SUPERVAC V20-GB Ventilator User Guide
- June 3, 2024
- SUPERVAC
Table of Contents
- SUPERVAC V20-GB Ventilator
- Danger
- Breakage or Damage During Shipment
- General Description and Specifications
- Operation
- Starting the Engine
- Maintenance and Repair
- Troubleshooting
- Warranty
- Contact Information
- Parts List
- Exploded View
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SUPERVAC V20-GB Ventilator
Danger
PERSONAL RESPONSIBILITY CODE
The member companies of FEMSA that provide emergency response equipment and
services want responders to know and understand the tollowing
- Firefighting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times.
- It is your responsbility to read and understand any User’s instructions, including purpose and limitations, provided with any piece of equipment you may be called upon TO USe.
- It is your responsibility to know that you have been properly trained in Firefighting and/or Emergency Response and in the use, precautions, and care of any equipment you may be called upon to use.
- It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to use.
- It is your responsibility to know that your equipment is in operable condition and has been maintained in accordance with the manufacturer’s instructions.
- Failure to follow these guidelines may result in death, burns or other severe injury.
Breakage or Damage During Shipment
The transportation company is fully responsible for all shipping damage and
will resolve problems promptly if you handle it correctly. Please read these
instructions carefully.
Examine the contents of all shipping cases. If you find any damage, call your
transportation agent at once and have them make a description on the freight
or express bill describing the damage and the number of pieces. Then write us
and we will send you the original bill of lading. Get a claim blank from the
express or truck company. Fill the claim form out. Attach the claim blank to
the original bill of lading together with a copy of our invoice. Attach a memo
on which you show the value of the damaged goods. Mail or hand these papers to
your local transportation agent. They will process your claim with reasonable
promptness.
Please note, we cannot and will not enter claims for damages. If we filed
claim here, it would be sent to your local freight agent for verification and
investigation. This time can be saved by your filing the claim directly. Every
consignee is on the ground floor and in contact with the local agent who
inspects the damaged goods, and thus, each claim can be given individual
attention.
Since our goods are packed to comply with the regulations of all railroad,
truck, and express companies, we cannot allow deduction from any invoice
because of any damage, however, be sure to file your claim promptly. Our goods
are sold F.O.B. factory. We take receipt from the transportation company
certifying that the goods were delivered to them in good order, and our
responsibility ceases.
It is seldom that any breakage or damage occurs in any of our shipments, and
in no case will the customer be out any expense if they follow the above
instructions.
Be sure to keep all damaged goods subject to examination of the truck or
express company inspector, who may call on you some time later. These damaged
goods, of course, will belong to them, and they will inform you what to do
with them. If you dispose of these damaged goods, your claim may not be paid.
General Description and Specifications
Super Vac ventilators are specifically designed to provide a convenient and
portable source of air. Super Vac positive pressure ventilators are tested to
AMCA PPV Standard 240-95, for use in extreme conditions.
This ventilator is designed for high powered air movement. Super Vac’s
propeller produces a greater intake of air and eliminates turbulence at the
tips. Each blade is dynamically balanced for high efficiency and long life.
This document is designed to function as a quick start guide and not an in-
depth comprehensive instructional manual. Please read all accompanying
documents shipped with your ventilator. Due to the many features of gasoline
powered equipment thorough familiarity with the engine operating controls is
essential to assure safe and trouble free operation.
Product Safety Precautions
- Do not use the ventilator for purposes other than its’ intended use.
- Wear eye and ear protection when operating the ventilator.
- Never operate ventilator while fatigued.
- Do not disassemble or modify the ventilator in any way. Doing so may lead to mechanical failure or personal injury.
- Do not wear loose clothing that could become entangled in the operating ventilator.
- Never permit anyone to operate ventilator without proper instruction.
- Do not operate ventilator without proper inlet or outlet guards in place. If guards are missing or damaged, contact factory for replacements.
- Do not place fingers or other foreign objects through inlet or outlet guards. Should a foreign object enter the ventilator, immediately stop engine. Be certain all mechanical motion has stopped. Disconnect spark plug wire from spark plug and keep it away from spark plug before removing foreign object.
- Do not use with any fuel supply source other than the provided fuel tank.
- Engine exhaust gas contains poisonous carbon monoxide. Avoid inhalation of exhaust gas. Never run the engine in a closed or confined area.
- Do not place or operate ventilator on unsteady tables, slanted surfaces or other unstable surfaces. Never use this ventilator in any explosive environment.
- Do not use chock blocks to increase the angle of the ventilator, severe injury could occur.
Before Operating Ventilator
-
Engine is shipped without oil. With engine in a level position, remove oil fill plug and dipstick. Fill to outer edge
of the oil filler hole with the recommended oil. See the BRIGGS & STRATTON ENGINE Owner’s Manual for oil viscosity recommendations and capacity. -
Always operate this ventilator with unleaded gasoline having a pump octane rating of 86 or higher.
-
A complete inspection of the ventilator should be made prior to operation.
-
Check all threaded fasteners for proper tightness.
-
Inspect inlet and outlet guards for damage or missing pieces. Replace damaged or missing guards before operating ventilator.
Operation
Caution: Check ventilator inlet and outlet guards for obstructions. Check
and remove from immediate surrounding area any objects that could be drawn
into the ventilator intake.
Check the engine oil level, running the engine with a low oil level can cause
engine damage. See the BRIGGS & STRATTON ENGINE Owner’s Manual. Check the
engine air cleaner. A dirty filter will reduce engine performance. See the
BRIGGS & STRATTON ENGINE Owner’s Manual.
Caution: Check the fuel level. Do not overfill. Starting with no more
than a 3/4 full tank will help reduce operating interruptions for refueling
and avoid fuel spillage when engine is tilted. See the BRIGGS & STRATTON
ENGINES Owner’s Manual.
Place ventilator in desired location before starting.
Refer to the BRIGGS & STRATTON ENGINE Owner’s Manual for additional
information showing locations of engine control features and positions.
Warning: Use caution not to direct toxic fumes into confined spaces with
the ventilator. Please refer to the Super Vac Training Manual for Smoke
Ventilation for comprehensive instruction on effective ventilation practices.
Starting the Engine
- Move the fuel lever to the ON position.
- If engine is cold, move choke lever to the CLOSED position.
- Move throttle lever to 1/3 of the way toward the FAST position.
- Turn the engine switch to the ON position.
- Pull the starter grip lightly until resistance is felt, then pull briskly. Do not let the starter grip return by releasing grip. This can lead to starter cord breakage. Return starter grip gently to the recoiled position.
Stopping the Engine
- Move throttle lever to the SLOW position.
- Turn engine switch to the OFF position.
- Turn the fuel valve lever to the OFF position.
Maintenance and Repair
Maintenance should only be performed by experienced and trained personnel.
Be sure the ventilator blade has come to a complete stop before performing any
maintenance or repair.
Disconnect spark plug wire from spark plug and keep it away from spark plug.
The ventilator blade should be specially checked for build-up of material or
dirt which may cause an imbalance. Excessive imbalance can lead to accelerated
wear on engine bearings and vibration. Remove ventilator guards. Clean blade
and inside housing with mild detergent and water. Do not use abrasives, sharp
instruments or caustic solvents that may scratch or damage the aluminum alloy
blade.
Schedule of Maintenance
See parts list for replacement part numbers.
Troubleshooting
Common causes of engine overheating:
- Insufficient unobstructed distance on exhaust side of ventilator. Please refer to the Super Vac Training Manual for Smoke Ventilation for recommended ventilator placement.
- Incorrect octane fuel – too low octane
ENGINE WILL NOT START | Possible Cause | Correction |
---|---|---|
Check Control Positions | Fuel Valve OFF | Move Lever to ON |
Choke is OFF | Set choke to FULL on (Unless engine is warm) | |
Throttle control is on STOP | Move the throttle control to SLOW | |
Oil Alert System | Engine oil is low or engine is being operated on too steep |
an incline.
Check Fuel| Out of fuel| Refuel
Deteriorated fuel| Drain fuel tank and carburetor. Refuel with fresh gasoline.
Contamination in fuel tank blocking fuel line| Drain fuel tank and carburetor.
Refuel with fresh gasoline.
Remove and Inspect Spark Plug| Spark plug faulty, fouled, or improper gapped|
Clean, gap, or replace spark plug.
Warranty
Super Vacuum Manufacturing Company warrants that the equipment is free from
defects in materials and workmanship when used and operated for a period of
five years. The responsibility of Super Vacuum Manufacturing Company under
this limited warranty is limited to the repair and replacement of any parts
which are found defective and which are returned to Super Vacuum Manufacturing
Company at 3842 Redman Dr, Fort Collins, CO 80524 with transportation charges
prepaid (C.O.D. shipments will not be accepted).
Prior to returning defective parts to SUPER VACUUM MANUFACTURING COMPANY, the
original purchaser shall make a claim in writing to SUPER VACUUM MANUFACTURING
COMPANY at the above address indicating the model number and type of defect.
No parts or equipment will be received by SUPER VACUUM MANUFACTURING COMPANY
for repair or replacement under this warranty without specific written
authority from it in advance.
Any parts damaged by improper installation, overloading, abuse or accident of
any type or cause are not covered by this warranty.
All equipment manufactured by us is pre-run and tested before leaving our
plant, and is shipped in good working order and condition. We therefore extend
to the original purchasers the following Limited Warranty for the period of
five years from the original date of purchase:
- This warranty does not apply to defects caused by accident, misuse, neglect, or wear and tear, nor can we be held responsible for incidental and consequential expense and loss, nor does this warranty apply to equipment where alterations have been executed without our knowledge or consent. These conditions are readily discernible when the equipment is returned to us for inspection.
- On all component parts not manufactured by SUPER VACUUM MANUFACTURING COMPANY, their warranty is to the extent that the manufacturer of such component warrants them to SUPER VACUUM MANUFACTURING COMPANY, if at all. Look in your local business phone directory for the nearest repair station for the brand of parts you have or write to us for the address.
- If equipment received is found to have been damaged in transit, a claim should be made against the carrier within three days, as we assume no responsibility for such damage.
- Any service other than our Authorized Service voids this warranty.
- This warranty is in lieu of and is intended to exclude all other warranties, express or implied, oral or written, including any warranties of MERCHANTABILITY or FITNESS for a particular purpose.
Contact Information
For parts or service information, contact:
Super Vacuum Manufacturing Company, Inc.
3842 Redman Dr.
Fort Collins, CO 80524
Phone: 800-525-5224
970-297-7100Fax: 970-297-7099
Email : info@supervac.com
Internet: www.supervac.com
Parts List
1 | 019-20304 | 1 | FRAME, RND 1.25 OD ALUM. VALOR, V-20 |
---|---|---|---|
2 | 019-20306 | 1 | HANDLE, V-20 |
3 | 019-20217 | 2 | PLATE, ADJUSTMENT LOCK,V-18, V-20 |
4 | 019-20312 | 1 | ASSEMBLY,WHEEL,ADJUSTMENT, V-20 |
5 | 019-20311 | 1 | ADJUSTMENT, FOOT LEVER, V-20 |
6 | 019-20239 | 3 | BLOCK, PEDAL AXLE MOUNT |
7 | 019-20240 | 2 | LEVER, PIVOT LOCK |
8 | 019-20241 | 2 | ROD, PULL, FOOT LEVER |
9 | STD HARDWARE-IEW-11 | 2 | WASHER,LOCK,18-8SS,INTERNAL,3/8in |
10 | STD HARDWARE W27 | 1 | WASHER,FLAT,USS, 3/8”, SS |
11 | STD HARDWARE-BHSH-83b | 1 | SCREW,BHSH,3/8-16×2-1/2,SS |
12 | STD HARDWARE-ANUT-06 | 2 | NUT,ACORN, 3/8-16 UNC, SS |
13 | STD HARDWARE–59 | 8 | SCREW,PHP,10-24 UNCx0.75 |
14 | 034-11033 | 4 | NUT,NYLOCK, 1/4-20 UNC,SS |
15 | 034-11116 | 2 | NUT,NYLOCK,THIN, 1/4-20 UNC,SS |
16 | 034-11057 | 10 | NUT,NYLOCK, 5/16-18 UNC,SS |
17 | STD HARDWARE-FHMS-157 | 2 | SCREW,FHPMS,5/16-18 UNC x 3/4 in,SS |
18 | STD HARDWARE-HHCS-236 | 4 | SCREW,HH,5/16-24×1-3/4,SS |
19 | 023-15303 | 1 | ENGINE, VANGUARD, B&S 205 |
20 | STD HARDWARE W24 | 8 | WASHER,FLAT,USS, 5/16”, SS |
21 | 017-14999 | 1 | BUSHING,1-1/4 OD,1 INCH,718, V-18 |
22 | 008-10174 | 1 | DISC,SHROUD SPACER,718-720, V-18 |
23 | 018-10336 | 1 | SHROUD, 20” W/GUARD-PAINTED |
24 | 012-10281 | 1 | GUARD,FRONT,FAN,V-20 |
25 | STD HARDWARE–57 | 14 | SCREW,PHP,10-24 UNCx0.5 |
26 | 003-10047 | 1 | 20” FAN BLADE |
--- | --- | --- | --- |
27 | 008-10193 | 1 | KEYSTOCK,SHAFT,BLADE,718, V-18 |
28 | 008-10187 | 1 | BUSHING,BLADE, MAUREY HQ 3/4 |
29 | STD HARDWARE-HHCS-08 | 2 | SCREW,HH,1/4-20×1-1/4,SS |
30 | STD HARDWARE LW35 | 2 | WASHER,LOCK,SPRING,REGULAR, 1/4”, SS |
31 | STD HARDWARE-HHCS-30 | 1 | SCREW,HH,5/16-18×3/4,SS |
32 | STD HARDWARE LW39 | 5 | WASHER,LOCK,SPRING,REGULAR, 5/16”, SS |
33 | STD HARDWARE W25 | 1 | WASHER,FLAT,FENDER, 5/16”, SS |
34 | STD HARDWARE-HHCS-35 | 4 | SCREW,HH,5/16-18×1-1/2,SS |
35 | 024-13473 | 4 | FEET RUBBER CONE SHAPE VBM-4002 |
36 | 008-13374 | 2 | WHEEL, 8 INCH |
37 | STD HARDWARE-HHCS-316 | 2 | SCREW,HH,1/2-20×3-1/2,SS |
38 | STD HARDWARE W34 | 6 | WASHER,FLAT,USS, 1/2”, SS |
39 | STD HARDWARE-NN16 | 2 | NUT,NYLOCK, 1/2-13 UNC,SS |
40 | 005-10255 | 1 | T-HANDLE, PLUNGER, VALOR |
41 | 034-10125 | 2 | ROLL PIN, 5/32 X 1 1/4 SS, VALOR |
42 | 005-10256 | 4 | PLUG, 1.25, TUBE END ROUND, VALOR |
43 | 024-15161 | 4 | PNEUMATIC MOUNTS 16340 ZN, VALOR FANS |
44 | 024-15160 | 2 | GAS SPRING, 12.00 IN, 40 LB, VALOR SERIES |
45 | 024-13284 | 2 | SPRING, COMPRESSION, TILT LEVER |
46 | STD HARDWARE-111 | 1 | SCREW,BHSH,3/8-16×3-1/2,SS |
47 | 034-10981 | 8 | NUT,NYLOCK, 10-24 UNC,SS |
48 | STD HARDWARE-HHCS-11 | 2 | SCREW,HH,1/4-20×2,SS |
49 | STD HARDWARE-HHCS-234 | 2 | SCREW,HH,5/16-24×1-1/4,SS |
Exploded View
Fire and Emergency Manufacturers and Services Association, Inc.
PO. Box 147. Lynnfield. MA 01940
www.FEMSA.org