tecnoswitch CR435BI Wall Mounted Chronothermostat User Guide

June 3, 2024
tecnoswitch

CR435BI

Rev.0322

tecnoswitch CR435BI Wall Mounted Chronothermostat

Weekly wall-mounted chronothermostat

keep control

TECNO SWITCH srl
Via P. Leone Dehon, 99/105 · 76123 Andria (BT) ITALY
tel (+39) 0883 555323 · fax (+39) 0883 555323
tecnoswitch.com

Fig. 1

CR435BI - Fig. 1

Fig. 2

CR435BI - Fig. 2

A-A=83.5mm
A-B=60mm
C-C=60mm

Fig. 3a                                           Fig. 3b

CR435BI - Fig. 3a CR435BI - Fig. 3b

Fig. 4

CR435BI - Fig. 4

Fig. 5

CR435BI - Fig. 5

Menu: Copia
Prog: Incolla

Fig. 6                     Fig. 7                     Fig. 8 Fig. 9

Fig. 10                   Fig. 11                     Fig. 12 Fig. 13

PRODUCT DESCRIPTION AND TECHNICAL SPECIFICATIONS

CR435BI is a programmable thermostat with weekly programming compatible both in combination with devices with ON/OFF type control and for the remote control of modulating boilers exclusively with OPENTHERM type communication. Before using CR435BI in OPENTHERM mode, it is recommended to check its compatibility with the boiler: BUS communication protocols other than OPENTHERM could affect the correct operation of the system.
This product is manufactured according to the standards EN 60730-1, EN60730-2-9, EN60730-2-7, in compliance with the applicable EC directives and is entirely manufactured in Italy.
For the correct use of the device, it is recommended that you read this manual carefully and keep it for future reference.

OPENTHERM mode:

– Power supply: 2 non-polarized bus cables (OT connection to boiler)
– ErP classification (EU Reg. 811 / 2013- 813/2013): Class V; 3%
Relay ON/OFF mode:
– Power supply: 2x 1.5V LR6 AA type alkaline batteries
– Maximum contact capacity: 5A (1A) 250 Vac
Maximum ambient temperature: 50°C
Temperature display range: 0°C÷39°C
Temperature resolution: 0.1°C
Temperature regulation range: 5°C÷35°C
Temperature differential: 0.1°C to 2.0°C (standard: 0.2°C)
Temperature sensor: NTC 100KΩ@25°C
Protection rating: IP20
Insulation class: Type II (double insulation)
Type of action: 1B
Degree of pollution: 2
Software: class A
Resistance to heat and fire: Category D
Storage temperature: -25÷60°C
Rated impulse withstand voltage: 2.5kV
Wall mounting

INSTALLATION

ATTENTION!
It is recommended that the chronothermostat be installed in strict compliance with the safety standards and legal provisions in force. Before making any connections, make sure that the main switch has been disabled.
The manufacturer is not liable for improper use of the product.
Install the device away from heat sources and drafts, about 1.5m from the floor.
Open the device by pressing the tooth on the right side of the base (Fig 1-A), rotate the front to the left (Fig.1-B) and move it slightly (Fig.1-C) to release it. Remove the internal protection covering the terminals by unscrewing the two screws (Fig. 2-D) and turning the cover to the left.
Fix the base to the wall, using a horizontal (Fig.2, A-A, A-B) or vertical (Fig.2, C-C) center distance.
Select the position of the “jumpers” selectors both on the relay/OT board (Fig.3A) and on the display board (Fig.3B) for the type of operating mode desired (ON / OFF or Modulating), factory set on ON / OFF:
POS. A:ON / OFF relay operation (factory)
POS. B: OPENTHERM modulating operation
Thread the cables through the opening on the bottom and connect them to the terminal block intended for the type of op-eration selected according to the diagram (Fig.3A) then reposition the internal cover by screwing the two screws (Fig.2-D).

BATTERY REPLACEMENT

When the symbol flashes (batteries flat) they must be replaced. To open the device, proceed as indicated in the installation instructions (Fig.1 and Fig.4). Reassemble the cover on the base before carrying out any operation.

DESCRIPTION OF CONTROLS AND OPERATION (Fig. 5)

The commands consist of a ring with four positions identified by the arrows , a central OK key and four additional keys: Menu (Copy), Prog (Paste), Mode, Esc. Press the ring corresponding to the arrows to activate one button at a time. Press the OK button in the center. Use the arrow keys to change the time and temperature values or select options. The center OK button normally confirms the settings.

FIRST START-UP

At the time of first installation, the basic settings must be made. After making the electrical connections, insert the batteries inside the compartment (which must be kept if the ON/OFF mode is used).
When turned on, the device displays the factory-set parameters in sequence with a non-backlit display.
Press to set the operating mode (ON/OFF or OT), then OK
If the ON/OFF operating mode is confirmed,CR435B1 starts the display backlight function. This function is instead available in OPENTHERM mode only in combination with boilers compatible with this function.
Set the clock (Fig. 6)

  • Set the format 24H or 12H with , then OK (standard: 24H)
  • Set the time with , then OK.
  • Set the minutes with , then OK.
  • Set the day with   , then OK.

Once the basic settings have been completed, the device goes to OFF mode.

ATTENTION:
IF THE DEVICE HAS BEEN PREPARED FOR OPERATION IN OPENTHERM MODE, THE BATTERIES WILL NEED TO BE REMOVED AT THIS POINT, PROCEEDING AS DESCRIBED IN THE BATTERY REPLACEMENT CHAPTER.
Once reassembled, the device re-proposes only the clock setting (to be carried out as above) and at the end it switches to OFF mode.
At the first installation and during the boiler ignition and shutdown phase, a few seconds may elapse, necessary both to ensure correct modulation and for the correct acquisition of operating data.

OFF MODE (Fig.7)

The display shows OFF and the clock, the ANTIFREEZE function is active.
Press the Esc key to switch from OFF to active mode and vice versa.
Press the Mode button one or more times to switch from one active mode to another (Comfort Manual, Economy Manual, Automatic).

COMFORT / ECONOMY MANUAL MODE (Fig. 8)

In these modes, the device activates the system regardless of the time settings when the temperature detected in the environment is lower (WINTER mode) or higher (SUMMER mode) than the set temperature.
Press or to modify and store the temperature values(displayed at the top right):
MAN = Comfort temperature (standard: WINTER = 20.0°C / SUMMER = 24.0°C)
MAN ECO = Economy temperature (standard: WINTER = 16.0°C / SUMMER = 28°C)

AUTOMATIC MODE (Fig. 9)

The temperature can be set on three different temperature levels: T1 (Comfort), T2 (intermediate) T3 (reduced) for minimum periods of half an hour during the day and changes automatically during the day according to the memorized time program.

TIME PROGRAMMING (Fig. 10)

Make sure that the clock setting is correct and that the device is in AUTO mode.

  • Press the Prog button to access the hourly programming function: the temperature set at the current half hour appears, with the wording PROG and the digital rider flashing.
  • Press the OK button one or more times to set the desired temperature for that half hour by choosing between T1 (Comfort temperature), T2 (Intermediate temperature) or T3 (Reduced-economy temperature).
  • Press    to move to the previous or next hours and, if necessary, change (as above) the settings displayed for T1, T2 and T3, until the end of the day.
  • Press to select another day of the week (1 = Monday, 7 = Sunday) and set (as above) the desired temperatures T1, T2 and T3 for the different time bands of each day.

To duplicate a daily program, select the day to copy, press the MENU key (COPY function) then move to the desired day and press the PROG key (PASTE function).
It is possible to modify the duplicated program to change the desired temperature settings T1, T2 or T3 (using the central OK button) by one or more periods (selected by moving with the    buttons).
To view / modify the values of the set temperatures, T1, T2 and T3

  • Press Mode to display (and if necessary modify with ) the value of T1
  • Press Mode to display (and if necessary modify with ) the value of T2
  • Press Mode to display (and if necessary modify with ) the value of T3

Press the Mode key once more to return to scheduling.
Once the settings have been completed, press the ESC key to exit the programming phase. The device acquires the set values and returns to the active AUTO mode of operation.

WINTER SEASON MODE

Comfort temperature T1 is higher than Economy temperature T3 (T1> T2> T3). When the room temperature (Tamb) is lower than the set temperature (Tset) the heating is activated.
(standard: T1 = 20.0°C, T2 = 18.0°C, T3 = 16.0°C).

SUMMER SEASON MODE (ON/OFF mode only)

The Comfort temperature T1 is lower than the Economy temperature T3 (T1 <T2 <T3). When the room temperature (Tamb) is higher than the set temperature (Tset), cooling is activated (standard: T1 = 24.0°C, T2 = 26.0°C, T3 = 28.0°C).

OPENTHERM MODE SETTINGS MENU (Fig. 11)

Press the Menu button to enter the settings menu.
Press    to scroll through the options and view the current set value.

  1. Press to set the Heating + DHW mode (Winter), DHW only (Summer), heating only.
  2. Press OK to set the clock (as the first switch on);
  3. Press to set degrees Celsius / Fahrenheit (standard: CELSIUS);
  4. Press to set the hot water set point for domestic use (standard 50.0°C);
  5. Press to set the hot water set-point for heating use (standard 60.0°C);
  6. Display of domestic hot water operating temperature;
  7. Heating hot water operating temperature display;
  8. Display of operating pressure of the heating system (bar);
  9. Visualization of the current modulation percentage of the boiler.

Press the ESC key to exit the menu and save the set data.

ON/OFF MODE SETTINGS MENU (Fig. 12)

Press the Menu button to enter the settings menu.
Press    to scroll through the options and view the current set value.

  1. Press to set the Summer / Winter season mode (standard: WINTER)
  2. Press OK to set the clock (as the first switch on);
  3. Press to set degrees Celsius / Fahrenheit (standard: CELSIUS);
  4. Press to change the brightness of the display backlight
    (Min / Max: 0-100% – standard: 50%).

Press the ESC key to exit the menu and save the set data.

INSTALLER MENU (Fig. 13)

In OFF mode, press OK for 10 seconds to enter the menu.
Press    to scroll through the options and view the current set value.

  1. Antifreeze = Press to modify the threshold value of the antifreeze function (Min / Max: 1.0 / 8.0°C – standard: 6.0°C);
  2. Hysteresis = Press to modify the intervention temperature differential value (Min / Max: 0.1 / 2.0°C – standard: 0.2°C);
  3. Calibration = Press to modify the correction value of the temperature detected by the device (Min / Max: -5.0 /+ 5.0°C – standard: 0.0°C);
  4. Press to change the operating mode (ON/OFF or OPENTHERM);
  5. Factory reset. Confirm with the OK key until automatic reset.

Press the ESC key to exit the menu and save the set data.

ALARMS AND MALFUNCTIONS (OPENTHERM MODE)

In the event of an alarm / system malfunction, the generic abbreviation ‘Alr’ will appear on the CR435BI display.
To reset, refer to the boiler instruction manual or to the relevant Assistance Center after having identified any alarms or codes present on the boiler panel.
In the event of a power failure, the CR435BI clock resets, it is therefore necessary to reset the time and day of the device, the other parameters such as the weekly schedule and the various set points are kept in the memory.
Following the reset, in the event of a prolonged lack of clock setting (after 30 minutes), CR435BI goes into MANUAL COMFORT ECO mode, the device display shows the flashing time with the fixed characters ’00:00′.