ancona AN-17016BSS Wall Range Hood User Manual

June 3, 2024
ancona

ancona AN-17016BSS Wall Range Hood User Manual
ancona AN-17016BSS Wall Range Hood

Before You Begin

INSTALLERS- Start Here

Safety Instructions are on pages 4 and 5 and Installation Instructions are on pages 9 to 15.

Please perform these steps:

  1. Read the safety instructions.
  2. Read all instructions in the Installation section of this manual BEFORE installing the range hood.
  3. Remove all packing materials.
  4. When finished, make sure to leave these instructions with the consumer.
  5. Installation is to be done by a qualified technician only. However, the ultimate responsibility for proper installation falls to the owner.
  6. Product failure due to improper installation is not covered under the Warranty.
CONSUMERS – Start Here

Safety Instructions are on pages 4 and 5 and Operating Instructions are on pages 15, 16 and 19.

Please perform these steps:

  1. Read the safety instructions.
  2. Read all instructions in the manual BEFORE operating the range hood.
  3. Remove all packing materials.
  4. Installation is to be done by a qualified technician only. However, the ultimate responsibility for proper installation falls to the owner.
  5. Product failure due to improper installation is not covered under the Warranty.

Hardware Note: For safety reasons, range hood mounting screws and anchors will not be included due to the variation of cabinetry constructions and wall material.
Please consult your installation specialist regarding the optimal type of mounting screws and wall anchors to suit your home’s construction.

Important Safety Information

READ ALL INSTRUCTIONS BEFORE USE

Read and follow all instructions before using the range hood to prevent the risk of fire, electric shock, personal injury, or damage when using the range hood or appliances with the range hood.
This guide does not cover all possible conditions that may occur. Always contact your service technician or manufacturer about problems that you do not understand.

  • The installation in this manual is intended for qualified installers, service technicians or persons with a similar qualified background.
    Installation must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction.

  • The range hood may have very sharp edges; please wear protective gloves if it is necessary to remove any parts for installing, cleaning or servicing.

  • Activating any switch to ON position before completing installation may cause damage or electric shock.

  • Due to the size of this range hood, a two person installation is recommended.

To reduce the risk of fire, electric shock, or injury to persons:

  • For general ventilating use only. DO NOT use to exhaust hazardous or explosive materials and vapors.

  • WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.

  • The combustion air flow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and other local code authorities.

  • Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
    When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

  • Clean grease-laden surfaces frequently.
    To optimize performance and to disperse air properly, make sure to vent air outside.

  • DO NOT vent exhaust into spaces between walls, crawl spaces, ceilings, attics or garages.

  • Ducted fans MUST always be vented to the outdoors.

  • This unit MUST be grounded and used with metal ductwork only.

  • Sufficient air is needed for proper combustion and exhausting of gases through the duct to prevent back drafting.

  • When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities.

  • All electrical wiring must be properly installed, insulated and grounded.

  • Old ductwork should be cleaned or replaced if necessary to avoid the possibility of a grease fire.

  • Check all joints on ductwork to ensure proper connection; all joints should be properly taped using a certified aluminum or foil tape.

  • Use this unit only in the manner intended by the manufacturer. If you have questions, contact the vendor.

READ AND SAVE THESE INSTRUCTIONS

WARNING: TO REDUCE RISK OF A RANGE TOP GREASE FIRE:

  • Never leave surface units unattended at high settings. Boil overs cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

  • Always turn range hood ON when cooking at high heat or when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, etc.).

  • Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
    Before servicing or cleaning unit, unplug and disconnect the hood from the power supply.

  • Use proper pan size. Always use cookware appropriate for the size of the surface element.

**WARNING: TO REDUCE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING ***

  • SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
  • NEVER PICK UP A FLAMING PAN – You may be burned.
  • DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.
  • Use an extinguisher ONLY if:
  1. You know you have a Class A, B, C extinguisher, and you already know how to operate it.
  2. The fire is small and contained in the area where it is started.
  3. The fire department is being called.
  4. You can fight the fire with your back to an exit. * Based on “Kitchen Fire Safety Tips” published by NFPA

To reduce the risk of injury to persons in the event of a gas leaks

  • Extinguish any open flame.
  • DO NOT turn on the lights or any type of appliance.
  • Open all doors and windows to disperse the gas. If you still smell gas, call the gas company and fire department.

Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. All safety messages outline any potential hazards, how to reduce the chance of injury, and possible risks if the instructions are not followed.

Included Parts

Hardware Note: For safety reasons, range hood mounting screws and anchors will not be included due to the variation of cabinetry constructions and wall material. Please consult your installation specialist regarding the optimal type of mounting screws and wall anchors to suit your home’s construction.

  1. Main Housing
    Included Parts

  2. Lower Chimney

  3. Upper Chimney

  4. Damper

  5. Upper Chimney Bracket
    Included Parts

  6. Lower Chimney BracketIncluded Parts

  7. Hood Mounting Bracket
    Included Parts

  8. Filters ×2 (30”) Filters ×3 (36”)

  9. 4 + 1 Screws (C) 4 + 1 Screws (D)

Range Hood Dimensions

Dimensions

Specification

Body Design Stainless Steel
Power Rating 120 V / 60 Hz (cETLus
Total Input Power 236 W (230 W + 2 × 2.55 W)
Motor Input Power 230 W
Amperage 1.96 A
Speed Control Levels 3 Speeds
Interference Protection Radio Frequency Interference Protected
Motors Single Motor
Control Electronic control panel
Illumination 2 × 2.55 W LED
Fan Type Single chamber quiet
Venting Size Top, 6 inches (153 mm) round
Mounting Brackets
  • Upper Chimney Bracket
    Mounting Brackets

  • Lower Chimney Bracket
    Mounting Brackets

  • Mounting Bracket Hook
    Mounting Brackets

Installation

STEP 1
Read the Safety Instructions

  • It is very important to read the safety instructions on pages 4 and 5.

IMPORTANT: It is the installer’s responsibility to comply with installation clearances.

STEP 2
Unpack Range Hood and Prepare Tools

  • Carefully unpack the range hood and parts. Make sure all parts are included as shown on page 6.
  • DO NOT remove the protective film covering the appliance until the installation is fully completed.
  • Consult a qualified and trained installer or check local codes for makeup air requirement, if any

STEP 3
Plan Desired Location

  • Plan a desirable location that fits all requirements in the Safety and Installation sections of this manual. Plan where and how the ductwork will be installed.

  • A straight or short duct run will allow the unit to perform most efficiently. Long duct runs, elbows and transitions will reduce the performance of the unit. Each elbow is equivalent to 5 to 10 feet (1.5 m to 3 m) of straight run.
    Proper size duct work should be 6 in. (15.3 cm) in diameter.

  • To reach a 9 foot (2.74 m) ceiling make sure hood is installed 30 inches (76.2 cm) from cooking surface. If you have a ceiling greater than 9 ft (2.74 m), please visit anconahome.com to order a chimney extension.

  • If ductwork is already installed: ensure ductwork is free from debris and measures 6 in. (15.3 cm) (1 in. (2.5 cm) reducers may be used but more than 1 in. (2.5 cm) will overwork the motor and the unit will not function properly).

STEP 4
Test Unit Functions

  • Plug the unit in and test all of the functions before installing.
  • Place the range hood on a flat, stable surface. Connect the range hood to a designated standard outlet (120-Volt, 60Hz, AC only) and turn on the range hood. Verify all operations of the range hood by referring to Range Hood Operations.
  • Turn power On in control panel.
  • Check all lights and fan operations

WARNINGS:

  • Please make sure to read ALL safety instructions on pages 4 and 5.
  • Use two or more people to move and install range hood.
  • Failure to follow these instructions can result in serious injury.

STEP 5
Venting Installation Guidelines

  • The following steps are for exterior ventilation.
  • If you require a ductless installation, please visit anconahome.com to purchase a recirculation kit.

IMPORTANT:

  • Vent system must terminate to the outside (roof or side wall).
  • DO NOT terminate the vent system in an attic or other enclosed area.
  • DO NOT use 4 in. (10.2 cm) laundry-type wall caps.
  • Use metal/aluminum vent only. A rigid metal/aluminum vent is recommended.
  • DO NOT use a plastic vent.
  • Always keep the duct clean to ensure proper airflow.
  • Calculate the following figures before installation:
    1. Distance from the floor to the ceiling
    2. Distance between the floor and the countertop/stove
    3. A distance of 24 in. to 30 in. (61 cm to 76.2 cm) is recommended between stove top and the bottom of range hood. 30 in. (76.2 cm) minimum is required for gas stove tops.
    4. Height of hood and duct cover

For the most efficient and quiet operation:

  • It is recommended that the range hood be vented vertically through the roof through 6 in. (15.3 cm) or bigger round metal/aluminum vent work.
  • The size of the vent should be uniform.
  • Use no more than three 90° elbows.
  • Make sure there is a minimum of 24 in. (61 cm) of straight vent between the elbows if more than one elbow is used.
  • DO NOT install two elbows together.
  • The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.
  • The vent system must have a damper. If roof or wall cap has a damper, you may remove damper flaps from damper to increase air flow.
  • Only one flange is needed in the air duct system, either on top of the motor or outside.
  • Use silver tape or duct tape to seal all joints in the vent system.
  • Use caulking to seal exterior wall or roof opening around the cap.
Height and Clearance

Height and Clearance

IMPORTANT:

  • A minimum of 6 in. (15.3 cm) round or 3-1/4 × 10 in. (8.3 cm × 25.4 cm) rectangular duct (purchased separately) must be used to maintain maximum airflow efficiency.
  • Always use rigid type metal/aluminum ducts if available to maximize airflow when connecting to provided duct.
  • Please use Duct Run Calculation below to compute total available duct run when using elbows, transitions and caps.
  • ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increase duct size from 6 in. (15.3 cm) to 7 in. (17.7 cm) or 8 in. (20.3 cm). If a reducer is used, install a long reducer instead of a pancake reducer. Reducing duct size will restrict airflow and decrease airflow, thus reduce duct size as far away from opening as possible.
  • If turns or transitions are required, install as far away from opening and as far apart, between two (2), as possible.
  • Minimum mount height between stove top to hood bottom should be no less than 24-inch (61 cm) for electric cook tops and minimum of 30-inch (76.2 cm) for gas stove tops and no higher than 30-inch (76.2 cm) for electric cook tops.
  • It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high may be hard to reach and will lose its performance and efficiency.
  • If available, also refer to stove top manufacturer’s height clearance requirements and recommended hood mounting height above range.
    Duct Run Calculation example:

Duct Run Calculation:

Recommended maximum run
6 in. (15.3 cm) or 3 1/4 x 10 in.

(8.3 x 25.4 cm) duct

| 30 ft

(9.1 m)

Vent piece deduction
Each 90° elbow used| 9 ft (2.7 m)
Each 45° elbow used| 5 ft (1.5 m)
Each 6 in. to 3-1/4 x 10 in.transition used| 7 ft (2.1 m)
Side wall cap with damper|  0 ft (0 m)

  • One roof cap, two 90º elbows, and one 45º elbow use. 0ft + 9ft + 9ft + 5ft = 23ft used.
  • Deduct 23ft from 30ft, 7ft maximum available for straight duct run.
  • This range hood is factory set for venting through the roof or wall.
  • Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.

IMPORTANT:

  • NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside
  • Use metal/aluminum duct work only.
  • Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape.
  • Use caulking to seal exterior wall or roof opening around the cap.
  • **TOP VENTING ROOF EXHAUS

**

  • TOP VENTING WALL EXHAUST

  • **RECIRCULATING MODE

**

STEP 6
Preparations
NOTE: To avoid damage to your hood, prevent debris from entering the vent opening.

  • Determine and mark the center line on the ceiling or wall where the range hood will be installed.
  • Make sure there is proper clearance within the ceiling or wall for exhaust vent.
  • Due to the weight and size of this unit, please make sure that the support system or framework being used is stable and secure in the ceiling or wall.
  • Put a thick, protective covering over counter top, cook top or range to protect from damage or dirt.
  • Remove any hazardous objects around the area when installing.

CAUTION:
If moving the cooking range is necessary to install the hood, turn OFF the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE

STEP 7
Installing the Hood Mounting Bracket

  • Use a pencil to mark on the wall the desired placement of the range hood mounting screws.
  • The range hood will be installed on top of this bracket (see   Figure 1).
  • Using references in Height & Clearance on Page 10 and Measurements and Diagrams on Page 7, drill 3 holes that will be used to fix the lower mounting bracket.
    Installation Instruction

STEP 8
Installing the Upper Chimney Bracket

  • Drill 2 holes according to the size of the upper mounting bracket. The upper mounting bracket should be positioned with the top of the outside chimney (see Figure 1).
  • Screw upper and hood mounting brackets in tightly

STEP 9
Venting

  • Fix the damper on the top vent of hood with 4 screws (C) (see Figure 2).
  • If ventilation system is equipped with an external air duct with a different diameter, apply a reduction fitting. However, for maximum performance and safety, a 6 in. round ducting is recommended.

STEP 10
Mount Range Hood onto Wall

  • Hang the range hood on the hooks of the lower mounting bracket (see Figure 3).
  • Screw the range hood to the wall.
    CAUTION:  Make certain the range hood is secure before releasing!
    Installation Instruction

STEP 11
Connect Ductwork

  • Attach ductwork to damper. Secure the ductwork with duct tape to make sure joints are secure and air-tight.
  • Do not install the duct tape too tightly as this may prevent the damper from opening which will overwork the motor and cause improper functioning of the unit.
  • Fasten all connection with sheet metal screws and tape all joints with certified aluminum or foil tape. Use caulking to seal exterior wall or roof opening around the cap.

STEP 12
Install Chimney

  • Place chimney on top of the main housing.

  • Remove the protective coating from the upper chimney. Carefully slide the upper chimney down into the lower chimney.
    Make sure upper chimney is moving freely.

  • Use two (2) screws (D) to fix lower chimney to range hood **(Figure 4)

**

  • Hook lower chimney bracket to lower chimney (see Figure 5).

  • Screw lower mounting bracket onto wall.

  • Screw the upper chimney to the upper mounting bracket (screw D) (see Figure 6).
    Installation Instruction

STEP 13
Connect to AC

  • Connect AC plug into a grounded AC outlet having 120V, 60Hz. Place the outlet at a maximum distance of 33-1/2” (851 mm) from where the cord exits on the hood.
  • SEE IMPORTANT INSTRUCTIONS ON THIS PAG
    Installation Instruction

IMPORTANT:

  • Observe all governing codes and ordinances.
  • It is the customer’s responsibility to contact a qualified electrical installer.
  • If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. A 120-Volt, 60 Hz, AC-only, fused electrical supply is required on a separate 15-amp circuit, fused on both sides of the line.
  • DO NOT ground to a gas pipe.
  • Check with a qualified electrician if you are not sure that the range hood is properly grounded.
  • DO NOT have a fuse in the neutral or ground circuit.
    IMPORTANT: Save this Installation Guide for electrical inspector’s use.

GROUNDING INSTRUCTIONS:

  • This appliance must be grounded. In the event of an electrical short-circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current.

  • This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
    WARNING: Improper grounding can result in a risk of electric shock.

  • Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. DO NOT use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.

STEP 14
Install Filters
To Install filters follow the steps below (see figure 7.)

  • Angle the filter into slots at the back of the hood.
  • Push the button on handle of the filter.
  • Release the handle once the filter fits into a resting position.
  • Repeat to install all filters.
    Installation Instruction

Operation

  • **Low Speed

**

  • **Medium Speed

**

  • **High Speed

**

  • Light

Power Settings

  1. Press the button  once and the motor starts to operate at Low speed.
  2. Press the button  and the motor will reach Medium speed.
  3. Press the button  the motor will reach High speed.

Lights

  1. Press the light button  to turn LED lights on and off.

Maintenance

Replacing the Light Bulbs

IMPORTANT:
ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY AT THE MAIN PANEL BEFORE CARRYING OUT ANY OPERATION ON THE APPLIANCE.

  1. Make sure the range hood is unplugged or turn OFF breaker.

  2. Open the filter and find the spring of the light.

  3. Push the spring and the lights will slip out.
    CAUTION: BULB MAY BE HOT, PLEASE TAKE OUT THE BULB WHEN THE BULB IS COMPLETELY COOL!

  4. Replace with a 10.2 Volt, 2.55 Watt max, LED lights.
    Do not touch replacement bulb with bare hands!

  5. Turn ON breaker and range hood to test for operation.
    Maintenance

Cleaning Filters

IMPORTANT: Drain oil from spacers, filters, oil tunnels, oil containers before oil and residue overflow!

  • Remove all spacers, filters, grease tray, and oil containers and discard oil and residue.
  • Wash with warm soapy water. NOTE: Stainless steel filters, spacers and oil tunnel are top rack dishwasher safe.
  • Dry thoroughly before replacing and follow directions for installation in reverse.
  • Filters should be cleaned after every 30 hours of use.
  • Should filters wear out due to age and prolonged use, replace with a new filter.
Range Hood Assembly

Assembly
Assembly

Number Part
1 Filter
2 Blower assembly
3 Electrical box cover
4 PCB of mechanical switch
5 Electrical box base
6 Bracket of electrical box
7 Front panel
8 LED puck lights
9 Electronic switch box
10 Electronic switch box cover
11 Electronic switch board
12 Electronic switch
13 Electronic switch box bracket
14 Stainless steel frame
15 Body assembly
16 Power cord
17 Hook plate
18 Metal outlet
19 Lower chimney
20 Lower chimney bracket
21 Upper chimney
22 Upper chimney bracket
23 Lamp guide wire
24 Switch guide wire

Circuit Diagram

Assembly Instruction

Blower Assembly

Assembly Instruction

Number Part
1 Blower
2 Wind Wheel Nut
3 Wind Wheel
4 Motor
5 Incabloc Rubber
6 Aluminum Cover
7 Plastic Wind Net
8 Sealing Gasket

Electrical Assembly

Assembly Instruction

Number Part
1 Electrical Box Bracket
2 Electrical Box Base
3 PCB
4 Capacitor
5 Electrical Box Cover

Use and Care Information

Operations
  • Read and understand all instructions and warnings in this manual before operating the appliance. Save these instructions for future reference.
  • Always leave safety grills and filters in place. Without these components, operating fans could catch on to hair, fingers and loose clothing.
  • NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into fans.
  • NEVER leave cooking unattended. When frying, oil in the pan can easily overheat and catch fire. The risk of self combustion is higher when the oil has been used several times.
  • NEVER cook on “open” flames under the range hood. Check deep-fryers during use; superheated oil may be flammable.
Cleaning
  • The saturation of greasy residue in the fan and filters may cause increased inflammability. Keep unit clean and free of grease and residue build-up at all times to prevent possible fires.
  • Filters must be cleaned periodically and free from accumulation of cooking residue (see Cleaning Instructions below). Old and worn filters must be replaced immediately.
  • DO NOT operate fans when filters are removed. Never disassemble parts to clean without proper instructions.
    Disassembly is recommended to be performed by qualified personnel only. Read and understand all instructions and warnings in this manual before proceeding.

SAFETY WARNING: Never put your hand into area housing the fan while the fan is operating!
For optimal operation, clean range hood and all baffle/spacer/filter/grease tray/oil container regularly. Regular care will help preserve the appearance of the range hood.

Cleaning Exterior Surfaces
  • Clean periodically with hot soapy water and clean cotton cloth. DO NOT use corrosive or abrasive detergent (e.g. Comet Power Scrub®, EZ-Off® oven cleaner), or steel wool/scoring pads, which will scratch and damage the stainless steel surface. For heavier soil use liquid degrease such as “Formula 409®” or “Fantastic®” brand cleaner.

  • If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface of the hood. Avoid getting cleaning solution onto or into the control panel. Follow directions of the stainless steel cleaner.
    CAUTION: DO NOT leave on too long as this may cause damage to hood finish. Use soft towel to wipe off the cleaning solution, gently rub off any stubborn spots. Use dry soft towel to dry the hood.

  • After cleaning, you may use non abrasive stainless steel polish such as 3M® or ZEP®, to polish and buff out the stainless luster and grain. Always scrub lightly, with clean cotton cloth, and with the grain.

  • DO NOT allow deposits to accumulate or remain on the hood.

  • DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface and cause rusting.

  • DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals, which may be harmful.

  • Rinse with water after exposure to these compounds and wipe dry with a clean cloth.

Customer Support

Please register your product warranty by visiting the Ancona Home website.

Canada & USA
Fax: 800-350-8563
Email: service@anconahome.com
Website: www.anconahome.com
Ancona is in association with Mr Appliance for all after sales service calls.
Please contact their service provider or visit their website:
Phone: 888-998-2011
Website: www.mrappliance.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals