ARDEX TLTTM Building Panels can be installed over wood and metal studded walls horizontally or vertically by using the galvanized ARDEX TLTTM Screws & Washers. All vertical joints must be supported by suitable, load-bearing framing. Maximum spacing of studs is 16″ on center.

**STEP 1**
Place ARDEX TLTTM Screws and Washers 12″ apart vertically and 16″ apart horizontally. It is best when applying the screws to create a slight depression in the board to reduce any buildup at the screw. Vertical seams must be staggered.

**STEP 2**
Seam Waterproofing – Method 1 (ARDEX TLTTM Seam Tape)
Cover all seams and screw/washer dents with the recommended ARDEX modified thin-set mortar and ARDEX TLT Seam Tape. Make sure all seams and screws/washers are fully covered with a minimum 2″ overlap (approximately a 4.5″ patch to cover washers). Use a grout float to remove any excess thin-set and air pockets.

Seam Waterproofing – Method 2 (ARDEX CA 20 PTM)
Cover all seams and screw/washer dents with ARDEX CA 20 PTM. Flatten the excess adhesive with a spackle knife. Make sure all seams are fully covered for a watertight seal.

For Steam Showers – Method 3 (ARDEX TLTTM Waterproofing Membrane)
ARDEX requires a layer of TLT Waterproofing Membrane to be installed over the TLT Building Panels.