Maiwe Industrial Ethernet Switch User Manual
- June 3, 2024
- maiwe
Table of Contents
Industrial Ethernet Switch
User Manual
Packing list
MIEN3020G-4GC-16GT
MIEN3028G-4GC-24GT
The package of this switch contains the following items. If any item is found
to be missing or damaged, please contact the agent or the customerservice
center of Maiwe for ssistant.
Items | Quantity | Remarks |
---|---|---|
Industrial Ethernet Switc | 1PCS | |
Power cord | 1PCS | AD220 model only |
User Manual | 1PCS |
Product description
This series isThis switch is an unmanaged rack-mount industrial Ethernet switch.MIEN3020G-4GC-16GT(4 Gigabit Combo ports+16 Gigabit RJ45 ports), MIEN3028G- GC-24GT provides 28 ports (4 Gigabit combo ports+24 Gigabit RJ45 ports).
Interface description
Unit:mm
Take MIEN3028G-4GC-24GT as a example:
1. Indicator lights | 5.Power input terminal |
---|---|
2.Gigabit RJ45 port | 6. Ground screw |
3. Gigabit combo port | 7. Rack mounting ears |
4. Relay alarm output terminal |
[Connect the power]
The switch supports AD220V single power input, using 5-position locking
terminals with 5.08mm pitch.
Number | Pin definition |
---|---|
1 | Power 1 Input V1+(AC-L)/Positive(DC) |
2 | Power 1 Input V1-(AC-N)/Negative (DC) |
3 | Grounded |
4 | Power 2 Input V2+(AC-L)/Positive(DC) |
5 | Power 2 Input V2-(AC-N)/Negative (DC) |
[Connect to the relay]
This series of switches supports the relay alarm function, and the wiring
terminals use 3-position 5.08mm pitch terminals. This relay is a normally open
and a normally closed elay, the middle one is the common terminal, the left
two terminals are normally open relays, and the right two terminals are
normally closed relays. When the switch is orking normally, the normally open
relay is powered and closed, and the normally closed relay is disconnected.
The recommended switching load capacity of the relay is 1A (24VDC).
Number | Pin definition |
---|---|
1 | Alarm relay output normally open |
2 | Alarm relay output common terminal |
3 | Alarm relay output normally closed |
The switch indicator lights description is shown in the table below:
Indicator lights | Statu | Definition |
---|
System Status LED
WR1/PWR2| On| The power is connected and operating normally
Off| The power is not connected or the system is
RUN| Flashing| The system is operating normally
On/Off| The system is not working properly
ALM| On| Device power failure alarm, port offline alarm,
network storm alarm
Off| Device no alarm
Ethernet Port Status LED (Front panel network port indicator)
1G(Yellow)| On| 1G working status
Off| 10M or 100M working status
RJ45 Port Status LED
Indicator lights| Statu| Definition
---|---|---
System Status LED
PWR1/PWR2| On| The power is connected and operating normally
Off| The power is not connected or the system is
RUN| Flashing| The system is operating normally
On/Off| The system is not working properly
ALM| On| Device power failure alarm, port offline alarm,
network storm alarm
Off| Device no alarm
1G(Yellow| On| 1G working status
Off| 10M or 100M working status
RJ45 Port Status LED
Link/Act (Green)| On| The port has established a valid network
connection
Flashing| There is network activity on the port
Off| No valid network connection is established on the port
Real panel network port indicator
1-28| On| The port has established a valid network connection
Flashing| There is network activity on the port
Off| No valid network connection is established on the port
[Installation Size]
Hardware Installation
Installation Precautions
To prevent equipment damage or personal injury caused by improper use, observe
the following precautions:
- During the installation process, you need to wear anti-static gloves or anti-static gloves, and power-off the switch.
- Please make sure that the input voltage is within the input voltage range marked on the switch.
- The transmission distance has a certain relationship with the connected wire. It is recommended to use a standard Cat5e/6 network cable.
- The equipment must be grounded for lightning protection, otherwise the protection level of the equipment will be greatly reduced; please use a wire of No.20 or more to connect the grounding terminal to the ground.
- The power line, ground line and signal line are laid out separately and the distance is not less than 5cm
[Device installation] Install rack-mounted equipment
Rack-mounted installation, the installation steps are as follows:
- Step 1 Select the installation location of the device and make sure it has sufficient size.
- Step 2 Use 2 screws to install the mounting ear to the position of the device as shown in the figure below.
- Step 3 Put the device on the rack, and use 4 screws to fix the left and right side brackets to the rack respectively.
- Step 4 Check and confirm that the product is securely installed on the rack, and the installation is complete.
[Device connection]
- Step 1 Connect one end of the ground wire to a suitable position, and fix the ground plate on the switch panel with washers and screws.
- Step 2 Connect the power cord to the switch’s power terminals.
- Step 3 Connect the network cable to the RJ45 port of the switch.
- Step 4 Insert the SFP optical module into the SFP port and connect the fiber-to-fiber transceiver.
Specifications
MIEN3020G-4GC-16GT | MIEN3028G-4GC-24GT |
---|
Switch properties
Bandwidth| 56Gbps
Cache size| 4.1Mbit
MAC table| 8K
Interface
Gigabit SFP| 1000Base-X
Gigabit SFP port| SFP slot
10/100/1000Base-TXRJ45 ports
Gigabit RJ45 port| Full-duplex/half-duplex adaptive, supports MDI/MDI-X
adaptive
Consumption| 24W(MAX)
AC power inp| Standard AC85~264V (frequency: 47~63Hz) or DC110~370V (Dual
power is optional)
Size| 482.6mm×44mm×210mm(L×W×H)
Installation| 19’1U standard rack mount
Heat| Aluminum alloy single-rib chassis surface scattered
IP protection| IP40
Weight| About3kg
Working environment
Working Temp.| -40℃~+75℃
Storage Temp.| -40℃~+85℃
Humidity| 5%~95%(No condensation)
Industry Standard
EMC| IEC61000-4-2(ESD), Level 4
IEC61000-4-5(Surge), Level 4
※Ethernet ports support 6KV lightning protection
IEC61000-4- 4(EFT), Level 4
IEC61000-4-3(RS), Level4
IEC61000-4-6(CS), Level4
Order guide
Item | Gigabit Combo ports | Gigabit RJ45 ports | Power |
---|---|---|---|
MIEN3020G-4GC-16GT | 4 | 16 | AC85~264V (freq.: 47~63Hz) or DC110~370V (Dual |
power is optional)
MIEN3028G-4GC-24GT| 4| 24
Pledge
Thank you for purchasing Maiwe products. You will enjoy the following
services when using Maiwe products. We solemnly promises: under normal use,
one month’s return, one-year free maintenance, five-year warranty, and
lifetime maintenance. The specific details are as follows:
- If Maiwe products have quality problems and cannot work normally, they will be refunded for one month, free maintenance for one year, warranty for five years, and maintenance for life.
- If the number of repaired products is less than 10, the repair service will be completed within 7 days (excluding transportation time), and the repair service will be completed within one month for more than 10 sets.
- Optical passive products such as optical fibers, optical cables, jumpers, flanges, and optical cable terminal boxes are guaranteed within two years, but no return service is provided.
- The accessories and power supply that come with the product are guaranteed for one year.
- When sending the product back to Maiwe for repair, it is recommended that the customer use the original packaging or the packaging with the same protective effect, otherwise the customer shall bear the risks that occur during the transportation.
- The repaired product can enjoy another 6 months warranty service.
- The product after-sales service is detailed in the purchase and sale contract, and Maiwe has the final interpretation right of this descriptio
Wuhan Maiwe Communication Co., Ltd.
Add: Building E2, No. 2 Building, Area E, No. 52 Liufang Avenue, East lake
High-tech Development Zone, Wuhan, China.
Tel: 027-87170215/16
Post Code: 430205
Fax: 027-87170217
Site: www.maiwe.com
Statement
Due to the continuous updating and improvement of products and technologies,
the contents of this manual will be updated from time to time. All the
information in the manual is only used for instructions, if the content in the
text does not completely match the actual product, please understand and
please contact our customer service in time.
Copyright 2021 Maiwe Communication All rights reserved.
The right to interpret the information published in this material belongs to
Wuhan.
Maiwe Communication Co., Ltd.
References