GASTEC GSP-501FT Automatic Air Sampling Pump User Guide

June 3, 2024
GASTEC

GASTEC GSP-501FT Automatic Air Sampling Pump

Compact, lightweight, and reliable automatic air sampling pump for GASTEC detector tubes and sorbent tubes

Quiet operation with low noise Large screen displaying suction flow rate, sampling time, and integrated volume simultaneously.

Automatic Air Sampling Pump

GSP-501FT

  • Flow range 50-500mL/min
  • 10-500mL/min is available when volume mode (When set to 10-49 mL/min, the intermittent operation is performed at 50mL/min)
  • Fixed flow function automatically regulates load changes
  • Flow rate, sampling time, and integrated volume are displayed on the same screen simultaneously
  • Automatic start enables sampling to begin after a preset time
  • 5 sampling settings can be saved with the program mode
  • Real-time flow volume and integrated flow volume are automatically corrected to the values for 20ºC(68ºF) or 25ºC(77ºF)

OVERVIEW

GASTEC=-GSP-501FT-Automatic-Air-Sampling-FIG-1

GASTEC=-GSP-501FT-Automatic-Air-Sampling-FIG-2

Set two AA alkaline batteries or AA nickel-metal hydride batteries.

Specifications

GASTEC=-GSP-501FT-Automatic-Air-Sampling-FIG-9

Intermittent Operation

When the instantaneous flow rate is set to 10 – 49mL/min in the Volume Mode,the intermittent operation is performed by sampling at an instantaneous flow rate of 50mL/min.

Example of Intermittent Operation

When the Volume Mode is selected and the flow rate is set to 10 mL/min and the set volume is 0.1L, after the sampling is started, the pump will pause for about 48 seconds after about 12 seconds of sampling at a flow rate of 50mL/min (samples until the sampled volume per minute reaches 10mL, then pauses). A sampling at a flow rate of 50 mL/min for about 12 seconds and pausing for about 48 seconds are repeated until the set volume of 0.1 L is reached, taking about 10 minutes.

(Example) Volume Mode
  • Flow rate: 10mL/min
  • Integrated volume: 0.1L

Repeat until the sample volume reaches 0.1L

If there is a sudden change in the gas concentration or if sampling is performed for a short period of time, the error of the sampling result may be large.

Options

  • Gas sampling pump tripod stand GSP-TRIPOD: Mount GSP-501FT to use at the desired height.
  • Belt loop pump holder GSP500FT-30: Case for personal exposure measurement.
  • Rubber caps DTP-2-20: Reusable rubber caps can be attached to the broken tip of the detector tubes as an extra precautionary safety measure. One (1) package contains 20 caps.
  • Protective cover for detector tube GSP300-14: Enables the detector tube to be securely set up for measuring and helps to avoid possible injury to the user as well as damage to the detector tube itself.
  • Sampling tube holder 730: Tube holder for personal exposure measurement.
  • Tripod mounting plate PLATE 2: 2 pumps can be mounted on the same tripod.

Sorbent tubes

Sorbent tubes are glass tubes filled with sorption agents such as activated charcoal or silica-gel and are used to adsorb toxic gases in various environments. Both ends of the tube are broken off and connected to a sampling pump for sample collection. The adsorbate is then extracted using a solvent and analyzed using gas chromatography.

GASTEC=-GSP-501FT-Automatic-Air-Sampling-FIG-10

Detector tubes for Automatic Air Sampling Pump

GASTEC=-GSP-501FT-Automatic-Air-Sampling-FIG-11 GASTEC=-GSP-501FT-Automatic-Air-Sampling-FIG-201

  • T: Temp Correction
  • H: Humidity Correction
  • +: Twin Tubes
  • Refrigerated Storage
  • Correction Factor

Specifications and appearance are subject to change without notice. Read and understand the instruction manuals completely before operating. The actual products may differ slightly from the pictures shown.

GASTEC CORPORATION

  • 8-8-6 Fukayanaka, Ayase-city, Kanagawa 252-1195, Japan
  • Tel: +81(0)467-79-3910
  • Fax: +81(0)467-79-3979
  • URL: https://www.gastec.co.jp/

CA23GSP501FTE1 22K1DP

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals