Maiwe MIEN2208 Series Industrial Ethernet Switch
Packing list
The package of this switch contains the following items. If any item is found to be missing or damaged, please contact the agent or the customer service center of Maiwe for assistant.
Items | Quantity | Remarks |
---|---|---|
Industrial Ethernet Switch | 1PCS | |
Power cord | 1PCS | AD220 model only |
User Manual | 1PCS |
Product Description
The switch is an unmanaged din-rail industrial Ethernet switch. MIEN2208 series provides 8 100M Ethernet interfaces. Among them, MIEN2208-F (1 100M fiber and 7 100M copper ports), MIEN2208-2F (2 100M fiber and 6 100M copper ports), MIEN 2208-4F (4 100M fiber and 4 100M copper ports).
Interface description
Take MIEN2208-2F as an example.
Item | Description |
---|---|
Ground screw | Crimp one end of the grounding screw with the cold-pressed |
terminal. The other end of the grounding wire is connected to the ground, and
the grounding wire is not less than 2.5mm2
Power interface| Support Dual DC12-48V or DC48V(36-72V).
Support single power input AC85-264V or DC110-370V.
Relay output interface| Relay alarm output function; this relay is a normally
open and one normally closed relay, the middle one is the common terminal, the
two left terminals are normally open relays, and the two right two terminals
are normally closed relays. When the switch works normally, the normally open
relay is energized and closed, and the normally closed relay is disconnected.
When the system is powered down, the normally open relay is powered off and
the normally closed relay is closed. The recommended switching load capacity
of the relay is 1A (24VCD).
Ethernet RJ45 port| Supports automatic MDI/MDI-X connection. You can connect
the switch to terminal devices, servers, hubs, or other switches.
---|---
Fiber port| The 100M fiber port is a 100Base-FX full-duplex single-mode or
multi-mode fiber connector, which support single-fiber or dual- fiber
connectors, and the connector can be SC, ST or FC. The optical fiber
connectors must be used in pairs (TX and RX are a pair).
Din-rail kit| To fix the switch.
The indicator description of the switch is shown in the following table.
Indicator lights | Status | Definition |
---|
System Status LED
PWR1/PWR2| On| The power is connected and operating normally
Off| The power is not connected or the system is not operating normally
RUN| Flashing| The system is operating normally (some models are always on to
indicate normally)
Off| The system is not working properly
Fiber Port Status LED
LINK| On| The port has established a valid network connection
Flashing| There is network activity on the port
Off| No valid network connection is established on the port
RJ45 Port Status LED
Each RJ45 port has two indicator lights, the yellow light is the port plastic
rate indicator, the
green light is the port connection status indicator.
10/100M (Yellow)| On| 100M working state (namely 100Base-TX)
Off| 10M working status (namely 10Base-T)
Link/Act (Green)| On| The port has established a valid network connection
Flashing| There is network activity on the port
Off| No valid network connection is established on the port
Hardware installation
Installation Precautions
To prevent equipment damage or personal injury caused by improper use, observe
the following precautions:
- During the installation process, you need to wear anti-static gloves or anti-static gloves, and power-off the switch.
- Please make sure that the input voltage is within the input voltage range marked on the switch.
- The transmission distance has a certain relationship with the connected wire. It is recommended to use a standard Cat5e/6 network cable.
- The equipment must be grounded for lightning protection, otherwise the protection level of the equipment will be greatly reduced; please use a wire of No. 20 or more to connect the grounding terminal to the ground.
- The power line, ground line and signal line are laid out separately and the distance is not less than 5cm.
Device installation
-
Tilt the switch upwards so that the upper end of the buckle is fastened to the upper end of the DIN rail.
-
The lower end of the back buckle is buckled into the DIN rail.
-
Network cables connection
Connect the optical fiber and network cable to the port in the correct . -
Optical fiber connection
Connect the optical fiber to the corresponding optical fiber interface. The optical fiber interface is used in pairs (TX and RX as a pair), TX is optical receiver, RX is optical sender. -
Power input
Before connecting the power cord, make sure that the ground is connected. Do connect the power cord to the power terminal of the device according to the definition.
Notes
- When using a switch, the voltage can only be input from V1+ and V1-, V1+ connects to live wire L, and V1- to neutral wire N. Do not connect from V2+, V2-; pay attention to safety and prevent electric shock.
- Power-on operation: First connect the power cord to the power terminal of the device according to the definition shown in the figure above, and then power on.
- Power-off operation: first unplug the power plug, and then remove the power cord.
Specifications
MIEN2208-F | MIEN2208-2F | MIEN2208-4F |
---|
Switch performance
Backplane bandwidth| 1.6G
Cache size| 768Kbit
MAC address| 2K
Interface
100Base-FX port| 1100Base-FX| 2100Base-FX| 4100Base-FX
Connector SC/FC/ST optional
100Base-TX port| 710 /100Base-TX
RJ45 ports
| 6*10 /100Base-TX
RJ45 ports
| 4*10/100Base-TX
RJ45 ports
With adaptive function, support MDI/MDI-X connection
Power
Power consumption| <5W@24V full load
DC input| Support dual DC12~48V or DC48V (36-72V) power supply
AC input| AC85~264V (frequency: 47~63Hz) or DC110~370V
Mechanical
Size| 138mm×54mm×110mm(H×W×D)(Excluding DIN rail)
Installation method| 35mm standard DIN rail installation
Heat dissipation form| Aluminum alloy single-rib chassis surface heat
dissipation, no fan.
Weight| About 0.67kg
IP protection| IP40
Working environment
Operating temp.| -40~+85℃
Storage temp.| -40~+85℃
Humidity| 5~95% (No condensation)
Industry-standard
EMC| IEC61000-4-2(ESD), Level4
IEC61000-4-5(Surge), Level4 IEC61000-4-4(EFT), Level4
Order Guide
Model | 100Base-FX | 100Base-TX | Power |
---|---|---|---|
MIEN2208-F | 1 | 7 | DC power supply: |
DC12~48V or DC48V (36~72V) optional
AC power supply: AC85~264V(Freq.:47~63Hz) or DC110〜
370V
MIEN2208-2F| 2| 6
MIEN2208-4F| 4| 4
Pledge
Thank you for purchasing Maiwe products. You will enjoy the following services
when using Maiwe products.
We solemnly promises: under normal use, one month’s return, one-year free
maintenance, five-year warranty, and lifetime maintenance. The specific
details are as follows:
- If Maiwe products have quality problems and cannot work normally, they will be refunded for one month, free maintenance for one year, warranty for five years, and maintenance for life.
- If the number of repaired products is less than 10, the repair service will be completed within 7 days (excluding transportation time), and the repair service will be completed within one month for more than 10 sets.
- Optical passive products such as optical fibers, optical cables, jumpers, flanges, and optical cable terminal boxes are guaranteed within two years, but no return service is provided.
- The accessories and power supply that come with the product are guaranteed for one year.
- When sending the product back to Maiwe for repair, it is recommended that the customer use the original packaging or the packaging with the same protective effect, otherwise the customer shall bear the risks that occur during the transportation.
- The repaired product can enjoy another 6 months warranty service.
- The product after-sales service is detailed in the purchase and sale contract, and Maiwe has the final interpretation right of this description.
Wuhan Maiwe Communication Co., Ltd.
Add: Building E2, No. 2 Building, Area E, No. 52 Liufang Avenue, East
lake
High-tech Development Zone, Wuhan, China.
Tel: 027-87170215/16
Fax: 027-87170217
Post Code: 430205
Site: www.maiwe.com
Statement
Due to the continuous updating and improvement of products and technologies,
the contents of this manual will be updated from time to time. All the
information in the manual is only used for instructions, if the content in the
text does not completely match the actual product, please understand and
please contact our customer service in time.
Copyright 2021 Maiwe Communication All rights reserved.
The right to interpret the information published in this material belongs to
Wuhan Maiwe Communication Co., Ltd.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>