Maiwe MIEN2208 Unmanaged Industrial Ethernet Switch User Manual
- June 9, 2024
- maiwe
Table of Contents
Maiwe MIEN2208 Unmanaged Industrial Ethernet Switch
Trademark
This trademark is owned by Wuhan Maiwe Communication Co., Ltd.
Mwring is the trademark used for link redundancy and self-recovery
technology, owned by Wuhan Maiwe Communication Co., Ltd.
Microsoft and Windows is registered trademark owned by Microsoft.
Copyright
Copyright © Wuhan Maiwe Communication Co., Ltd.
Clarification
The user manual is applicable to MIEN2208 series of industrial unmanaged
ethernet switch.
Please read the following license agreement carefully before using this
manual. The products described in this manual can be used only if you agree on
the following license agreement.
Important Statement
Any information provided by our company in this manual does not represent for
corresponding authorization on these information.
Our company attempts to ensure the accuracy and applicability for the
information provided in this manual, however our company does not assume any
responsibility for the use of these information, and does not assume any joint
responsibility for the use of these information. There may be a few technical
or typographical errors in the product and manual. The company reserves the
right to change all or part of this manual without prior notice.
Statement
Due to continuous update and improvement of products and technology, the
contents of this document may not be completely consistent with the actual
products, appreciate for your understanding. If necessary to inquiry the
updates of the product, please check our official website or contact our
representative directly.
Revision history:
Version | Date | Reason |
---|---|---|
V1.0 | 2011.08 | Create files |
V2.0 | 2016.10 | Product update |
V3.0 | 2017.06 | Product update |
Safe Use Instruction
This product performance is excellent and reliable in the designed range of use, but it’s necessary to avoid man-made damage or destroy for the equipment.
- Read the manual carefully and keep this manual for reference if need afterwards.
- Do not put the device close to the water sources or damp places.
- Do not put anything on the power cable, it should be placed out of reach.
- To avoid causing fire, do not knot or wrap the cable.
- Power connector and other device connectors should be firmly connected with each other, frequently inspection is needed.
- Please keep the fiber socket and plug clean. Do not look directly at the fiber section when the equipment is working.
- Please keep the equipment clean and wipe it with a soft cotton cloth if necessary.
- Please do not repair the equipment by yourself, unless there is clear instructions in the manual.
Under the following circumstances, please cut off power immediately and contact us.
- Equipment water damage.
- The equipment is broken or the casing is broken.
- The equipment works abnormally or the performance has completely changed.
- The equipment produces odor, smoke or noise.
Statement: Information requiring explanation in use of the managed
software.
Attention: Matters requiring specific attention in the use of the managed
software.
Product Overview
Product Introduction
The MIEN2208 series products produced by Maiwe are high-performance industrial
Ethernet switches. The products provide industrial din-rail installation
methods, which can adapt to various harsh working environments and have stable
communication performance.
The product provides 1 fiber 7 copper ports, 2 fiber 6 copper ports, 4 fiber 4
copper and 8 copper ports models for users to choose from, among which the
optical port is 100Base-FX single mode or multimode fiber interface, and the
electrical port is 10Base-T/100Base-TX Ethernet RJ45 port, each RJ45 port has
an adaptive function, can be automatically configured to 10Base-T or 100Base-
TX state and full-duplex or half-duplex operation mode, and can automatically
perform MDI / MDI-X connection.
Features
Industrial network performance
- Support 8-channel 100M Ethernet interface
- Support 1 configurable alarm output
- Store and forward mechanism, the switching bandwidth is 1.6Gbps (2.0Gbps for 4 optical and 4 copper products)
- 100Mbps electrical port 10 / 100M self-adaptive, full / half duplex, MDI / MDIX self-adaptive mode
- Meet the requirements of trouble-free work under strong electromagnetic interference environment.
Industrial application design
- Storm suppression (only 4 fiber 4 copper ports support)
- Din-rail installation
Industrial power supply design
- Various power supply options are available:
- DC power standard input DC12 ~ 48V, optional DC48V (36 ~ 72V)
- AC power input DC110 ~ 370V and AC85 ~ 264V
- DC power supply models support dual power supply redundant input, AC power supply models support only single power supply input power supply models support only single power supply input protection
- Relay alarm output function, can be connected with other sound and light alarm equipment
Rugged design
- Single-ribbed aluminum chassis heat dissipation surface design, fanless efficient heat dissipation, the system can reliably work in the environment of -40 ~ +85 ℃ (AC power model working range is -25 ~ 70 ℃)
- High-strength closed aluminum shell, so that the system can work reliably in harsh and dangerous industrial environment
- Standard DIN rail type installation, and can also provide accessories for other installation methods
Packing List
The package of MIEN2208 series products contains the following items. If any of the following items are lost or destroyed, please contact the agent or the customer service center of Maiwe, who will assist you in replacing or making up.
Packing list
Item | Number |
---|---|
MIEN2208 series switch | 1 |
User manual | 1 |
Product Selection
Available models | Port | Voltage rage |
---|---|---|
Standard models | 100M copper port | 100M Fiber port(SC/ST/FC) |
Single mode | Single mode |
fiber
| Multi mode
MIEN2208| 8| | | |
- DC power supply: DC12 ~ 48V, DC48V (36 ~ 72V).
- AC power supply: DC110 ~ 370V or AC85~ 264Vadaptiv e
MIEN2208-S| 7| 1| |
MIEN2208-TS| 7| | 1|
MIEN2208-M| 7| | | 1
MIEN2208-2S| 6| 2| |
MIEN2208-2TS| 6| | 2|
MIEN2208-2M| 6| | | 2
MIEN2208-4S| 4| 4| |
MIEN2208-4TS| 4| | 4|
MIEN2208-4M| 4| | | 4
MIEN2208GE| 8| | |
Attention
Among the above models, MIEN2208GE supports DC12 ~ 48V power supply, other
models can choose one of the three power supplies according to demand.
Technical Index
System indicators | MIEN2208 |
---|---|
RJ45 port | 10Base-T/100Base-TX |
Fiber port | 100Base-FX |
System parameters | Support standards: IEEE 802.3i, IEEE 802.3u Switching |
bandwidth: 1.6Gbps (2.0Gbps for 4 fiber and 4 copper products)
Packet forwarding rate: 1.19Mpps (4fiber 4 copper is 1.488Mpps)
MAC address table: 1K (4fiber ports+4 copper ports are 2K)
Exchange method: store and forward
Broadcast storm suppression (supported by 4 optical models only)
Copper port parameters| Physical interface: RJ45 with shield
RJ-45port:10Base-T/100Base-TX,support auto-negotiation function
Interface standard: comply with IEEE802.3 standard Transmission distance: 100 meters
Fiber port parameters| Luminous power:> -12dBm (single mode)> -17dBm (multimode)
Receiver sensitivity: <-38dBm (single mode) <-35dBm (multimode)
Wavelength: 1310nm (single mode) 1550nm (single mode) 1310nm (multimode)
Transmission distance: 20 – 80Km optional (single mode) <5Km (multimode)
Connector type: SC / FC / ST Transmission rate: 155Mbps
Power parameters| Input voltage:
DC power input range: DC12 ~ 48V and DC48V (36 ~ 72V) (support dual power redundant input)
AC power input range: AD220V (AC85 ~ 264V / DC110 ~ 370V) (single power supply)
Input power consumption: <5W @ 24VDC (of which MIEN2208 and MIEN2208GE power consumption is less than 2W)
Overcurrent protection: built-in
Working environment| Working temperature: -25~ +70 ℃ (AC power supply model)
-40~ +85 ℃ (DC power supply model) Storage temperature: -40~ +85 ℃
Humidity: 5~ 95% (no condensation)
---|---
Hardware Installation and Testing
Hardware Structure
Machine mechanism
The chassis of MIEN2208 series switches is DIN rail structure, and the whole
machine adopts a six-sided fully enclosed structure. Among them, the
dimensions of MIEN2208 (excluding DIN rail) are: 144mm x 33mm x97mm (H xW x D,
and the dimensions of MIEN2208GE The dimensions of DIN rails are not
included): 95mm x43mm x90.5mm (H xW x D), the overall dimensions of MIEN2208-S
/ 2S / 4S are 138mm x54mm x 110mm (height x width xdepth).
Front Panel and Side Panel
There are three types of front panel structure types for MIEN2208 series
switches: MIEN2208, MIEN2208GE and MIEN2208-S / 2S / 4S, as shown in below:
MIEN2208 front panel
MIEN2208GE front panel
MIEN2208-S front panel
MIEN2208-2Sfront panel
MIEN2208-4S front panel
MIEN2208 and MIEN2208GE switches are equipped with a 6-position 5.08mm pitch terminal on the side panel, as shown in below:
MIEN2208 series MIEN2208-S / 2S / 4S type switch side panel is equipped with a 5-position lock 5.08mm pitch terminal
MIEN2208-S / 2S / 4S model power supply and relay terminal schematic power
input
The DC power supply models of MIEN2208 series switches support DC12 ~ 48V
power supply by default, users can choose DC48V, support dual power input, and
two power supplies are mutually backup.
The AC power models of MIEN2208 series switches support DC110 ~ 370V and AC85
~ 264V. When using AC models, V can only be input from V1 + and V1-, V1 + is
connected to the live wire L, and V1- is connected to the neutral wire N.
Connect V2 + and V2-, and pay attention to safety to prevent electric shock.
Power-down alarm output
MIEN2208 series switches support alarm function. MIEN2208 and MIEN2208GE
models have normally closed nodes, and MIEN2208-S / 2S / 4S models support
normally closed nodes and normally open nodes. When the switch works normally,
the normally closed node is opened and the normally open node is closed. When
the system is powered off, the normally closed node is closed and the normally
open node is opened. The recommended switch load capacity of the relay is 1A
(24VDC). Users can use relay contact output to connect other sound and light
alarm devices.
LED indicator
The LED indicators on the front panel of MIEN2208 series switches can show the
system operation and the status of ports, which is convenient for finding and
solving faults.
Description of LED indicator
LED | Conditions | State |
---|
System status LED
PWR1/ PWR2| On| Power connected and operating normally
Off| Power unconnected or the system is abnormal
RUN| Blinking| The system is operating normally (some models are always on to
indicate normal)
Off| The system is abnormal
Fiber port status LED
LINK| On| The port has established a valid network connection
Blinking| Network activity on the port
off| No valid network connection
Ethernet RJ45 port status LED
Each Ethernet RJ45 port has two indicators. The yellow indicator is the port
rate indicator and the green indicator is the port connection status
indicator.
10/100M
(Yellow)
| On| 100M working state ( 100Base-TX)
Off| 10M working state (10Base-T)
LINK/ACT(Green)| On| The port has established a valid network connection
| Blinking| Network activity on the port
---|---|---
Off| The port doesn’t establish a valid network connection
Hardware Installation
Din-rail installation
- For most industrial applications, it is very convenient to install with 35mm standard DIN rail. When you remove the device from the packing box, the DIN rail connection seat should be fixed on the rear panel of the MIEN2208 series switch. If MIEN2208 series switches need to be mounted on DIN rail, you should check the installation of DIN rail before installation. It includes the following two contents:
- Whether the DIN rail is fixed and strong, whether other equipment is installed on the DIN rail, and whether there is enough space for installing the switch.
- Weather Is there any power supply suitable for the work of this switch on the DIN rail.
- After selecting the installation location of the switch, install the switch on the DIN rail as follows:
- Insert the upper part of the DIN rail into the snap groove of the upper part of the DIN rail connection seat with a snap spring. Push down slightly on the top panel of the switch and rotate the device as shown in below
Install MIEN2208 series switches to Dil-rail
-
Cable connection
After the MIEN2208 series switches are correctly installed, the cables can be installed and connected, mainly including the cable connections of the following interfaces. -
RJ45 interface
The terminal equipment interface provided by MIEN2208 series switches is a 10Base-T / 100Base-TX Ethernet RJ45 interface, which uses a DC network cable to connect to the terminal equipment and a crossover network cable to connect to the network equipment. -
Connecting Power
MIEN2208 series switches use power according to the instructions on the product label. When all other cables are connected, the power can be connected
Fiber connecting
The1- fiber , 2-fiber and 4-fiber models of MIEN2208 series switches provide
100Base-FX full-duplex single-mode or multimode fiber interfaces. The type of
optical fiber interface can choose SC / ST / FC according to demand.
Attention
This switch uses a laser to transmit signals on fiber optic cables. The laser
meets the requirements of Class 1 laser products, and normal operation is not
harmful to the eyes. However, when the device is powered on, do not look
directly at the optical transmission port and the end face of the fiber
terminator.
The steps to connect pluggable fiber optic modules are as follows:
- Remove and keep the rubber sleeve of the SC / ST / FC port. When not in use, put on a rubber sleeve to protect the fiber optic terminator paper towel or cotton ball and gently wipe the cable plug. A dirty fiber terminator will reduce the quality of the optical transmission and affect the port performance
- Connect one end of the optical cable to the optical fiber interface and the other end to the optical fiber interface of another device
- After the connection is completed, please check the LINK / ACT indicator of the corresponding optical port on the front panel.
Simple Test
System self-check
When the device is powered on, all service port indicators on the front panel
flash one at a time, indicating that the switch has been powered on. When the
RUN indicator flashes, the switch starts to work normally.
Copper port test
As below picture, Power on the switch, connect any two copper ports to the
network ports of the two test computers through a directly connected network
cable, and send Ping commands to each other. Both parties can correctly ping
each other without packet loss. At the same time, the yellow light on the
corresponding port should be always on (the computer network card works in
100M state) or off (the computer network card works in 10M state), and the
green light on the corresponding port should flash. It means that the hardware
of the tested two copper ports is working normally. The following test diagram
takes the 8 copper port products of MIEN2208 series switches as an example.
Fiber port testing
The equipment with optical fiber interface is formed into the optical fiber
chain network as shown in below (TX connects to another RX, RX connects to
another TX). Each copper port of each device is connected to the test computer
through a directly connected network cable, and sends Ping commands to each
other, so that both parties can correctly ping each other without packet loss.
At the same time, the LINK light corresponding to the optical port should
flash, indicating that the hardware of the two optical ports under test is
working properly. Below is a schematic diagram of the optical port test using
the 2 fiber 6 copper switch in MIEN2208 series switches as an example.
Maintenance and Service
Since the date of product shipped, it provides five years warranty. In the
warranty period, if there is any failure or functional product fails, it will
repair or replace free of charge for users of the product. However, these
commitments do not cover improper use, accidents, natural disasters, improper
operation or improper installation caused the damage.
To ensure that consumers benefit of products, through the following ways to
get help and problem solving:
- Internet services.
- Call the technical support office.
- Product repair or replacement.
INTERNET Service
Through the website of Wuhan Technical Support section, you can get more useful information and tips.
Technical Support Phone Services
By using the product user manual, you can connect with our technical support office, we have professional technical engineers to answer your questions, help you the first time resolve your product or issue.
The product Repair or Replacement
Product repair, replacement or refund, should first connect with our technical staff to confirm, and then sales staff to contact and get the problem handled. Above shall technical staff and sales staff through consultations, to complete the product maintenance, replacement or return.
WUHAN MAIWE COMMUNICATION CO.,LTD
Add.:Building 2, Area E, Phase ii, Optical valley core center, No.52, Liufang
road, East Lake Hi-tech Development Zone, Wuhan, China Phone: 027-87170215/16
Fax: +86-027-87170217
www.maiwe.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>