WAGAN 7410, 7411 DC to DC Battery Charger User Manual

June 3, 2024
WAGAN

7410, 7411 DC to DC Battery Charger
User ManualWAGAN 7410, 7411 DC to DC Battery
Charger

We are constantly improving our products so specifications are subject to change without notice. Visit our website for the latest product information.

25A DC to DC
Battery Charger (7410)| 40A DC to DC
Battery Charger (7411)
---|---
|
https://wagan.com/pages/use-qr-codes-here?qr=BPD31LGUY5ZC| https://wagan.com/pages/use-qr-codes-here?qr=OH5FKILNGWV3

DC to DC Battery Charger™ by Wagan Tech®
Thank you for purchasing the DC to DC Battery Charger™ by Wagan Tech®. With normal care and proper treatment, it will provide years of reliable service. Please read all  operating instructions carefully before use.
The 25A and 40A DC to DC Battery Chargers are designed to provide the optimal charging characteristics for your auxiliary battery from either your alternator or external  solar source. The solar controller is designed with Maximum Power Point Tracking (MPPT) to maximize the power coming from your solar panels up to the maximum rated  output. The DC to DC chargers also allow you to select either vehicle power or solar power priority and is programmable for all common types of automotive lead acid  batteries and LiFePO4 type starting batteries.

CAUTION

  • Do not charge a LiFePO4 battery when temperature is below 32ºF (0ºC).

  • Do not operate the battery charger unless you have read and understood this manual and the charger is installed as per these installation instructions.
    We recommend that the charger be installed by a qualified person.

  • The battery charger should not be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless  they are supervised or have been instructed on how to use the appliance by a person responsible for their safety.

  • Do not alter or disassemble the Battery Charger under any circumstances.

  • Only use the battery charger for charging 12V standard automotive lead acid, Gel, AGM, Calcium or LiFePO4 type batteries.

  • Check the manufacturer’s data for your battery to ensure that the maximum voltage of the profile you select as shown in the “Charge Control” section of this manual  does not exceed the manufacturer’s recommended max charging voltage. If the max voltage is too high for your battery type, please select another charging profile.

  • Check the mfg’s data for your battery to ensure that the “Continuous Current Rating” of the charger does not exceed the mfg’s recommended max charging current.

  • When using the Battery charger to charge a Lithium Iron Phosphate battery, only batteries that feature a built-in battery management system featuring built-in under and  over voltage protection and cell balancing are suitable. This charger is NOT compatible with other lithium ion or metal battery types.

  • The battery charger is not intended to supply power to a low voltage electrical system other than to charge a battery

  • Cable and fuse sizes are specified by various codes and standards which depend on the type of vehicle into which the Battery Charger is installed.
    Selecting the wrong cable or fuse size could result in harm to the installer or user and/or damage to the battery charger or other equipment installed in the system. The  installer is responsible for ensuring that the correct cable and fuse sizes are used when installing this Battery Charger.

  • Never smoke or allow a spark or flame in the vicinity of the battery or engine. this may cause the battery to explode.

  • To assist with the safe operation and use of the Battery Charger when connected to the battery:

  • a) wear complete eye and clothing protection. Avoid touching eyes while working near a battery.

  • b) If battery acid contacts your skin or clothing, remove the affected clothing and wash the affected area of skin immediately with soap and water. If battery acid enters  your eye, immediately flood the eye with running cold water for at least 10 min and seek medical assistance immediately.
    WARNING: Risk of explosive gases: Working in the vicinity of a lead-acid battery is dangerous. Batteries generate explosive gases during normal operation. For this  reason, you must follow the instructions when installing and using the charger.

PRODUCT OVERVIEW

WAGAN 7410, 7411 DC to DC Battery Charger - Figure 1

INSTALLATION

Mounting
The Battery Charger is designed for a variety of installation environments, including chassis rail, engine cabin, and driver cabin. The Battery Charger uses advanced  technology so that the product can withstand extremely turbulent, wet, dusty, and muddy environments.
Install the Battery Charger as close to the auxiliary battery as possible and mount the unit securely with appropriate mounting screws.WAGAN 7410, 7411 DC
to DC Battery Charger - Figure 2

Wiring
The Battery Charger wire may be not long enough for installation. If you need to extend the wire, please check the below table for suggested wire sizes. You can choose wires  that are equal to or larger than this size.

| 25A DC to DC Battery Charger (7410)| 40A DC to DC Battery Charger (7411)
---|---|---
<16 ft (5m)
long| <32 ft (10m)
long| <16 ft (5m)
long| <32 ft (10m)
long
Input + (Yellow) Output + (Red) Ground (Black)| 10AWG| 8AWG| 8AWG| 6AWG
Ignition (Blue)| 20AWG| 20AWG| 20AWG| 20AWG

It is very important that all wire extensions are well connected, to ensure the stable and reliable operation of the product. For your convenience, butt splice connectors have  been provided. After a secure connection is made, use the heat shrinkable tubing or electrical tape to completely cover any exposed wiring to prevent a short to surrounding metal.
Notes:

  • Disconnect the negative battery cable (Earth) from the vehicle’s starting battery before installation.
  • If your vehicle has a fixed voltage or temperature compensating alternator (standard alternators) installed, leave the Ignition Override cable (BLUE color) open. If your  vehicle has a smart (variable voltage) alternator installed, the Ignition Override cable must be connected to the vehicle’s ignition. The Battery Charger will only operate  when the vehicle’s ignition is turned on.
Input Turn On Turn Off
12V Standard Alternator >13.1V <12.8V
24V Standard Alternator >26.2V <25.6V
12V Smart Alternator >12.0V <11.8V
24V Smart Alternator >24.0V <23.6V
  • Do not re-connect the negative connection of the battery until all other connections are secure and insulated.

WAGAN 7410, 7411 DC to DC Battery Charger - Figure 3

Fuse Specification

All recommended fuses should be connected in series in circuit. Bolt down fuses are preferred because they ensure a low resistance connection. Blade- type fuses are not recommended as they can result in a high resistance connection which causes excess heat and may damage the fuse holder and/or the wiring. Selfresetting circuit breakers are not recommended as they may trip prematurely due to the heat generated by the current flowing through the wires.

Input + (Yellow)
Output + (Red)| 25A DC to DC Battery Charger (7410) — 40A fuse
40A DC to DC Battery Charger (7411) — 60A fuse
---|---
Ignition (Blue)| 3A fuse
Solar Input (Green)| 25A DC to DC Battery Charger (7410) — 40A fuse
40A DC to DC Battery Charger (7411) — 60A fuse

TYPICAL SETUP

WAGAN 7410, 7411 DC to DC Battery Charger - Figure 4

OPERATION

WAGAN 7410, 7411 DC to DC Battery Charger - Figure 5

Selecting Battery Type
Long Press the Mode button to select the battery type. There are 5 battery chemistries available: Standard Lead Acid, Gel, AGM, Calcium and LiFePO4.
Keep pressing the button momentarily until the Battery Chemistry LED you want is flashing. After you release the button, your selection is entered and saved. Your selection  will be restored automatically even after the Battery Charger is fully disconnected and reconnected. The default Battery Chemistry is STD.
Solar Priority Mode
Press the Solar Priority button to prioritize input from the solar panel over charging from the alternator. The solar priority LED will light up when selected.
LED Charge Indicator
You can tell which Charging Stage the battery is in by how fast the Alternator and/or Solar charge LEDs are flashing.
Short flash = Bulk or Absorption charging stage
Long flash = Float charging stage
Fault Indicator LEDs
Problems with the operation of the Battery Charger are indicated by the Fault
LED and/or a combination of solid or flashing Alternator, Solar, and Battery Type
LEDs. Use this chart to troubleshoot the problem:

Alternator LED| Solar LED| Battery Type LED| Fault LED| Trouble| Solution
---|---|---|---|---|---
Flashing Green| Off| Flashing Green| Off| Low voltage detected at Alternator input| Check battery voltage
Off| Flashing
Green| Flashing
Green| Off| Low voltage detected at
Solar input| solar voltage
Flashing
Green| Flashing
Green| Flashing
Green| Off| Low voltage detected at Alternator or Solar input| Check voltage of both alternator and solar panel
Flashing Green| Off| Off| Flashing Red| High voltage detected at Alternator input| Check battery voltage
Alternator LED| Solar LED| Battery Type LED| Fault LED| Trouble| Solution
---|---|---|---|---|---
Off| Flashing
Green| Off| Flashing Red| ge  H. et igh ec votedltaat
a
Solar input| Check solar voltage
Off| Off| Off| Flashing Red| Over temperature| Let the unit cool down
for some time or get better ventilation
Off| Off| Flashing
Green| Flashing Red| High voltage detected at output| Check the
battery
voltage

FEATURES

The Battery Charger is specifically designed for charging auxiliary batteries. It includes all the features needed to maintain an auxiliary battery at its optimum condition and to  prolong battery life.
Superior 3-Stage Charging
Using a high speed microcontroller and proprietary charging algorithm, the Battery Charger delivers a sophisticated 3-stage charging process resulting in a faster and more  powerful charge, ideal for deep cycle batteries. The first stage, bulk (constant current), charges the battery faster while the second stage, absorption (constant voltage),  ensures  the battery is thoroughly charged. The final stage, float, maintains the battery at a safe voltage, allowing it to be maintained and ready for use indefinitely.

Charging Process

WAGAN 7410, 7411 DC to DC Battery Charger - Figure 6

Solar Priority
The Solar Priority function allows for you to prioritize solar charging over charging from your alternator. As long as the solar panels produce more than 25W (for 7410) or  50W (for 7411) of power, the unit will select charging by solar. If the auxiliary battery decreases below a certain level, the unit will charge by alternator regardless of solar input.
Solar MPPT Optimized Charging
The Battery Charger utilizes sophisticated MPPT (Maximum Power Point Tracking) solar regulator technology. MPPT maximizes the power generated from the solar panels  to the auxiliary battery. The maximum power point tracking efficiency is up to 95%, creating a maximum charging current of 25A/40A.
Remote Monitor (Optional)
An external remote monitor (Part. No. 7400) is available to show the status of the charger. It shows how the auxiliary battery is charged by the alternator or the solar panel,  and other useful information.
SAFETY PROTECTIONS
Spark-Free Protection
The Battery Charger will not start charging the battery (no output) unless the load is securely connected (except the LiFePO4
mode which allows 0 volt start). It
prevents the output leads from sparking due to accidental short circuit making the charger safer to use around batteries.
Reverse Connection Protection
Reverse connection on input and output terminals does not damage Battery Charger internal circuit. The Battery Charger will not charge if output connections are reversed.
Over and Under Voltage Protection
The charger will automatically shut down if there is an over voltage or under voltage problem.
Over Temperature Protection
The charger will lower its output current if the temperature of the unit begins to overheat.

SPECIFICATIONS

Operating Conditions

Model| 25A DC to DC Battery
Charger (7410)| 40A DC to DC Battery
Charger (7411)
---|---|---
Input Voltage| 9-32V DC
Maximum Input Current| 25A| 45A
Back Drain on Auxiliary Battery| < 15mA
Output Current:| 25A| 40A
Input Fuse Rating| 40A (Not included)| 60A (Not included)
Output Fuse Rating| 40A (Not included)| 60A (Not included)
Maximum Output Power| 300W| 500W
IP Rating| IP66
Size| 1.7 x 5.1 x5.7 in.
(4.3 x 12.9 x
14.5 cm)| 1.7 x 5.1 x7.3 in.
(4.3 x 12.9 x
18.5 cm)
Weight| 1.4 lbs (0.63 kg)| 2.0 lbs (0.89 kg)

Charge Control

Charge Type 3-Stage
Charging Profile STD
Maximum Voltage 14.4V
Float Voltage 13.4V

Battery Range

Battery Capacity 50-500Ah, 80-800Ah
Type of Batteries Supported STD, GEL, AGM, Calcium, LiFePO,

WAGAN Corp. Limited Warranty

The WAGAN Corporation warranty is limited to products sold only in the United States.
Warranty Duration:
Product is warranted to the original purchaser for a period of two (2) years from the original purchase date, to be free of defects in material and workmanship.
WAGAN Corporation disclaims any liability for consequential damages. In no event will WAGAN Corporation be responsible for any amount of damages beyond the amount paid for the product at retail.
Warranty Performance:
During the warranty period, a product with a defect will be replaced with a comparable model when the product is returned to WAGAN Corporation with an original store  receipt. WAGAN Corporation will, at its discretion, replace or repair the defective part. The replacement product will be warranted for the balance of the original warranty  period. This warranty does not extend to any units which have been used in violation of written instructions furnished.
Warranty Disclaimers:
This warranty is in lieu of all warranties expressed or implied and no representative or person is authorized to assume any other liability in connection with the sale of our products. There shall be no claims for defects or failure of performance or product failure under any theory of tort, contract or commercial law including,but not limited to  negligence, gross negligence, strict liability, breach of warranty, and breach of contract.
Returns:
WAGAN Corporation is not responsible for any item(s) returned without an official Return Authorization number (RA#). Please contact our customer service team by phone or email to obtain an RA#. You can also visit our website and chat with our team during our normal business hours. For more details and instructions on how to  process a warranty claim, please read the “Returns” section under the “Contact” page on our website. WAGAN Corporation is not responsible for any shipping charges  incurred in returning the item(s) back to the company for repair or replacement.

©2022 Wagan Corporation. All Rights Reserved.
Wagan Tech and wagan.com are trademarks of Wagan Corporation.

Documents / Resources

| WAGAN 7410, 7411 DC to DC Battery Charger [pdf] User Manual
25A 7410, 40A 7411, DC to DC Battery Charger, DC to DC Charger, Battery Charger, Charger, 7410 7411 DC to DC Battery Charger, 7410 DC to DC Battery Charger, 7411 DC to DC Battery Charger
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals