tecnoswitch UM100BG Electronic Recessed Humidistat User Guide
- June 1, 2024
- tecnoswitch
Table of Contents
tecnoswitch UM100BG Electronic Recessed Humidistat
WARNINGS BEFORE INSTALLATION
- The device must be installed by qualified personnel.
- The device must be positioned about 1.5 meters above the floor, avoiding heat sources, windows and doors.
- Humidistat must be installed in three modules recessed boxes type 503E.
- Two interchangeable faceplates are supplied, white and charcoal grey.
- The white front panel is pre-installed. If you want to change the colour, follow the procedure described in the paragraph ‘FRONT PANEL REPLACEMENT’.
- Inserting the batteries incorrectly could damage the device.
TECHNICAL SPECS
- Power supply 2 AA batteries (alkaline)
- Relay type 1 changeover dry contact NO/NC
- Max relay load 8(5)A – 250Vac
- Relative humidity adjusting range from 30 to 90%
- Reading tolerance RH +3%
- Humidity reading interval every 10 seconds
INSTALLATION
- Choose faceplates to use.
- Remove the humidistat from its casing using the pull tab and remove the battery cover at the bottom of the appliance with a flat head screwdriver Fig.1.
- Insert 2 batteries AA alkaline 1.5 V, respecting the polarity indicated on the bottom and reassemble the battery cover.
- Choose among the 4 universal supports supplied the one compatible with the plate in possession (SEE SUPPORT INSTRUCTIONS) and install the humidistat following the order indicated in Fig.2.
FRONT PANEL REPLACEMENT
The device comes with a factory-installed white faceplate. To replace it with a different colour, proceed as follows:
- Turn 1he knob on 30% and make sure the switch is ON.
- Unhook the front panel, so also the knob, from the device by prying with a flat head screwdriver in the two side slots on the right side (Tecnoswitch logo side) and remove it from the device.
- Remove the pull-out tab (down to the right) by pulling it out first, then turn it down to pull it out of its housing. Then assemble the extraction tab of different color, following the procedure inverse to that of disassembly.
- Align the right part of the front panel of different color to the side hooks and the pull-out tab and press on the left side 10 lit it. Place 1he knob indicator at the 30% value and press on the knob until it beats.
ELECTRICAL CONNECTIONS
After inserting the batteries, connect the wiring of dehumidification (or humidification) system to the screw terminals on 1he back of 1he device following 1he diagrams in Fig.3A or Fig.3B
OPERATION
By setting the desired relative humidity threshold using the knob, the device will activate the dehumidification (or humiditication) system when the ambient relative humidity exceeds the set threshold in order to keep the desired value constant.
The SW switch allows you to:
- Turn the device on by positioning it to the left 0111.
- Turn off the device by positioning it to the right OFF.
- NOTE : Placing the switch in the middle position (not printed) turns the device off.
HUMIDITY THRESHOLD ADJUSTMENT
Use the knob to set the desired relative humidity 1hreshold, with a range from
30 to 90% When the relay contact is closed and thus the
dehumidification/humidification system is in operation, LED indicator l2
(load) Hashes red every 5 seconds.
BATTERY CHARGE CHECK
Press the button T1 (test)
- if the led indicator (L1) light up, batteries are charged.
- if the led indicator (L1) is off, batteries are low. You have to replace it.
Tecno Switch reserves the right to make changes to its products in each moment and without further notice. Tecno Switch declines all responsibility for damage to things or persons derived from an incorrect or improper use of its products. For more information consult our website tecnoswitch.com
Documents / Resources
|
tecnoswitch UM100BG Electronic Recessed
Humidistat
[pdf] User Guide
UM100BG, UM100BG Electronic Recessed Humidistat, Electronic Recessed
Humidistat, Recessed Humidistat, Humidistat
---|---