SUPERVAC V20-BW-SP Super Vac Ventilator Fans User Guide
- June 5, 2024
- SUPERVAC
Table of Contents
READ THIS FIRST
VENTILATOR USER GUIDE
MODEL V20-BW-SP
USER GUIDE
This manual covers the description, cautions, operation, and maintenance of
the Super Vac V20-BW-SP. Please take the time to read this manual before
operating the ventilator.
Save this guide for future reference.
Breakage or Damage During Shipment
The transportation company is fully responsible for all shipping damage and
will resolve problems promptly if you handle it correctly. Please read these
instructions carefully.
Examine the contents of all shipping cases. If you find any damage, call your
transportation agent at once and have them make a description on the freight
or express bill escribing the damage and the number of pieces. Then write us
and we will send you the original bill of lading. Get a claim blank from the
express or truck company. Fill the claim form out. Attach the claim blank to
the original bill of lading together with a copy of our invoice. Attach a memo
on which you show the value of the damaged goods. Mail or hand these papers to
your local transportation agent. They will process your claim with reasonable
promptness.
Please note, that we cannot and will not enter claims for damages. If we filed
a claim here, it would be sent to your local freight agent for verification
and investigation. This time can be saved by your filing the claim directly.
Every consignee is on the ground floor and in contact with the local agent who
inspects the damaged goods, and thus, each claim can be given individual
attention. Since our goods are packed to comply with the regulations of all
railroad, truck, and express companies, we cannot allow a deduction from any
invoice because of any damage, however, be sure to file your claim promptly.
Our goods are sold F.O.B. factory. We take a receipt from the transportation
company certifying that the goods were delivered to them in good order, and
our responsibility ceases.
It is seldom that any breakage or damage occurs in any of our shipments, and
in no case will the customer be out any expense if they follow the above
instructions. Be sure to keep all damaged goods subject to examination of the
truck or express company inspector, who may call on you sometime later. These
damaged goods, of course, will belong to them, and they will inform you what
to do with them. If you dispose of these damaged goods, your claim may not be
paid.
General Description and Specifications
Super Vac ventilators are specifically designed to provide a convenient and portable source of air. Super Vac positive pressure ventilators are tested to AMCA Standard 240-15, for use in extreme conditions.
Model # | RPM | Motor | H x W x D | Weight |
---|---|---|---|---|
V20-BW-SP | 2000 | 1 HP Variable Speed DC | 28.25″ x 28.75″ x 12.5″ | 60 lbs |
specifications are subject to change without notification. Refer to the model decal affixed to a ventilator to determine actual specifications.
This ventilator is designed for high-powered air movement. Super Vac’s propeller produces a greater intake of air and reduces turbulence at the tips. Each blade is dynamically balanced for high efficiency and long life.
Product Safety Precautions
- Wear eye and ear protection when operating the ventilator.
- Never operate a ventilator while fatigued.
- Do not disassemble or modify the ventilator in any way. Doing so may lead to mechanical failure or personal injury.
- Do not wear loose clothing that could become entangled in the operating ventilator.
- Never permit anyone to operate a ventilator without proper instruction.
- Do not operate ventilator without proper inlet or outlet guards in place. If guards are missing or damaged, contact the factory for replacements.
- Do not place fingers or other foreign objects through inlet or outlet guards. Should a foreign object enter the ventilator, and immediately stop the motor? Be certain all mechanical motion has stopped. Do not use any power voltage other than the indicated voltage.
- Never handle energized power cords with wet hands.
- Do not place or operate the ventilator on unsteady tables, slanted surfaces or other unstable surfaces. Never use this ventilator in any explosive environment.
- Never let extension cords or plug connections lay in the water. Locate the ventilator so that it cannot fall into water inadvertently.
Before Operating Ventilator
4. Before Operating Ventilator
- This ventilator will work with any M28 battery from the Milwaukee brand.
- A complete inspection of the ventilator should be made prior to operation.
- Check all threaded fasteners for proper tightness.
- Check ventilator inlet and outlet guards for obstructions. Check and remove from the immediate surrounding area any objects that could be drawn into the ventilator intake.
- Replace damaged or missing guards before operating the ventilator.
- Never store or carry the battery pack so that metal objects can contact exposed battery terminals. Transporting batteries can possibly cause fires if the
- battery terminals contact with loose nails, screws, keys, hand tools, and the like.
- If using shore or mains power:
o Never use power cords with frayed, cut, or brittle insulation.
o Inspect the power cord plug for proper connections to the ground fault interrupter circuit.
Airflow vs Setback
Operation
-
Use caution not to direct toxic fumes into confined spaces with the ventilator. Please refer to the Super Vac Training Manual for Smoke Ventilation for comprehensive instruction on effective ventilation practices.
-
Insert a Milwaukee M28 battery. Only one battery is necessary. The battery will click when fully inserted.
-
The fan will need to be reset (turned off & on) if a new battery is inserted.
-
If the fan is not reset, then the fan will not recognize the new battery and run until the previous battery is empty.
-
If using shore (mains) power, use an extension cord to connect to a 110 – 240V AC, 50/60Hz power source.
-
Press and hold the power button until the blue backlight indicates powering up.
-
When the fan is on, it will need to run at the minimum speed allowed by Milwaukee. (This feature is to protect the batteries from small parasitic draws)
-
Turn speed control clockwise until the desired speed is reached.
-
The power button will indicate the approximate power left. (It is normal for colors to flicker back and forth if 2 batteries are being used)
o Green: 50 – 100%
o Yellow: 20 – 50%
o Red: 0 – 20% (Low Battery Warning: Front Facing LED will also flash if turned on) -
To turn off, press and hold the power button until blue backlight shows.
Battery Run Times at Max Speed
Runtimes dependent on air density, temperature, and age of batteries. Test data showed taken at 5000ft elevation, 25% RH, 70°F with new batteries.
Air density is primarily affected by elevation, humidity, and temperature.
*At temperatures below freezing expect battery life to decrease.
Charging the Battery Packs
- Remove Milwaukee batteries from the fan.
- Insert in Milwaukee Charger for M28 batteries. Use only Milwaukee brand battery chargers.
- When the battery pack temperature is outside the charging range (40-105°F or 5-40°C), the red light on the charger will flash and the battery will not charge.
- Once the battery pack is within the acceptable temperature range, normal charging will take place.
- Using the Milwaukee M28 charger, the XC3.0 battery will charge in about 45 minutes, while the XC5.0 battery will charge in 80 minutes or less.
CAUTION:
- Do not store battery packs or chargers above 120°F (50°C) or in direct sunlight.
- Never use chargers or batteries in explosive atmospheres.
- Never attempt to open the battery pack. If cracked or damaged, return it to a service center for recycling.
- Do not splash or immerse the charger in water or other liquids.
Maintenance and Repair
Maintenance should only be performed by experienced and trained personnel.
If you have any questions, contact Super Vac before attempting any maintenance
at info@supervac.com or
1-800-525-5224.
To-Do Checklists:
Daily/After Each Use: | Weekly/Monthly/Quarterly: | Yearly: |
---|
• Charge batteries completely
• Check that Guards are undamaged and effectively prevent objects from
contacting the blade
• Wheels and feet are in place and tight
• Tilt Mechanism works properly
• If the tilt adjust is too loose, tighten the knurled nut on the Tilt
Mechanism.
• For larger adjustments, tighten nut with a 9/16” (14mm) wrench.
|
• Calibrate Battery
• Fully charging, then fully discharging, and fully charging once again before
storage
• Replace the battery (-ies) if battery shows signs of damage from dropping or
excessive heat
• Check for loose fasteners
• Check the condition of the power cord (if purchased with Shore Power) (14mm)
wrench.
|
• Battery Condition
• Check runtime in low wind and average temperature conditions
• If runtime is below 75% of advertised runtime, replacing batteries is
recommended
• Excessive vibration
• Blade imbalance due to accumulation of dirt on the blade
• Check Blade interference
• Remove the front guard and rotate manually to check for interference
Warranty
Milwaukee products carry a separate 3-year limited warranty for compatible
battery packs and chargers. For more information, contact them at
www.milwaukeetool.com or
1-800-729-3878.
Super Vacuum Manufacturing Company warrants that the equipment is free from
defects in materials and workmanship when used and operated for a period of
five years, excluding the motor which has a 3-year warranty. The
responsibility of Super Vacuum Manufacturing Company under this limited
warranty is limited to the repair and replacement of any parts which are found
defective and which are returned to Super Vacuum Manufacturing Company at 3842
Redman Dr, Fort Collins, CO 80524 with transportation charges prepaid (C.O.D.
shipments will not be accepted).
Prior to returning defective parts to SUPER VACUUM MANUFACTURING COMPANY, the
original purchaser shall make a claim in writing to SUPER VACUUM MANUFACTURING
COMPANY at the above address indicating the model number and type of defect.
No parts or equipment will be received by SUPER VACUUM MANUFACTURING COMPANY
for repair or replacement under this warranty without specific written
authority from it in advance.
Any parts damaged by improper installation, overloading, abuse or accident of
any type or cause are not covered by this warranty. All equipment manufactured
by us is pre-run and tested before leaving our plant and is shipped in good
working order and condition. We, therefore, extend to the original purchasers
the following Limited Warranty for the period of five years from the original
date of purchase:
- This warranty does not apply to defects caused by accident, misuse, neglect, or wear and tear, nor can we be held responsible for incidental and consequential expense and loss, nor does this warranty apply to equipment where alterations have been executed without our knowledge or consent. These conditions are readily discernible when the equipment is returned to us for inspection.
- On all component parts not manufactured by SUPER VACUUM MANUFACTURING COMPANY, their warranty is to the extent that the manufacturer of such component warrants them to SUPER VACUUM MANUFACTURING COMPANY, if at all. Look in your local business phone directory for the nearest repair station for the brand of parts you have or write to us for the address.
- If equipment received is found to have been damaged in transit, a claim should be made against the carrier within three days, as we assume no responsibility for such damage.
- Any service is other than our Authorized Service voids this warranty.
- This warranty is in lieu of and is intended to exclude all other warranties, express or implied, oral or written, including any warranties of MERCHANTABILITY or FITNESS for a particular purpose.
Kontakt
For parts or service information, contact:
Super Vacuum Manufacturing Company, Inc.
3842 Redman Dr.
Fort Collins, CO 80524
Phone: 800-525-5224
970-297-7100
Fax: 970-297-7099
Email : info@supervac.com
Internet: www.supervac.com
Parts List
ITEM| QTY| PART NUMBER| DESCRIPTION| 33| 4| 005-10271| GROMMET,PUSH-IN,0.75
ID,1.125 OD,0.0938 GROOVE
---|---|---|---|---|---|---|---
1| 1| 019-20541| FRAME WELDMENT, V20-BX| 34| 1| 012-15394| STREAMSHAPER GUARD
FOR 20″ SMOKE FAN
2| 4| 024-13473| FEET RUBBER CONE SHAPE VBM-4002| 35| 1| 019-20540| WLDMNT
HANDLE, V20-BX
3| 1| 019-20509| TUBE WHEEL SPACER, V20-BX| 36| 1| 005-18003| BOX TOP
ELECTRIC, V20-BX
4| 2| 012-14196| INSERT, 3/8-16, TUBE, V1X-BX AXLE MOUNT| 37| 1| 005-18004|
BOX TOP ELECTRIC COVER, V20-BX
5| 2| 008-13804| WHEEL, V1X-BX, 6 INCH| 38| 2| STD HARDWARE-FHMS-159|
SCREW,FHPMS,5/16-18 UNC x 1 in,SS
6| 2| 019-20518| PLASTIC STAIR SKID, V20-BX| 39| 2| 032-10789| NUT,NYLON,
5/16-18 UNC,SS
7| 1| 005-18005| BOX POWER SUPPLY, V20-BX| 40| 4| FHMS Phillips-10736|
SCREW,FHPMS,1/4-20 UNC x 3/8 in,SS
8| 8| STD HARDWARE-FHMS-84| SCREW,FHPMS,10-24 UNC x 5/8 in,SS| 41| 1|
005-13564| SWITCH, LATCHING, V1X-BX
9| 4| 032-10713| NUT,NYLON, 10-24 UNC,SS| 42| 1| 005-13562| SWITCH, MOMENTARY,
RGB, V1X-BX
10| 1| 005-18006| BOX POWER SUPPLY COVER, V20-BX| 43| 1| 065-00923|
POTENTIOMETER, V1X-BX
12| 1| KDS-DE 7-8 BK| CDXX-CONMAXX Seals| 44| 1| 005-10267| KNOB,
POTENTIOMETER, V1X-BX
13| 2| 005-18012| CDXX-CONMAXX Seals| 45| 1| 005-10255| T-HANDLE, PLUNGER,
VALOR
14| 2| 005-18014| CDXX-CONMAXX Seals| 46| 4| STD HARDWARE-SHCSM71|
SCREW,SHCS,SHCS M6x1x10
16| 1| 008-14131| | 47| 1| 019-20533| PLATE COVER MOTOR, V20-BX
17| 2| STD HARDWARE–42| SCREW,PHP,8-32 UNCx0.375| 48| 1| 003-15320| BUSHING,
BLADE, V1X-BX
18| 13| STD HARDWARE-SHCS-42| SCREW,SHCS,10-24×3/8,SS| 49| 2| 032-10745|
SCREW,HH,1/4-20×1,SS
19| 21| STD HARDWARE-SHCS-28| SCREW,SHCS,8-32×3/8,SS| 50| 6| 032-10754|
WASHER,LOCK,SPRING,REGULAR, 1/4″, SS
20| 1| 019-20543| SHROUD WLDMNT, V20-BX| 51| 8| 034-10963| SCREW,PHP,10-24
UNCx0.5
21| 1| 005-18001| BOX CONTROLLER, V20-BX| 52| 3| STD HARDWARE-SHCSM34|
SCREW,SHCS,SHCS M4x0.7×8
22| 2| 005-18015| CDXX-CONMAXX Seals| 53| 2| 032-10120| WASHER, PLASTIC, 5/16
23| 1| 005-18002| BOX CONTROLLER COVER, V20-BX| 54| 1| 003-15340|
Blade_21in_25Deg_V20-BX
24| 1| 021-10514| CONTROLLER, HG, 18V / 36V DC MOTOR| 55| 1| 008-14165|
KEYSTOCK, MOTOR, BM, VALOR, BATTERY
25| 1| 98420A157_WIDE-GRIP SIDE-MOUNT EXTERNAL RETAINING RING| 56| 2|
032-14564| SCREW,BHSH,3/8-16×2-1/2,SS
27| 4| STD HARDWARE–12| SCREW,PHP,4-40 UNCx0.25| 57| 1| V20_BX_Square_Logo|
28| 1| 005-10270| WASHER, RUBBER, ROTATION, V1X-BX| 58| 1| 025-16020| DECAL,
SHROUD, CENTER, V1X-BX
29| 1| 005-10266| HANDLE, TENSION, V1X-BX| 59| 1| 025-16030| DECAL, SHROUD,
CHEVRON, V16-BX
30| 1| 034-11073| NUT,NYLON, 3/8-16 UNC,SS| 60| 23| 032-10142| INSERT, BRASS
HEAT-SET, 8/32
31| 6| 005-10256| PLUG, 1.25, TUBE END ROUND, VALOR| 61| 4| 032-10143| INSERT,
BRASS HEAT SET, 10/24
32| 2| 005-13563| LIGHT, LED, V1X-BX| 62| 4| 032-10140| INSERT, BRASS HEAT-
SET, 4/40
Exploded View
V20-BW-SP PPV User
Revised 6-2021
Documents / Resources
|
SUPERVAC V20-BW-SP Super Vac Ventilator
Fans
[pdf] User Guide
V20-BW-SP, Super Vac Ventilator Fans
---|---
References
- Milwaukee® Tool Official Site | Nothing but HEAVY DUTY®
- Super Vac Ventilation Fans | Firefighter Ventilation & Industrial Ventilation Fans