SUPERVAC V18-BL Fire-End and Croker User Guide

June 5, 2024
SUPERVAC

V18-BL Fire-End and Croker
User Guide

This manual covers the description, cautions, operation, and maintenance of the Super Vac V18-BL.
Please take the time to read this manual before operating the ventilator.
Save this guide for future reference.

Breakage or Damage During Shipment

The transportation company is fully responsible for all shipping damage and will resolve problems promptly if you handle it correctly. Please read these instructions carefully.
Examine the contents of all shipping cases. If you find any damage, call your transportation agent at once and have them make a description on the freight or express bill describing the damage and the number of pieces. Then write us and we will send you the original bill of lading. Get a claim blank from the express or truck company. Fill the claim form out. Attach the claim blank to the original bill of lading together with a copy of our invoice. Attach a memo on which you show the value of the damaged goods. Mail or hand these papers to your local transportation agent. They will process your claim with reasonable promptness.
Please note, that we cannot and will not enter claims for damages. If we filed a claim here, it would be sent to your local freight agent for verification and investigation. This time can be saved by your filing the claim directly. Every consignee is on the ground floor and in contact with the local agent who inspects the damaged goods, and thus, each claim can be given individual attention.
Since our goods are packed to comply with the regulations of all railroad, truck, and express companies, we cannot allow a deduction from any invoice because of any damage, however, be sure to file your claim promptly. Our goods are sold F.O.B.
factory. We take a receipt from the transportation company certifying that the goods were delivered to them in good order, and our responsibility ceases.
It is seldom that any breakage or damage occurs in any of our shipments, and in no case will the customer be out at any expense if they follow the above instructions.
Be sure to keep all damaged goods subject to examination of the truck or express company inspector, who may call on you sometime later. These damaged goods, of course, will belong to them, and they will inform you what to do with them. If you dispose of these damaged goods, your claim may not be paid.

General Description and Specifications

Super Vac ventilators are specifically designed to provide a convenient and portable source of air. Super Vac positive pressure ventilators are tested to AMCA Standard 240-15, for use in extreme conditions.

Model # RPM Motor H x W x D Weight
V18-BL 2000 1 HP Variable Speed DC 25.50″ x 26″ x 12.25″ 54 lbs

Specifications are subject to change without notification. Refer to the model decal affixed to a ventilator to determine actual specifications.
This ventilator is designed for high-powered air movement. Each blade is dynamically balanced for high efficiency and long life.

Product Safety Precautions

  • Do not use the ventilator for purposes other than it’s intended use.
  • Wear eye and ear protection when operating the ventilator.
  • Never operate a ventilator while fatigued.
  • Do not disassemble or modify the ventilator in any way. Doing so may lead to mechanical failure or personal injury.
  • Do not wear loose clothing that could become entangled in the operating ventilator.
  • Never permit anyone to operate a ventilator without proper instruction.
  • Do not operate ventilator without proper inlet or outlet guards in place. If guards are missing or damaged, contact the factory for replacements.
  • Do not place fingers or other foreign objects through inlet or outlet guards. Should a foreign object enter the ventilator, and immediately stop the motor? Be certain all mechanical motion has stopped. Do not use any power voltage other than the indicated voltage.
  • Never handle energized power cords with wet hands.
  • Do not place or operate the ventilator on unsteady tables, slanted surfaces, or other unstable surfaces. Never use this ventilator in any explosive environment.
  • Never let extension cords or plug connections lay in the water. Locate the ventilator so that it cannot fall into water inadvertently.
  • Never store or carry the battery pack so that metal objects can contact exposed battery terminals. Transporting batteries can possibly cause fires if the battery terminals contact with loose nails, screws,  keys, hand tools, and the like.

Before Operating Ventilator

  • This ventilator will work with any M18 battery from the Milwaukee brand.

  • A complete inspection of the ventilator should be made prior to operation.
    • Check all threaded fasteners for proper tightness.
    • Check ventilator inlet and outlet guards for obstructions. Check and remove from the immediate surrounding area any objects that could be drawn into the ventilator intake.
    • Replace damaged or missing guards before operating the ventilator.

  • Never store or carry the battery pack so that metal objects can contact exposed battery terminals. Transporting batteries can possibly cause fires if the battery terminals contact with loose nails, screws,  keys, hand tools, and the like.

  • If using shore or mains power:
    o Never use power cords with frayed, cut, or brittle insulation.
    o, Inspect the power cord plug for proper connections to the ground fault interrupter circuit.

Airflow vs Setback

SUPERVAC V18 BL Fire End and Croker - figure 1

Operation

  • Use caution not to direct toxic fumes into confined spaces with the ventilator.

  • Insert a Milwaukee M18 battery until it clicks. Only a single battery is necessary for operation.

  • Battery removal will get easier with more remove/replace cycles. The Battery Adapter & M18 Battery interface is required by Milwaukee.

  • The fan will need to be reset (turned off & on) if a new battery is inserted.

  • If the fan is not reset, then the fan will not recognize the new battery and run until the previous battery is empty.
    • If using shore (mains) power, use an extension cord to connect to 110 – 240V AC.

  • Press and hold the power button until the blue backlight indicates powering up.

  • When the fan is on, it will need to run at the minimum speed allowed by Milwaukee. (This feature is to protect the batteries from small parasitic
    draws)

  • Turn speed control clockwise until the desired speed is reached.

  • The power button will indicate the approximate power left. (It is normal for colors to flicker back and forth if 2 batteries are being used)
    • Green: 50 – 100%
    • Yellow: 20 – 50%
    • Red: 0 – 20% (Low Battery Warning: Front Facing LED will also flash if turned on)

  • To turn off, press and hold the power button until blue backlight shows.

Battery Run Times at Max Speed

SUPERVAC V18 BL Fire End and Croker - figure 2

  • Runtimes dependent on air density, temperature, and age of batteries. Test data showed taken at 5000ft elevation, 25% RH, 70°F with new batteries.
  • Air density is primarily affected by elevation, humidity, and temperature.
  • At temperatures below freezing expect battery life to decrease.
  • Other M18 Batteries will operate the fan, but at reduced runtimes.

Charging the Battery Packs

  • Remove Milwaukee batteries from the fan.
  • Insert in Milwaukee Charger. Use only Milwaukee brand battery chargers.
  • When the battery pack temperature is outside the charging range (40-105ºF or 5-40ºC), the red light on the charger will flash and the battery will not charge.
  • Once the battery pack is within the acceptable temperature range, normal charging will take place.
  • Using the Milwaukee SuperCharger™, a 12 Amp-hour battery will recharge in 60 minutes and an 8 Amp hour battery will recharge in 45 minutes.
  • Other Milwaukee chargers, including units that work with vehicle DC power, may take longer to fully charge the batteries.

CAUTION:

  • Do not store battery packs or chargers above 120ºF (50ºC) or in direct sunlight.
  • Never use/store chargers or batteries in explosive atmospheres.
  • Never attempt to open the battery pack. If cracked or damaged, return it to a service center for recycling.
  • Do not splash or immerse the charger in water or other liquids.

Maintenance and Repair

Maintenance should only be performed by experienced and trained personnel.
If you have any questions, contact Super Vac before attempting any maintenance at info@supervac.com or 1-800-525-5224.
To-Do Checklists:

Daily/After Each Use:

  • Charge batteries completely
  • Check that Guards are undamaged and effectively prevent objects from contacting the blade
  • Wheels and feet are in place and tight
  • The tilt mechanism works properly
  • If the tilt adjust is too loose, tighten the knurled nut on the Tilt Mechanism.
  • For larger adjustments, tighten the nut with a 9/16” (14mm) wrench.

Weekly/Monthly/Quarterly:

  • Calibrate Battery
  • Fully charging, then fully discharging, and fully charging once again before storage
  • Replace the battery (-ies) if battery shows signs of damage from dropping or excessive heat
  • Check for loose fasteners
  • Check the condition of the power cord (if purchased with Shore Power) (14mm) wrench.

Yearly:

  • Battery Condition
  • Check runtime in low wind and average temperature conditions
  • If runtime is below 75% of the advertised runtime, replacing batteries is recommended
  • Excessive vibration
  • Blade imbalance due to accumulation of dirt on the blade
  • Check Blade interference
  • Remove the front guard and rotate manually to check for interference

Warranty

Milwaukee products carry a separate 3-year limited warranty for the compatible battery packs, chargers, and ODM battery adapter. For more information contact them at www.milwaukeetool.com or 1- 800-729-3878.
Super Vacuum Manufacturing Company warrants that the equipment is free from defects in materials and workmanship when used and operated for a period of five years, excluding the motor which has a 3-year warranty. The responsibility of Super Vacuum Manufacturing Company under this limited warranty is limited to the repair and replacement of any parts which are found defective and which are returned to Super Vacuum Manufacturing Company at 3842 Redman Dr, Fort Collins, CO 80524 with transportation charges prepaid (C.O.D. shipments will not be accepted).
Prior to returning defective parts to SUPER VACUUM MANUFACTURING COMPANY, the original purchaser shall make a claim in writing to SUPER VACUUM MANUFACTURING COMPANY  at the above address indicating the model number and type of defect. No parts or equipment will be received by SUPER VACUUM MANUFACTURING COMPANY for repair or replacement under this warranty without specific written authority from it in advance.
Any parts damaged by improper installation, overloading, abuse or accident of any type or cause are not covered by this warranty.
All equipment manufactured by us is pre-run and tested before leaving our plant and is shipped in good working order and condition. We, therefore, extend to the original purchasers the following  Limited Warranty for the period of five years from the original date of purchase:

  1. This warranty does not apply to defects caused by accident, misuse, neglect, or wear and tear, nor can we be held responsible for incidental and consequential expense and loss, nor does this warranty apply to equipment where alterations have been executed without our knowledge or consent. These conditions are readily discernible when the equipment is returned to us for inspection.
  2. On all component parts not manufactured by SUPER VACUUM MANUFACTURING COMPANY, their warranty is to the extent that the manufacturer of such component warrants them to  SUPER VACUUM MANUFACTURING COMPANY, if at all. Look in your local business phone directory for the nearest repair station for the brand of parts you have or write to us for the address.
  3. If equipment received is found to have been damaged in transit, a claim should be made against the carrier within three days, as we assume no responsibility for such damage.
  4. Any service is other than our Authorized Service voids this warranty.
  5. This warranty is in lieu of and is intended to exclude all other warranties, express or implied, oral or written, including any warranties of MERCHANTABILITY or FITNESS for a particular purpose.

Contact

For parts or service information, contact:
Super Vacuum Manufacturing Company, Inc.
3842 Redman Dr.
Fort Collins, CO 80524

Phone:| 800-525-5224
970-297-7100
---|---
Fax:| 970-297-7099
Email :
Internet:| info@supervac.com
www.supervac.com

Parts and Exploded Views

Fan Parts List

SUPERVAC V18 BL Fire End and Croker - figure 3

PARTS LIST

ITEM| QTY| PART NUMBER| DESCRIPTION| ITEM| QTY| PART NUMBER| DESCRIPTION
1| 1| 019-20286| FRAME, WLDMNT V18-BL| 32| 4| 032-10119| SCREW,HH,M5x0.8×12,SS
2| 1| 019-20267| BOX, POWER SUPPLY, V1X-BX (OPTIONAL)| 33| 1| 021-10524| COVER, MOTOR, V1X-BX
3| 10| 033-10874| NUTSERT, TSN RIBBED, 10-24 (OPTIONAL)| 34| 4| 032-10118| SCREW,PPH,M3 X 0.5 x 8 mm
4| 1| 005-15355| POWER SUPPLY, 750W, 24V, V18-BL| 35| 1| 034-11073| NUT,NYLOCK, 3/8-16 UNC,SS
5| 1| 019-20268| COVER, POWER SUPPLY, V1X-BX (OPTIONAL)| 36| 1| 005-10266| HANDLE, TENSION, V1X-BX
6| 3| 032-10096| SCREW,SHCS,SHCS M4x0.7×6| 37| 1| 019-20275| HANDLE, V1X-BX
7| 3| 065-12852| STRAIN RELIEF,DOMED,SCR .24-.47,1/2 NPT,BLACK| 38| 1| 019-20288| MILWAUKEE BATTERY MOUNT SPACER
8| 2| 065-12856| LOCKNUT,NYLON,1/2 NPT,BLACK| 39| 1| 019-20287| MILWAUKEE BATTERY MOUNT LOWER
9| 4| 032-10757| SCREW,PHP,10-24 UNCx0.75| 40| 2| 005-16103| ADAPTER, MILWAUKEE, ODM, V1X-BX
10| 4| 024-13473| FEET RUBBER CONE SHAPE VBM-4002| 41| 2| 032-10121| SCREW,FHPMS,4-40 UNC x 5/16 in,SS
11| 2| 012-14196| INSERT, 3/8-16, TUBE, V1X-BX AXLE MOUNT| 42| 4| 032-10122| SCREW,FHPMS,4-40 UNC x 3/4 in,SS
12| 1| 019-20253| TUBE, WHEEL SUPPORT, V1X-BX| 43| 4| 4-40 Nut Steel|
13| 2| 008-13804| WHEEL, V1X-BX, 6 INCH| 44| 2| 4-40 Nut Plastic|
14| 2| 032-14564| SCREW,BHSH,3/8-16×2-1/2,SS| 45| 2| 032-10110| SCREW,FHPMS,5/16-18 UNC x 7/8 in,SS
15| 10| 005-10256| PLUG, 1.25, TUBE END ROUND, VALOR| 46| 2| 032-10789| NUT,NYLOCK, 5/16-18 UNC,SS
16| 1| 019-20266| COVER, CONTROLLER BOX, V1X-BX| 47| 1| 005-10255| T-HANDLE, PLUNGER, VALOR
17| 1| 021-10514| CONTROLLER, HG, 18V / 36V DC MOTOR| 48| 4| 032-10123| NUT, 4-40, ZINC
18| 1| 065-00920| SHORE PLUG, V1X-BX| 49| 8| 032-10695| NUT,MS,HEX2,8-32UNC,SS
19| 4| 032-10101| SCREW,PHP,8-32 UNCx0.5| 50| 8| STD HARDWARE-FHMS-66| SCREW,FHPMS,8-32 UNC x 3/4 in,SS
20| 14| 034-10963| SCREW,PHP,10-24 UNCx0.5| 51| 1| 065-00923| POTENTIOMETER, V1X-BX
21| 1| 005-10269| BUSHING, ROTATION, V1X-BX| 52| 1| 005-10267| KNOB, POTENTIOMETER,V1X-BX
22| 2| 005-10271| GROMMET,PUSH-IN,0.75 ID,1.125 OD,0.0938 GROOVE| 53| 1| 019-20291| WIRING COVER PLATE, V18-BL
23| 1| 005-13563| LIGHT, LED, V1X-BX| 54| 2| 032-10754| WASHER,LOCK,SPRING,REGULAR, 1/4″, SS
24| 1| 005-10270| WASHER, RUBBER, ROTATION, V1X-BX| 55| 4| STD HARDWARE-28| WASHER,LOCK,SPRING,REGULAR, #10, SS
25| 1| 019-20276| SHROUD, V1X-BX| 56| 2| 005-16100| BATTERY, MILWAUKEE, 12AH, V1X-BX
26| 1| 012-15393| STREAMSHAPER GUARD FOR 18″ PPV FAN| 57| 1| 005-13562| SWITCH, MOMENTARY, RGB, V1X-BX
27| 1| 025-16020| DECAL, SHROUD, CENTER, V1X-BX| 58| 1| 005-13564| SWITCH, LATCHING, V1X-BX
28| 1| 008-10193| KEY STOCK,SHAFT,BLADE,718, V-18| 59| 1| 025-16018| DECAL, SHROUD, CHEVRON, V1X-BX
29| 1| 003-15320| BUSHING, BLADE, V1X-BX| 60| 1| 025-16016| DECAL, TOP, V1X-BX
30| 2| 032-10743| SCREW,HH,1/4-20×3/4,SS| 61| 1| 025-16017| DECAL, SERIAL NUMBER, V1X-BX
31| 1| 021-10523| MOTOR,1 HP TEA0,48VDC, V1X-BX| 62| 1| 025-16019| DECAL, SIDE, V18, V1X-BX
| 63| 1| 003-15320| BLADE, PLASTIC, 30DEG, 18″, V1X-BX (ALUMINUM BLADE AVAILABLE)

Fan Exploded View

SUPERVAC V18 BL Fire End and Croker - figure 4

PARTS LIST PARTS LIST
ITEM QTY
PART NUMBER DESCRIPTION
1 1

PLUNGER, VALOR
2| 1| 005-18005| BOX POWER SUPPLY, VXX-BX| 32| 1| 005-10268| VALOR, POTENTIOMETER, VXX-BX
3| 1| 005-18020| BOX POWER SUPPLY GASKET, V20-BX| 33| 1| 005-10267| KNOB, POTENTIOMETER, V1X-BX
4| 1| 005-18006| BOX POWER SUPPLY COVER, V20-BX| 34| 2| 005-18015| SEAL, CONTA-CLIP – 13-14 mm
5| 2| 008-13804| WHEEL, V1X-BX, 6 INCH| 35| 1| 005-13563| LIGHT, LED, V1X-BX
6| 4| 024-13473| FEET RUBBER CONE SHAPE VBM-4002| 36| 1| 005-18012| SEAL, CONTA-CLIP – 5MM
7| 1| 019-20509| TUBE WHEEL SPACER, V20-BX| 37| 2| 005-10271| GROMMET,PUSH- IN,0.75 ID,1.125 OD,0.0938 GROOVE
8| 2| 012-14196| INSERT, 3/8-16, TUBE, V1X-BX AXLE MOUNT| 38| 2| 032-10120| WASHER, PLASTIC, 5/16
9| 1| 021-10514| CONTROLLER, HG, 18V / 36V DC MOTOR| 39| 2| 032-24486| SCREW, 5/16-18 UNC X 1 in, PFMS, SS, BLACK
10| 6| 005-10256| PLUG, 1.25, TUBE END ROUND, VALOR| 40| 2| 032-10789| NUT, NYLON, 5/16-18 UNC,SS
11| 1| 005-18003| BOX TOP ELECTRIC, VXX BX| 41| 4| 032-22550| SCREW, 10-24 UNC X 1/2 in, PFMS, SS, BLACK, PATCH
12| 1| 005-18004| BOX TOP ELECTRIC COVER, VXX-BX| 42| 6| 032-22482| SCREW, 10-24 UNC X 1/2 in, PFMS, SS, BLACK
13| 1| 005-13564| SWITCH, LATCHING, V1X-BX| 43| 2| 032-22414| SCREW, 10-24 UNC X 1/2 in, PPMS, SS, BLACK, PATCH
14| 1| 005-13562| SWITCH, MOMENTARY, RGB, V1X-BX| 44| 3| 032-22821| SCREW, 10-24 UNC X 3/8 in, BHCS, SS, BLACK, PATCH
15| 1| 019-20699| FRAME WLDMENT, V18-BW| 45| 21| 032-21886| SCREW, 8-32 UNC X 3/8 in, SHCS, SS, BLACK
16| 1| 019-20622| WLDMNT HANDLE, V18-BX| 46| 25| 032-22249| 0-RING, 8-32 UNC, HARDWARE BUNA
17| 1| 005-18001| BOX CONTROLLER, VXX-BX| 47| 4| STD HARDWARE–208| SCREW,PHP,4-40 UNCx0.313
18| 1| 005-18002| BOX CONTROLLER COVER, VXX-BX| 48| 6| 032-22618| SCREW, 10-24 UNC X 1/2 in, SHCS, SS, BLACK
19| 1| 005-18021| BOX CONTROLLER GASKET, VXX-BX| 49| 4| 032-21888| SCREW, 8-32 UNC X 5/8 in, SHCS, SS, BLACK
20| 1| 005-18051| PLASTIC, SLEEVE MOUNT, V18-BX| 50| 6| 032-22980| 0-RING, 10-24 UNC, HARDWARE BUNA
21| 1| 005-18053| PLASTIC, SLEEVE LOCK, VXX-BX| 51| 1| 034-11073| NUT, NYLON, 3/8-16 UNC,SS
22| 2| 019-20604| PLASTIC STAIR SKID, V18-BX| 52| 2| STD HARDWARE-BHSH-77| STD HARDWARE-BHSH-77, 3/8-16×2-1/2, SS
23| 1| 005-18010| SEAL, CONTA-CLIP- BLANK| 53| 3| 032-27672| SCREW, M4X0.7 ANSI M, 8mm, BHCS, SS, BLACK, PATCH
24| 27| 032-10142| INSERT, BRASS HEAT-SET, 8/32| 54| 4| 032-24011| SCREW, 1/4-20 UNC X 3/8 in, PFMS, SS, BLACK, PATCH
25| 4| 032-10140| INSERT, BRASS HEAT-SET, 4/40| 55| 2| 032-21682| SCREW, 8-32 UNC X 3/8 in, PPMS, SS, BLACK, PATCH
26| 4| 032-10143| INSERT, BRASS HEAT SET, 10/24| 56| 1| 019-20551| HANDLE, CAM LOCK ASSY, VXX BX
27| 1| 005-18014| SEAL, CONTA-CLIP – 10MM| 57| 6| 032-10880| nutsert, 10-24, .02-.13 GRIP RANGE
28| 2| 005-18017| SEAL, CONTA-CLIP – 9-10 mm| 58| 2| 032-22982| NUT, 10-24 UNC, INSERT, .13-.225 GRIP RANGE
29| 1| 008-14131| PLASTIC, PAC CORD CLAMP| 59| 1| 025-16032| DECAL, SV LOGO, SIDE, VXX-FX
30| 1| 005-10180| CORD, POWER SUPPLY, 120VAC, 24 IN.| 60| 1| 005-18026| SEAL, SLEEVE MOUNT, VXX-BX

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals