uses a continuous spark ignition system. This unit will continue to make a clicking/ticking sound at all times before ignition, after ignition and during operation, regardless of valve knob positioning.| 1. No corrective action is needed.
2. The unit is ticking/clicking while the heater is lit.| 1. This heater uses a continuous spark ignition system. This unit will continue to make a clicking/ticking sound at all times before ignition, after ignition and during operation, regardless of valve knob positioning.| 1. No corrective action is needed.
3. Fan does not turn when electrical connection is made.

| 1. No electric power to heater.
2. Fan blade contacts inside of heater housing.
3. Fan blade(s) bent
4. Fan motor defective.| 1. Check current to an electric outlet. If voltage is correct, check the power cord and extension cord for
2. Be sure that housing is not damaged. Make sure there are no obstructions to the fan.
3. Straighten blade(s) to match others.
4. Replace motor.
4. Heater will not fire.| 1.    No spark at ignitor.
2.    Improper spark gap.
3.    Bad electrode.| 1Check ignitor wire. Re-­‐attach or tighten if loose. Check Spark module. Replace if necessary.
2Set gap (See specifications for gap).
3. Replace Spark Plug.
5. Heater quits while running.| 1. Internal temperature too high causing the limit switch to shut down the operation.
2. Damaged Control Valve.
3. Dust or debris build-­‐up inside of the heater.| 1. If the output of the heater is restricted, the internal temperature becomes too high. Move the heater away from any obstructions.
2. Replace Control Valve.
3. Clean the inside of the heater.

Always be sure to follow proper maintenance procedures, by cleaning the heater once per month during regular usage, and check spark gap at least once per season.

WIRING DIAGRAMS

PIEZO/MANUAL SPARK MODELS MANUELLE
MODELOS DE CHISPA MANUAL O PIEZOELCTRICA

WIRING DIAGRAMS

Dyna-Glo FA40DGP-01 Propane Construction Heater -WIRING DIAGRAMS
1

REPLACEMENT PARTS LIST

MODELS:
FA40 Series
FA50 Series
FA60 Series

REPLACEMENT PARTS LIST

__**ITEM No.** DESCRIPTION __**QTY** PART NUMBER
40 SERIES 50 SERIES 60 SERIES
1 INNER SHELL ASSEMBLY 1 2304818
2 NOZZLE 1 *2304829
3 FLAME CAP 1 2304819
4 THERMAL SWITCH BRACKET 1 2304826
5 THERMAL SWITCH 1 2201373
6 NOZZLE NUT 1 2304578
7 SPARK PLUG ASSEMBLY 1 2201375
8 THERMOCOUPLE ASSEMBLY (1130/1474-­‐425L) 1 2304885
9 GAS TUBING ASSEMBLY 1 2304830
__ 10 OUTER SHELL -­‐ ORANGE 1 2305403
OUTER SHELL -­‐ BLACK 1 2315915 2315915
OUTER SHELL -­‐ GRAY 1 2315956 2315956
OUTER SHELL -­‐ BLUE 1 2315312 2315312
11 CORD WRAP (select models only) 2 N/A
12 HANDLE ASSEMBLY -­‐ BLACK 1 2101447
HANDLE ASSEMBLY -­‐ GRAY 1 2305426 2305426
12.1 SCREW -­‐ HANDLE FRONT 1 2001355
12.2 SCREW -­‐ HANDLE FRONT 1 2001077
12.3 NUT -­‐ HANDLE REAR 1 2000384
13 MOTOR SUPPORT 1 2304823
13.1 MOTOR -­‐ MOUNTING BOLT 2 2001332
13.2 SLEEVE 1 2304949
14 MOTOR ASSEMBLY 1 2305909
14.1 MOTOR -­‐ FAN 1 2304821
15 FAN GUARD -­‐ BLACK 1 2304828
FAN GUARD -­‐ GRAY 1 2305411 2305411
16 MOTOR BRACKET 1 2304937
17 VALVE -­‐ GAS 1 GS22 (FA40)
18 PRESSURE SWITCH 1 N/A
19 VALVE BRACKET 1 2304624
20 BASE ASSEMBLY -­‐ BLACK 1 2304923
BASE ASSEMBLY -­‐ GREY 1 2305405 2305405
21 POWER CORD ASSEMBLY 1 2201368
22 GAS CONNECTOR INLET 1 2304831
23 CAPACITOR 1 2201372
24 BASE LOWER -­‐BLACK 1 2304925
BASE LOWER -­‐ GREY 1 2305407 2305407
25 KNOB GAS VALVE -­‐ BLACK 1 2101451
KNOB GAS VALVE -­‐ ORANGE 1 2305466 2305466
26 HEIGHT CONTROLLER -­‐ BLACK 1 2304927
HEIGHT CONTROLLER -­‐ GREY 1 2305409 2305409
27 HEIGHT CONTROL SCREW -­‐ BLACK 1 2304510
HEIGHT CONTROL SCREW -­‐ ORANGE 1 2305467 2305467
28 LEAD WIRE ASSEMBLY 1 2201371
29 SPARK MODULE 1 N/A
30 PCB ASSEMBLY 1 2201369

__

__

31

| REG & HOSE ASSEMBLY -­‐ 10FT (3M)| 1| KR-­‐106-­‐01(POL-­‐3000)| KR-­‐106-­‐01(POL-­‐3000)| KR-­‐106-­‐01(POL-­‐3000)
REG & HOSE ASSEMBLY -­‐ 10FT (3M) w/HANDWHEEL| 1| KR-­‐106-­‐01(HW-­‐3000)| KR-­‐106-­‐01(HW-­‐3000)| KR-­‐106-­‐01(HW-­‐3000)
REG & HOSE ASSEMBLY (QCC) -­‐ 10FT (3M)| 1| TYQ-­‐9C-­‐3000| TYQ-­‐10C-­‐3000| TYQ-­‐10C-­‐3000
REG & HOSE ASSEMBLY -­‐15FT (4.6M)| 1| KR-­‐106-­‐01(POL-­‐4600)| KR-­‐106-­‐01(POL-­‐4600)| KR-­‐106-­‐01(POL-­‐4600)
REG & HOSE ASSEMBLY -­‐15FT (4.6M) w/HAND WHEEL| 1| KR-­‐106-­‐01(HW-­‐4600)| KR-­‐106-­‐01(HW-­‐4600)| KR-­‐106-­‐01(HW-­‐4600)
REG & HOSE ASSEMBLY (QCC) -­‐ 15FT (4.6M)| 1| TYQ-­‐9C-­‐4572| TYQ-­‐10C-­‐4572| TYQ-­‐10C-­‐4572

  • VERSION NOT SHOWN IN EXPLODED VIEW

PROPANE CONSTRUCTION HEATER ILLUSTRATED / PARTS BREAKDOWN

Dyna-Glo FA40DGP-01 Propane Construction Heater -PROPANE CONSTRUCTION
HEATER

REPLACEMENT PARTS LIST

__**ITEM**

No.

| __**DESCRIPTION| **QTY| PART NUMBER
---|---|---|---
100 SERIES| 125 SERIES| 150 SERIES
1| INNER SHELL ASSEMBLY| 1| 2304929| 2304929| 2304929
2| NOZZLE| 1| *2304943| 5030077| 2304944
3| FLAME CAP| 1| 2304930| 2325122| 2304931
4| THERMAL SWITCH BRACKET| 1| 2304826| 2315515| 2001355
5| THERMAL SWITCH| 1| 2201373| 2201373| 2201373
6| NOZZLE NUT| 1| 2304578| 2304945| 2304945
7| SPARK PLUG ASSEMBLY| 1| 2201392| 2206034| 2201393
8| THERMOCOUPLE ASSEMBLY (1130/1474-­‐425L)| 1| 2304885| 2304885| 2304885
9| GAS TUBING ASSEMBLY| 1| 2304946| 2325138| 2304947
**
**

10

| OUTER SHELL -­‐ ORANGE| 1| N/A| 2305971| N/A
OUTER SHELL -­‐ BLACK| 1| N/A| N/A| N/A
OUTER SHELL -­‐ GRAY| 1| 2315916| 2315916| 2315916
OUTER SHELL -­‐ BLUE| 1| N/A| N/A| N/A
11| CORD WRAP (select models only)| 2| 2101423| 2101423| 2101423
12| HANDLE ASSEMBLY -­‐ BLACK| 1| 2101447| 2101447| 2101447
HANDLE ASSEMBLY -­‐ GRAY| 1| 2305426| 2305426| 2305426
12.1| SCREW -­‐ HANDLE FRONT| 1| 2001355| 2001355| 2001355
12.2| SCREW -­‐ HANDLE FRONT| 1| 2001077| 2001077| 2001077
12.3| NUT -­‐ HANDLE REAR| 1| 2000384| 2000384| 2000384
13| MOTOR SUPPORT| 1| 2304823| 2304823| 2304823
13.1| MOTOR -­‐ MOUNTING BOLT| 2| 2001332| 2001332| 2001332
13.2| SLEEVE| 1| 2304949| 2304949| 2304949
14| MOTOR ASSEMBLY| 1| 2304548| 2304548| 2304548
14.1| MOTOR -­‐ FAN| 1| 2304936| 2304936| 2304936
15| FAN GUARD -­‐ BLACK| 1| 2304939| 2304939| 2304939
FAN GUARD -­‐ GRAY| 1| 2305412| 2305412| 2305412
16| MOTOR BRACKET| 1| 2304938| 2304938| 2304938
17| VALVE -­‐ GAS| 1| GS22A(FA125)| GS22A(FA125)| GS22A(FA150)
18| PRESSURE SWITCH| 1| 2305976| 2305976| 2305976
19| VALVE BRACKET| 1| 2304624| 2304624| 2304624
20| BASE ASSEMBLY -­‐ BLACK| 1| 2304924| 2304924| 2304924
BASE ASSEMBLY -­‐ GREY| 1| N/A| 2403354| N/A
21| POWER CORD ASSEMBLY| 1| 2101673| 2101673| 2101673
22| GAS CONNECTOR INLET| 1| 2304831| 2304831| 2304831
23| CAPACITOR| 1| 2301390| 2301390| 2301390
24| BASE LOWER -­‐ BLACK| 1| 2304926| 2304926| 2304926
BASE LOWER -­‐ GREY| 1| N/A| 2403355| N/A
25| KNOB GAS VALVE -­‐ BLACK| 1| 2101451| 2101451| 2101451
KNOB GAS VALVE -­‐ ORANGE| 1| N/A| 2305466| N/A
26| HEIGHT CONTROLLER -­‐ BLACK| 1| 2304928| 2304928| 2304928
HEIGHT CONTROLLER -­‐ GREY| 1| N/A| 2403356| N/A
27| HEIGHT CONTROL SCREW -­‐ BLACK| 1| 2304510| 2304510| 2304510
HEIGHT CONTROL SCREW -­‐ ORANGE| 1| N/A| 2305467| N/A
28| LEAD WIRE ASSEMBLY| 1| 2201371| 2201371| 2201371
29| SPARK MODULE| 1| 2201391| 2201391| 2201391
30| PCB ASSEMBLY| 1| 2201369| 2201369| 2201369
__

__

31

| REG & HOSE ASSEMBLY -­‐ 10FT (3M)| 1| GR-­‐109(POL-­‐3000)| GR-­‐109(POL-­‐3000)| GR-­‐109(POL-­‐3000)
REG & HOSE ASSEMBLY -­‐ 10FT (3M) w/HANDWHEEL| 1| GR-­‐109(HW-­‐3000)| GR-­‐109(HW-­‐3000)| GR-­‐109(HW-­‐3000)
REG & HOSE ASSEMBLY(QCC) -­‐ 10FT (3M)| 1| TYQ-­‐6D1-­‐3000| TYQ-­‐6D1-­‐3000| TYQ-­‐6E1-­‐3000
REG & HOSE ASSEMBLY -­‐15FT (4.6M)| 1| GR-­‐109(POL-­‐4600)| GR-­‐109(POL-­‐4600)| GR-­‐109(POL-­‐4600)
REG & HOSE ASSEMBLY -­‐15FT (4.6M) w/HAND WHEEL| 1| GR-­‐109(HW-­‐4600)| GR-­‐109(HW-­‐4600)| GR-­‐109(HW-­‐4600)
REG & HOSE ASSEMBLY(QCC) -­‐15FT (4.6M)| 1| TYQ-­‐6D1-­‐4572| TYQ-­‐6D1-­‐4572| TYQ-­‐6E1-­‐4572

  •  VERSION  NOT  SHOWN  IN  EXPLODED  VIEW

PROPANE CONSTRUCTION HEATER ILLUSTRATED / PARTS BREAKDOWN

MODELS: RMC-FA100/DGP/DGP-01
RMC-FA125/DGP/DGP-01
LPFA125DGDDyna-Glo FA40DGP-01 Propane Construction Heater -PROPANE
CONSTRUCTION HEATER 2

REPLACEMENT PARTS LIST

__**ITEM**

No.

| DESCRIPTION| __**QTY| PART NUMBER
---|---|---|---
FA100DGP| FA125DGP| LPFA125DGD*
1| INNER SHELL ASSEMBLY| 1| 2304929| 2304929| 2304929
2| NOZZLE| 1|
2304943| 5030077| 5030077
3| FLAME CAP| 1| 2304930| 2325122| 2325122
4| THERMAL SWITCH BRACKET| 1| 2304826| 2315515| 2315515
5| THERMAL SWITCH| 1| 2201373| 2201373| 2201373
6| NOZZLE NUT| 1| 2304578| 2304945| 2304945
7| SPARK PLUG ASSEMBLY| 1| 2201392| 2206034| 2206034
8| THERMOCOUPLE ASSEMBLY (1130/1474-­‐425L)| 1| 2304885| 2304885| 2304885
9| GAS TUBING ASSEMBLY| 1| 2305975| 2325137| 2325137
10| OUTER SHELL -­‐ ORANGE| 1| 2305971| 2305971| N/A
OUTER SHELL -­‐ BLACK| 1| N/A| N/A| 2403443
11| CORD WRAP| 2| 2101423| 2101423| 2101423
12| MOTOR SUPPORT| 1| 2304823| 2304823| 2304823
12.1| MOTOR -­‐ MOUNTING BOLT| 2| 2001332| 2001332| 2001332
12.2| SLEEVE| 1| 2304949| 2304949| 2304949
13| MOTOR ASSEMBLY| 1| 2304548| 2304548| 2304548
13.1| MOTOR -­‐ FAN| 1| 2304936| 2304936| 2304936
14| FAN GUARD -­‐ GRAY| 1| 2305412| 2305412| N/A
FAN GUARD -­‐ BLACK| 1| N/A| N/A| 2304939
15| MOTOR BRACKET| 1| 2304938| 2304938| 2304938
16| BASE RIGHT SIDE| 1| 2306000| 2306000| 2306000
17| LEG HOLDER| 2| 2315002| 2315002| 2315002
18| CAPACITOR| 1| 2301390| 2301390| 2301390
19| PRESSURE SWITCH| 1| 2305976| 2305976| 2305976
20| POWER CORD ASSEMBLY| 1| 2101673| 2101673| 2101673
21| GAS CONNECTOR INLET| 1| 2304831| 2304831| 2304831
22| BASE BOTTOM| 1| 2315001| 2315001| 2315001
23| VALVE BRACKET| 1| 2305973| 2305973| 2305973
24| VALVE -­‐ GAS| 1| GS22A(FA125)| GS22A(FA125)| GS22A(FA125)
25| BASE LEFT SIDE| 1| 2305999| 2305999| 2305999
26| KNOB GAS VALVE -­‐ ORANGE| 1| 2101588| 2101588| N/A
KNOB GAS VALVE -­‐ BLACK| 1| N/A| N/A| 2101451
27| HEIGHT CONTROL SCREW -­‐ ORANGE| 2| 2315003| 2315003| N/A
HEIGHT CONTROL SCREW -­‐ BLACK| 2| NA| NA| 2403444
__

28

| REGULATOR & HOSE ASSEMBLY -­‐ 10FT (3M)| 1| GR-109(POL-3000)| GR-109(POL-3000)| GR-109(POL-3000)
REGULATOR & HOSE ASSEMBLY(QCC) -­‐ 10FT (3M)| 1| N/A| N/A| TYQ-­‐6D1-­‐3000
REGULATOR & HOSE ASSEMBLY -­‐15FT (4.6M)| 1| GR-109(POL-4600)| GR-109(POL-4600)| GR-109(POL-4600)
REGULATOR & HOSE ASSEMBLY(QCC) -­‐15FT (4.6M)| 1| N/A| N/A| TYQ-­‐6D1-­‐4572
29| LEG| 1| 2305972| 2305972| 2305972
30| LEAD WIRE ASSEMBLY| 1| 2201371| 2201371| 2201371
31| SPARK MODULE| 1| 2201391| 2201391| 2201391
32| PCB ASSEMBLY| 1| 2201369| 2201369| 2201369

  •  VERSION  NOT  SHOWN  IN  EXPLODED  VIEW

WARRANTY

LIMITED WARRANTY:
This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at its option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group,  Inc., within one (1) year of retail purchase. (Shipping costs, labor costs, etc. are the responsibility of the purchaser.)

DUTIES OF THE OWNER:
This heating appliance must be operated in accordance with the written instructions furnished with this heater. This warranty shall not excuse the owner from properly maintaining this heater in accordance with the written instructions furnished with this heater. A bill of sale, canceled check or payment record must be kept to verify the purchase date and establish a warranty period. Original carton should be kept in case of warranty return of the unit.

WHAT IS NOT COVERED:

  1. Damage resulting from use of improper fuel.
  2. Damage caused by misuse or use contrary to the owners manual and safety guidelines.
  3. Damage caused by a lack of normal maintenance.
  4. Fuses
  5. Use of non-standard parts or accessories.
  6. Damage caused in transit. Freight charges on warranty parts or heaters to and from the factory shall be the responsibility of the owner.

This warranty does not imply or assume any responsibility for consequential damages that may result from t he uses, misuse, or lack of routine maintenance of this heating appliance. A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of maintenance. This warranty does not cover claims which do not involve defective workmanship or materials. FAILURE TO PERFORM GENERAL MAINTENANCE (INCLUDING CLEANING) WILL VOID THIS WARRANTY.

THIS LIMITED WARRANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE. THE REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES. IN NO EVENT WILL GHP GROUP, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you.

CLAIMS HANDLED AS FOLLOWS:

  1. Contact your retailer and explain the problem.
  2. If the retailer is unable to resolve the problem, contact our Customer Service Dept. detailing the heater model, the problem, and proof of date of purchase.
  3. A representative will contact you. DO NOT RETURN THE HEATER TO GHP GROUP,INC. unless instructed by our Representative. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

TO REGISTER THE WARRANTY ON YOUR HEATER, PLEASE FILL OUT THIS CARD COMPLETELY AND MAIL WITHIN 14 DAYS FROM DATE OF PURCHASE OR REGISTER ON-LINE AT www.ghpgroupinc.com

NAME: __ PHONE: (          ) __ EMAIL: ____
ADDRESS: _ CITY: __ STATE: __ ZIP: ____
MODEL: ____ SERIAL #: ___
DATE PURCHASED: __
DEALER PURCHASED FROM: ____ TYPE OF STORE: __
CITY & STATE WHERE PURCHASED: __ PRICE PAID: ___

Please Take a Minute To Give Us Your Answers To The Following Questions.
All Responses Are Used Solely For Market Research And Are Held In Strict Confidence.

Who primarily decided this purchase? □ Male   □ Female □  18-24   □ 25-39   □ 40-59   □ 60 and over
Purpose of Purchase?


Do you own any other portable heaters? □ Yes  □ No If yes, type____brand_
How do you intend to use your new heater? □ Construction Site  □ Farm □Warehouse/Commercial  □ Garage/Outbuilding  □ Other
How did you  become aware of this heater? □ In-Store Display  □ Newspaper Ad □ Magazine Ad □ Friend/Relative
□  TV Commercial □ Store Salesperson  □ Other  ___
What made you select this heater? □ Style □ Size/Portability
□ Price  □ Package  □ Brand  □ Other ___   Do you: □ own □ rent Would you recommend this heater to a friend? □  Yes □ No Please give us your comments:____

THANK YOU FOR COMPLETING THIS FORM!
Information will be held confidential.

WARRANTY REGISTRATION
IMPORTANT : We urge you to fill out your warranty registration card within fourteen (14) days of date of purchase. You can also register your warranty on the internet at www.ghpgroupinc.com. Complete the entire serial number. Retain this portion of the card for your records.

GHP Group, Inc. 6440 W Howard St
Niles, IL 60714-3302 Tel: 877-447-4768
www.ghpgroupinc.com

SAVE THIS CARD!

Place Postage Stamp Here

GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302

Documents / Resources

| Dyna-Glo FA40DGP-01 Propane Construction Heater [pdf] Owner's Manual
PROPANE CONSTRUCTION HEATER, FA40DGP-01, RMC-FA50DGD, RMC-FA60DGD, RMC- FA100DGD, RMC-FA125DGD, LPFA125DGD, RMC-FA150DGD, RMC-FA40, DGP, DGP-01, RMC- FA50, DGP, DGP-01, RMC-FA60, DGP, DGP-01, RMC-FA100, DGP, DGP-01
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Dyna-Glo User Manuals

Related Manuals