TREON Industrial Node 6 Ex User Guide

June 3, 2024
TREON

Industrial Node 6 Ex
Quickstart Guide,
Safety, and Warranty
v 1.3 EN

Product description

Treon Industrial Node is a wireless battery- operated sensor device for condition monitoring and predictive maintenance. It measures tri-axial vibration and surface temperature of rotating equipment, such as pumps, motors and compressors. Abnormal machine vibrations or high temperatures may give early signs of failure due component imbalance, misalignment, wear or improper use of equipment.
Treon Industrial Node 6 Ex variant is designed for vibration and temperature monitoring of rotating equipment in potentially explosive atmospheres.
Treon Industrial Node operates in a mesh network transmitting sensor values directly or via other nodes to a gateway, such as Treon Gateway. Typically, the data is sent from the gateway to a cloud backend for storage and further analysis.
Once the node is switched on, it starts automatically to measure and transmit data at pre-confi gured intervals. Depending on confi guration Treon Node can send raw vibration data and/or pre-calculated values, such as RMS velocity, Fast Fourier transform (FFT) and Kurtosis, to the cloud via the gateway.

When using the device in potentially hazardous environment

Failure to follow the instructions in this guide could result in a serious personal injury and property damage and may void warranty. Read this guide carefully before installing or using the device. Save the guide for future reference.
When installed, the sensor must be grounded to the machine.
Treon disclaims all responsibility for work done by untrained and unauthorized personnel.
These are the personnel requirements for Ex-approved products in potentially explosive atmospheres:

  • All users must know about the risks of electric current and the chemical and physical characteristics of the gas and/or vapor present in hazardous areas.
  • The installation for Ex-approved products  must be made in conformity to theinternational or national standards (IEC/ EN 60079-17).

Treon Industrial Node 6 Ex is certifi ed for use in
potentially explosive atmospheres.
ATEX & IECEx markings
II 2 G Ex ib IIC T4 Gb
II 2 D Ex ib IIIC T135°C Db
Ambient Temperature: -40°C to +60°C | -40°F to +140°F
MET markings
Class I Zone 1 AEx ib IIC T4 Gb
Zone 21 AEx ib IIIC T135°C Db
Class I, Division 2, Groups A,B,C,D T4
Class II, Division 2, Groups F,G T4
Class III, Division 2
Ex ib IIC T4 Gb
Ex ib IIIC T135°C Db
Ambient Temperature: -40°C to +60°C | -40°F to +140°F
Compliant with the following standards:
ATEX
EN IEC 60079-0:2018
EN 60079-11:2012
IECEx
IEC 60079-0:2017
IEC 60079-11:2011
North America
UL 60079-11 (Edition 6) 2013 rev 2018
UL 60079-0 (Edition 7) 2019 rev 2020
CSA C22.2 NO 60079-11 (Edition 2) 2014
CSA C22.2 NO 60079-0 (Edition 4) 2019

Keys and parts

A. Status light
B. Orientation notch
C. Power button
D. NFC tag
E. M8 bolt
F. Nut adapter
G. Magnetic epoxy mount adapter

H. Glue mount adapter*

  • Note that adapters F, G, and H are not included in standard sales box.

Mounting the Node

equipment, it is important to consider the location of the sensor and the contact between the sensor and the equipment. Best location to attach the sensor depends on the machine and the monitored vibration source.
For best measurement quality, the contact  surface in the machine should be completelyfl at (within 1 mil), smooth (surface texture no greater than 32 microinches) and larger than the base of the node. It’s recommended that nodes are mounted via a drilled and tapped hole directly to the machine housing.
In cases where the surface of the machine is curved or uneven, epoxy must be used between the machine surface and the node. Screwing the node to curved surface may lead to the node bolt twisting and permanent damage to the device.

  When installed in a potentially hazardous area, the sensor must be installed in such a way that it is grounded or connected by electrostatic dissipative adhesive to the machine surface. Grounding can be achieved by mounting the device directly to machine body by tap and drill. Electrostatic dissipative adhesive must be used when sensor is mounted using glue mount adapter or magnetic epoxy mount adapter. Paint must be removed from machine surface before adhesive mounting. For more information, contact support@treon.fi.
CASE 1
Attach node directly to machine surface
Direct attachment between the Industrial Node and machine surface minimizes the vibration transmission route for best measurement qual- ity. It requires a fl at surface of 32mm diameter and hole for M8 bolt with 18.5mm of threading.

  1. Clean the machine surface and apply silicon grease on it.
  2. Apply service removable thread lock to the sensor bolt.
  3. Insert the bolt into a M8 hole in the machine.
  4. Screw the node with 30mm torque wrench to 8 newton meters torque.

CASE 2
Attach node with nut adapter
Using a nut adapter enables attaching the Industrial Node to a spot with less available space in diameter, shorter M8 opening with less threading and with additional epoxy to uneven surface. It requires a nut adapter, fl at surface of 25mm diameter, hole for M8 bolt with 9.5mm of threading and optional epoxy.

  1. Clean the surfaces between node and adapter and apply silicon grease on it.

  2. Screw the adapter nut to the sensor bolt.

  3. Tighten the nut to 8Nm torque.
    Without epoxy

  4. Clean the machine surface and apply silicon grease on it.

  5. Apply service removable thread lock to the sensor bolt.

  6. Insert the bolt into a M8 hole in the machine.

  7. Screw the node with 22mm torque wrench to 8 newton meters torque.

TREON Industrial Node 6 Ex-fig2

With epoxy
4. Apply Epoxy to nut adapter surface.
5. Insert the bolt into a M8 hole in the machine.
6. Hand tighten the sensor.
7. Let the epoxy harden.

CASE 3
Attach node with epoxy or glue mount adapter
Using epoxy or glue mount adapter enables attaching Industrial Node without an opening for a bolt. With epoxy mount adapter the Industrial Node can also be attached to slightly uneven surface while glue mount adapter requires an even surface. Required surface diameter is 32mm.

  1. Clean the surfaces between node and adapter and apply silicon grease on it.
  2. Screw the mount adapter to the sensor bolt.
  3. Tighten the nut to 8Nm torque.
  4. Apply epoxy or glue to adapter surface.
  5. Place the node to the correct position on the machine.
  6. Let the epoxy or glue harden.

Aligning the node
For accurate interpretation of the measurement data, the centerline of the node is often aligned with the shaft of the rotating machine. This can be done by manually aligning the node with the shaft.
Manual alignment requires using the epoxy or glue mount adapter. After applying the fi xative and hand tightening the sensor to the machine, align the node axis directly toward drive or nondrive end of monitored machine. Turn the node only clockwise.

Switch on the node
Press and hold the power button until the status light turns green. If you want to switch off the node, press the power button until the status light turns red.

Check the connection

To see if the node is connected to the gateway:
1. Press the power button briefl y. The status light turns green and goes off .

2. If the status light then turns green again, the node is connected.
CONNECTED
If the status light turns red, the node is not yet connected.
NOT CONNECTED

In case the node is not connected, the Gateway  has been powered on and the node has hadtime to establish the connection, the node may be too far from the gateway or surroundings are blocking the radio connection. In either case, the gateway needs to be moved closer to the node or an additional routing node can be added between the node and the gateway to help routing the data.

Read the Node ID

The identifi cation number of the node is printed on the sticker attached to the node, and it can be as well read from the QR code.

TREON Industrial Node 6 Ex-fig5

www.treon.fi

You can also use a NFC reader, such as an NFC-enabled mobile phone to read the identifi cation number: switch on NFC on the reader and touch the top of the node with the reader.

Use only Ex certifi ed devices in potentially hazardous environments.

TREON Industrial Node 6 Ex-fig6

Product info

Important
For important info on the safe use of your device, read the Safety Guide.
Operating frequencies: 2400MHz – 2483.5MHz Maximum power: +4 dBm
Operating temperature range:
In potentially explosive atmospheres -40 to +60°C
In other normal environments -40 – +85°C
Battery
Battery type: 3.6V A lithium thionyl chloride (LI-SOCI2) bobbin cell primary battery.
Do not charge, short circuit, crush, dissemble, heat above 100°C (212°F), incinerate or expose the battery contents to water.
The battery is non-removable. If the battery wears out, replace the node.
NORWAY. This device is not allowed to be used within a 20 km radius of the centre of Ny-Ålesund at Svalbard, Norway.
CERTIFICATION INFORMATION
Manufacturer
Treon Oy, Visiokatu 3, 33720 Tampere, Finland.
SUPPLIER’S DECLARATION OF CONFORMITY
Product name: Treon Industrial Node 6 Ex
Unique Identifi er: Treon Industrial Node, model 2111, variant 6k Ex
Manufacturer:
Treon Oy
Visiokatu 3, FIN-33720 Tampere, Finland
https://www.treon.fi
Responsible Party – U.S. Contact Information:
OptoFidelity Inc.
19409 Stevens Creek Blvd. – Suite 250, Cupertino, CA 95014, USA
http://www.optofidelity.com
+1 669-241-8383

FCC Compliance Statement (for products subject to Part 15)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Canada
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment.

EU DECLARATION OF CONFORMITY
Hereby, Treon Oy declares that the radio equipment Treon Industrial Node is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:
https://www.treon.fi/documentation

Safety guide and Warranty

Introduction
Read these simple guidelines. Not following them may be dangerous or against local laws and regulations. For further information visit:
https://www.treon.fi/documentation
Care and maintenance
Handle your device with care. The following suggestions help you keep your device operational.
• Do not open the device other than as instructed in the user guide.
• Unauthorized modifi cations may damage the device and violate regulations governing radio devices.
• Do not drop, knock, or shake the device. Rough handling can break it.
• Only use a soft, clean, dry cloth to clean the surface of the device.
Do not clean the device with solvents, toxic chemicals or strong
detergents as they may damage your device and void the warranty.
• Do not paint the device. Paint can prevent proper operation.
• The node is dust and splash proof. However, it is not recommended to immerse it in water.
Safety distance
Safety distance 150 mm from the magnetic mount adapter surface must be kept due to high strength magnets. Damage
If the device is damaged contact support@treon.fi. Only qualifi ed personnel may repair this device.
Small children
Your device is not a toy. It may contain small parts. Keep them out of the reach of small children.
Interference with medical devices
The device may emit radio waves, which could aff ect the operation of nearby electronics, including cardiac pacemakers, hearing aids and defi brillators. If you have a pacemaker or other implanted medical device, do not use the device without first consulting your doctor or the manufacturer of your medical device. Maintain a safe distance between the device and your medical devices and stop using the device if you observe a persistent interference with your medical device.

Storage
Always store and use the device with covers attached. Device storage temperature is +0 – +30°C.
Recycle
Check the local regulations for proper disposal of electronic products.
The Directive on Waste Electrical and Electronic Equipment (WEEE),
which entered into force as European law on 13th February 2003, resulted in a major change in the treatment of electrical equipment atend-oflife. The purpose of this Directive is, as a first priority, the prevention of WEEE, and in addition, to promote the reuse, recycling and other forms of recovery of such wastes so as to reduce  disposal.
The crossed-out wheelie-bin symbol on your product, battery, literature, or packaging reminds you that all electrical and electronic products and batteries must be taken to separate collection at the end of their working life. Do not dispose of these products as unsorted municipal waste: take them for recycling. For info on your nearest recycling point, check with your local waste authority.