TRANE GEVG Water Source Heat Pump User Guide
- June 3, 2024
- Trane
Table of Contents
Quick Reference Guide
Water Source Heat Pump Axiom™
Vertical — Standard Efficiency 0.5 to 5 Tons
GEVG
GEVG Water Source Heat Pump
Table 1.List of options
Factory Installed Options | Field Installed Options |
---|---|
1-inch or 2-inch Ducted Filter Rack | 2-inch or 4-inch Ducted Filter Rack |
Air-Fi® Wireless Communications | Ducted Panel |
Deluxe 24V, UC400B or ZN524 Controls | Hose Kits (or ship separate hoses and |
valves)
Factory-mounted Isolation Valve| Pump Module
Hot Gas Reheat| Pump Module Hose Kit
Low, Medium and High Electric Heat| Thermostats or Zone Sensors
Matte or Foil Face Insulation| Waterside Economizer
MERV 8 or 13 Filters|
Polymer or Stainless Steel IAQ Drain Pan
Recessed Unit Mounted Disconnect Switch
Standard or Deluxe Sound Package
Table 2.General data – models GEVG006-024
Model GEVG | 006 | 009 | 012 | 015 | 018 | 024 |
---|---|---|---|---|---|---|
Unit Size width x depth x height (in.) | 19 x 19 x 30 | 19 x 19 x 30 | 19 x 19 x | |||
30 | 21.5 x 21.5 x 34 | 21.5 x 21.5 x 34 | 21.5 x 23 x 36 | |||
Compressor type | Rotary | Rotary | Rotary | Rotary | Rotary | Scroll |
Net weight (lbs.) | 149 | 149 | 149 | 155 | 157 | 210 |
Ship weight (lbs.) | 201 | 201 | 201 | 210 | 212 | 268 |
Filter size nominal (in.) | 14 x 16 | 14 x 16 | 14 x 16 | 16 x 19 | 16 x 19 | 16 x |
19
Water in/out size (FPT)| 0.5| 0.5| 0.5| 0.5| 0.5| 0.75
Condensate size (NPTI)| 0.75| 0.75| 0.75| 0.75| 0.75| 0.75
Blower wheel Size (in.)| 9 x 6| 9 x 6| 9 x 6| 9 x 8| 9 x 8| 10 x 8
Table 3.General data – models GEVG030-060
Model GEVG | 030 | 036 | 042 | 048 | 060 |
---|---|---|---|---|---|
Unit Size width x depth x height (in.) | 21.5 x 23 x 36 | 21.5 x 26 x 38 | 21.5 x | ||
26 x 38 | 24 x 32.5 x 42 | 24 x 32.5 x 42 | |||
Compressor type | Scroll | Scroll | Scroll | Scroll | Scroll |
Net weight (lbs.) | 214 | 220 | 252 | 280 | 285 |
Ship weight (lbs.) | 272 | 280 | 312 | 343 | 348 |
Filter size nominal (in.) | 16 x 19 | 18 x 23 | 18 x 23 | 20 x 30 | 20 x 30 |
Water in/out size (FPT) | 0.75 | 0.75 | 0.75 | 1.00 | 1.00 |
Condensate size (NPTI) | 0.75 | 0.75 | 0.75 | 0.75 | 0.75 |
Blower wheel Size (in.) | 10 x 8 | 10 x 9 | 10 x 9 | 11 x 11 | 11 x 11 |
Table 4.ANSI/AHRI/ASHRAE/ISO13256-1 WLHP, GWHP and GLHP performance – 0.5 to 5 Tons
Model| Rated GPM| Rated CFM| Water Loop Heat Pump|
Ground Water Heat Pump| Ground Loop Heat Pump
---|---|---|---|---|---
Cooling 86°F| Heating 68°F| Cooling 59°F| Heating 50°F|
Full Cool 77°F| Full Heat 32°F
Capacity Btuh|
EER
| Capacity Btuh|
COP
| Capacity Btuh|
EER
| Capacity Btuh|
COP
| Capacity Btuh|
EER
| Capacity Btuh|
COP
GEVG006| 1.50| 190| 7000| 13.7| 9300| 4.70| 8100| 21.30| 7500| 4.10| 7400|
16.00| 5600| 3.30
GEVG009| 2.25| 285| 8700| 15.5| 11200| 5.50| 9600| 23.80| 9100| 4.70| 8900|
17.80| 6700| 3.70
GEVG012| 3.00| 380| 11400| 14.9| 15300| 5.30| 13300| 24.20| 12400| 4.60|
12100| 17.60| 9400| 3.70
GEVG015| 3.75| 475| 15400| 15.4| 19300| 5.20| 17300| 23.60| 15700| 4.40|
16100| 17.90| 12400| 3.70
GEVG018| 4.50| 570| 18000| 15.7| 22800| 5.10| 20100| 24.20| 18700| 4.50|
18800| 18.20| 14400| 3.70
GEVG024| 6.00| 760| 23900| 16.1| 31100| 5.30| 26600| 24.40| 25300| 4.60|
24800| 18.50| 19600| 3.80
GEVG030| 7.50| 950| 29000| 15.4| 37900| 5.10| 32300| 23.00| 30800| 4.50|
30200| 17.70| 23300| 3.70
GEVG036| 9.00| 1140| 36000| 15.4| 45100| 5.00| 39900| 22.60| 36900| 4.40|
37300| 17.60| 28700| 3.60
GEVG042| 10.50| 1330| 40900| 14.9| 55600| 4.70| 45500| 22.00| 45600| 4.20|
42600| 17.10| 35300| 3.50
GEVG048| 12.00| 1520| 49500| 15.1| 62600| 4.90| 55700| 22.80| 50000| 4.20|
51800| 17.40| 37600| 3.30
GEVG060| 15.00| 1900| 55200| 14.5| 75400| 4.60| 61700| 21.30| 61200| 4.10|
57300| 16.50| 47000| 3.50
Notes:
- Rated in accordance with ANSI/AHRI/ASHRAE/ISO13256-1. Certified conditions are 80.6°F DB/66.2°F WB EAT in cooling and 68F DB/59°F WB EAT in heating.
- Models with capacities greater than 135,000 Btuh are not included in the ANSI/AHRI/ASHRAE/ISO13256-1 water-to-air and brine-to-air heat pump certification program.
Table 5.Electrical data – ECM motors – 0.5 to 5 tons GEVG
Model No.| Unit Volts| Blower Motor HP| Minimum
Circuit Ampacity| Maximum Overcurrent Protective Device
---|---|---|---|---
GEVG006| 208-230/60/1| 1/3| 5/5| 15/15
GEVG006| 265/60/1| 1/3| 5| 15
GEVG009| 208-230/60/1| 1/3| 6/6| 15/15
GEVG009| 265/60/1| 1/3| 5| 15
GEVG012| 208-230/60/1| 1/3| 9/9| 15/15
GEVG012| 265/60/1| 1/3| 7| 15
GEVG015| 208-230/60/1| 1/3| 10/10| 15/15
GEVG015| 265/60/1| 1/3| 7| 15
GEVG018| 208-230/60/1| 1/3| 12/12| 20/20
GEVG018| 265/60/1| 1/3| 10| 15
GEVG024| 208-230/60/1| 1/2| 19/19| 30/30
GEVG024| 265/60/1| 1/2| 13| 20
GEVG024| 208-230/60/3| 1/2| 11/11| 15/15
GEVG024| 460/60/3| 1/2| 6| 15
GEVG030| 208-230/60/1| 3/4| 20/20| 30/30
GEVG030| 208-230/60/3| 3/4| 13/13| 20/20
GEVG030| 265/60/1| 3/4| 16| 25
Table 5.Electrical data – ECM motors – 0.5 to 5 tons GEVG (continued)
Model No.| Unit Volts| Blower Motor HP| Minimum
Circuit Ampacity| Maximum Overcurrent Protective Device
---|---|---|---|---
GEVG030| 460/60/3| 3/4| 7| 15
GEVG036| 208-230/60/1| 3/4| 24/24| 40/40
GEVG036| 265/60/1| 3/4| 20| 30
GEVG036| 208-230/60/3| 3/4| 16/16| 25/25
GEVG036| 460/60/3| 3/4| 9| 15
GEVG042| 208-230/60/1| 3/4| 26/26| 40/40
GEVG042| 208-230/60/3| 3/4| 21/21| 30/30
GEVG042| 460/60/3| 1| 10| 15
GEVG048| 208-230/60/1| 1| 31/31| 50/50
GEVG048| 208-230/60/3| 1| 23/23| 35/35
GEVG048| 460/60/3| 1| 10| 15
GEVG060| 208-230/60/1| 1| 38/38| 60/60
GEVG060| 208-230/60/3| 1| 25/25| 40/40
GEVG060| 460/60/3| 1| 13| 20
Figure 1.Clearance – GEVG 0.5 to 5 Tons
A 24-inch clearance from other mechanical and electrical equipment (where
shown) is recommended for most unit configurations. This will enable panel
removal from the unit for service/maintenance.
The 24-inch side clearance on GEVG 0.5-5T models is for optimal access only.
Side clearance is not a requirement as most components can be accessed from
the front of the unit.
A 1-inch minimum clearance between the filter rack and any obstacle is
required for units in a free return application to provide proper air flow to
the air-to-refrigerant coil. A 12-inch minimum clearance between the filter
rack and any obstacle should be provided to properly attached ductwork.
The 1-inch dimension shown in the back of the unit represents the supply duct
collar for the back supply option. This clearance is needed to clear these
flanges.
Figure 2.Left return and right return/top supply (GEVG)
Table 6.Dimensional data left return and right return/top supply (GEVG)
Unit| Cabinet| Duct Collar| Duct Collar Location|
Blower Opening| Hi Volt| Nominal Filter Size| W.I. NPTI|
W.O. NPTI| Drain NPTI
---|---|---|---|---|---|---|---|---|---
Width| Depth| Height
A| B| C| D| E| F| G| H| J| K
006-012| 19.0| 19.0| 30.00| 11.38| 3.70| 1.40| 3.50| 8.00| 7.70| 12.25| 14 x
16| 1/2| 1/2| 3/4
015-018| 21.5| 21.5| 34.00| 13.25| 4.00| 1.00| 3.50| 10.50| 9.60| 14.25| 16 x
19| 1/2| 1/2| 3/4
024-030| 21.5| 23.0| 36.00| 13.25| 4.75| 0.63| 3.50| 10.50| 11.30| 15.25| 17 x
20| 3/4| 3/4| 3/4
036-042| 21.5| 26.0| 38.00| 13.25| 6.25| 0.63| 3.50| 11.80| 11.30| 16.25| 18 x
23| 3/4| 3/4| 3/4
048-060| 24.0| 32.5| 42.00| 17.75| 7.25| 0.75| 3.50| 13.70| 13.50| 18.25| 20 x
30| 1| 1| 3/4
Note: Units in a free return application will require more than 1-inch
clearance to provide proper air flow to the unit’s air-to-refrigerant coil.
Trane – by Trane Technologies (NYSE: TT), a global climate innovator – creates
comfortable, energy efficient indoor environments for commercial and
residential applications. For more information, please visit trane.com or
tranetechnologies.com.
Trane has a policy of continuous product and product data improvement and
reserves the right to change design and specifications without notice. We are
committed to using environmentally conscious print practices.
WSHP-PRC029B-EN 01 Oct 2021
Supersedes WSHP-PRC029A-EN (Jul 2021)
©2021 Trane