AIR AUTO SWING TEMP
FANSPEED
SLEEP POW ERFU L
AIRSWING
FANSPE ED
ACXF55-31900
This symbol shows that this equipment uses a flammable refrigerant. If the refrigerant is leaked, together with an external ignition source,there is a possibility of ignition.
Thank you for buying Panasonic
Air Conditioner
This symbol shows that the Operating Instructions should be read carefully.
This symbol shows that service personnel should be handling this equipment
with reference to the Technical Manual.
This symbol shows that there is information included in the Operating
Instructions and/or Installation Instructions.
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
1 SAFETY PRECAUTIONS
Please observe these following safety precautions when using your air conditioner. Failure or negligence in observing these safety precautions could cause fire, electrical shock or personal injury.
This sign warns of risk of death or serious injury.
This symbol (with a white background) denotes an action that is PROHIBITED.
This sign warns of risk of injury or damage to property.
These symbols (with a green background) denote actions that are COMPULSORY.
INSTALLATION PRECAUTION
Do not install, remove and reinstall the unit yourself. Improper installation may cause Leakage, electric shock or fire. Please engage an authorized dealer or specialist for the installation work. Do not add or replace refrigerant other than the specified type. It may cause product damage, burst and injury. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similar qualified persons in order to avoid hazard.
The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater)
In cases that require mechanical ventilation, ventilation openings shall be kept clear of obstruction.
Ventilate any enclosed areas when installing or testing the refrigeration system. Escaped refrigerant gas, on contact with fire or heat, can produce dangerously toxic gas.
Confirm after installation that no refrigerant gas is leaking. If the gas comes in contact with a burning stove, gas water heater, electric room heater or other heat source, it can cause the generation of toxic gas.
The room air conditioner must be earthed. Improper grounding could cause
electric shock.
Do not install the unit in a place where there are explosive gas leaks. Gas
leaks near the unit could cause fire.
Ensure that the drainage piping is connected properly. Otherwise water will
leak out.
R32
Risk of fire / Flammable materials
OPERATION PRECAUTION
This sign warns of risk of death or serious injury.
This sign warns of risk of injury or damage to property.
Do not modify the length of power cord or use an extension cord. Do not touch
or operate with wet hands. Do not modify or damage the cord. Do not turn on
the unit by inserting the power plug. Do not switch off the unit by pulling
out the power plug. Avoid an extended period of direct airflow. Do not Insert
your fingers or other objects into the unit, rotating parts may cause injury.
Do not try to repair the unit yourself.
Plug in properly before operating and use a specified power cord. If abnormal
conditions (burnt smell, etc.) occur, switch off and remove the power plug.
Confirm to authorized dealer or specialist on usage of specified refrigerant
type. Using of refrigerant other than the specified may cause product damage,
burst and injury etc. This appliance is not Intended for use by persons
(including children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that they do not play with the
appliance.
Do not use the unit for other purposes, than its intended use. Do not remove
the power plug by pulling the cord. Do not block the air intake and outlet
vanes. Do not splash or direct water at the unit. Do not expose the unit to
direct sunlight during operation. Do not operate the unit without the air
filter installed or when the front intake grille has been removed. Do not
place any objects on the unit. Do not operate any combustion equipment near
the unit’s air flow area. Do not sit or step on the unit, you may fall down
accidentally. Do not touch the sharp aluminium fin, sharp parts may cause
injury. Do not use means to accelerate the defrosting process or to clean,
other than those recommended by manufacturer.
Switch off the breaker and unplug the unit from the socket if the unit will
not be operated for a long period. Pay attention to any damages on the unit
caused by extensive usage. Ventilate the room occasionally where the unit is
installed. Unplug the power cord when cleaning the unit.
ABOUT THE BATTERIES
The batteries can be used for approximately one year. Be sure to replace the
batteries with two new identical batteries. Remove the batteries if the air
conditioner will not be used for an extended period of time.
OPERATION CONDITIONS
Use the air conditioner
under the following
Max. Temperature
conditions:
Min. Temperature NOTE:
Humidity may exceed 90%
Operating temperature range.
Indoor side D.B.T. W.B.T.
(unit in °C) Outdoor side D.B.T. W.B.T.
32
23
43
26
16
11
16
11
D.B.T.: Dry Bulb Temperature W.B.T.: Wet Bulb Temperature
Continuous operation at over 90% high humidity may create condensation and result in waterdrops on the intake and outlet vanes.
Avoid installation in the following locations. Mechanical processing plants
and other places with a lot of mechanical oil. High humidity areas such as
laundry room and bathroom.
Air conditioner normal operating temperature. In side maximum temperature 30
Out side maximum temperature 43
NOTICE: When the air conditioner is used at room temperature of 21 degrees or
less, the temperature may be too low, and the air conditioner may be easily
frosted. After frosting, it may be difficult to drain and may flow into the
room.
4 AIR CONDITIONER INSTALLATION
CHOOSING THE INSTALLATION LOCATION
When installing, use the nearest power outlet. Make sure the power outlet is
easy to reach so you can quickly disconnect your air conditioner in case of
emergency. Ensure that the air conditioner is well supported, securely
fastened, easily reachable and not obstructed. Aviod location with: salty or
sulphurous air, draughts, dampness and flammable gas. If you install the
drainage system, be sure to channel the concensed water to a suitable
location. Covers, obstructions and unsteady support may cause excessive
operating noise and vibration. The rear end of the air conditioner is splash
proof. You don’t need to shield or cover it. R32 refrigerant air conditioner
installation and maintenance should be done by competent person.
PREPARATIONS BEFORE INSTALLATION
Dimension
There should not be any obstacles surrounding the unit.
Prepare and installation hole slightly bigger than the cabinet size.
Left and right side of the unit should be at least 15 cm
away from the wall.
The minimum installation height is 75cm.
(Based on IEC 60335-2-40, there is no restriction for the minimum installation
indoor
floor area since the refrigerant charges is less than 1.224kg.
CAUTION POINT DURING INSTALLATION
When installing air conditioner at glass window or thin partition, fix the vertical and side supporting bar to the concrete wall in order to support the weight of the air-conditioner and reduce the vibration that is being transferred to the glass window or thin partition.
Over100cm
80cm outdoor
This can minimize the noise problem caused by improper installation.
Proposed to use 1/8″ x 1-1/4″ “angle-aluminium for installation frame and side
supporting bar.
INSTALLATION PROCEDURES
1
Remove the chassis locking bracket from the cabinet. Save for later use.
2 Slide the chassis out from the cabinet
Depending upon the location of AC outlet,
6 route the AC cord to either left or right side
before Installing the front grille.
Counter clockwise
Outdoor
Chassis locking bracket.
3 Place the cabinet into the installation hole.
This figure shows the AC cord routed to the left side.
7 Attach the front grille to the cabinet
and fasten it with a screw.
4 Slide the chassis into the cabinet.
5
Lock the chassis to the cabinet reusing the chassis locking bracket.
Insert front grille tabs into the cabinet slots
8 Attach air filter to the front
grille. (see anti-bacterial filter installation instructions included in this
package)
9 Position the intake grille horizontally and hook the front grille fulcrum
to the grille force arm.
10 Press down control panel and close the cover.
2 PARTS IDENTIFICATION
MAIN UNIT Air Inlet Louver
Cabinet
‘SPOU(SJMMF’VMDSVN
PEZ4VQQPSU
(SJMMF’PSDFBSN
Air Filter (behind the front intake grille)
Front Intake Grille
Touch Control Panel
Vertical airflow direction vane (Airflow direction adjustment up-down). The
vertical airflow direction vane is controlled by positioning the vent to
discharge the air upwards, downwards, or straight out.
Front Grille
Ventilation Lever The ventilation lever must be in CLOSE position in order to
maintain the best cooling conditions.When fresh air is necessary in the room,
set the ventilation lever to the Open position. The damper is opened and room
air is drawn out.(If the ventilation lever is OPEN, there is a chance that
noisy noise can be introduced into the room)
Touch Control Panel
TEMP ON/OFF
When the filter cleaning light flashes or brighten,it is recommended to clean the filter after dismantle.Filter cleaning light will flashes about 20
second,if didn’t press the “FILTER CLEAN”, it will keep brighten
after flashes about 20 second.
TIMER SET SLEEP
AIR SWING After the filter is cleaned, touch theFILTER CLEAN button on the
control
panel,and the unit will beep once (the model filter cleaning light goes out).
FILTER CLEAN
POWERFUL MODE
When the machine has been running for 500 hours, the filter cleaning light will flash for about 20 seconds and then go out after the machine
is turned on and off. If it is not reset, restart the timer. After the machine
TYPES OF SIGNAL SOUND – One long “BEEP” and one short “BEEP” . (Sound from the main unit.)
is turned on for 800 hours, the filter cleaning light will flash for about 20 seconds and then stay on. .
ACCESSORIES
Remote control
Signal Transmitter
Two R03 dry-cell batteries Drain pan
Remote Control
Display panel ON/OFF Button
TEMPERATURE Setting Button
AUTO
AIR SWING
TEMP
FAN SPEED Selection Button
Be sure to observe the following:
MODE Selection Button
FAN SPEED SLEEP
POWERFUL Button TIMER SET
Aim remote control at control panel
SLEEP Button
ON TIMER button
on air conditioner when operating. Do not drop or throw the remote control.
AIR SWING Button AIR SWING
OFF TIMER button TIMER SET button
AUTO
AIR SWING
TEMP
FAN SPEED SLEEP
AIR SWING
Do not place the remote control in a
TIMER CANCEL SET button
location that is exposed to direct
sunlight or next to a heating unit or
other heat Sources.
3 PREPARATION BEFORE OPERATING
NOTES: If operation is stopped, and to be restarted immediately, the unit will resume operation only after 3 minutes.
HOW TO INSERT BATTERIES
Open the cover.
Insert the two batteries.
Close the cover.
Do not use rechargeable (Ni-Cd) batteries because such batteries differ from the standard dry cell batteries in shape, dimensions and performance.
REMOVAL OF FRONT GRILLE 1 Open the Intake Griille until over 90°
front grille fulcrum can remove from Grille force arm.
‘SPOU(SJMMF’VMDSVN
PEZ4VQQPSU
(SJMMF’PSDFBSN
2 Remove the air filter. Tilt up and pull out the air filter by the holder.
air filter
3 Remove the front grille.
a Remove the screw on the front grille. b At the bottom right side of the
front grille,
press inward on the cabinet near the power cord, and pull the grille outward
to the right until right tab releases. c At the bottom left side, push inward
on the cabinet and pull the grille outward to the left to release the left
tab. Do not pull the bottom edge towards to you for more than 3 inches to
prevent the two top tabs from damage. d Slide the front grille upwards to
loosen the two top tabs from slots at the top of the cabinet.
ELECTRIC WORK
Always use at the rated voltage and with a specific air conditioning circuit.
This equipment must be earthed and strongly recommended to be installed with
Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD).
Otherwise, it may cause electric shock or fire in case of malfunction. Time
delay fuse or circuit breaker rating is 16 Ampere for CW-XN1821EAi20 Ampere
for CW-XN2421EA Nominal cross sectional area of power supply wire must be 3
core x 2.5 mm2 or above. The power supply must be from an independent circuit.
All electrical installations must be made in accordance with local wiring and
safety regulation wherever applicable. There must be a double pole switch with
a minimum of 3.5 mm contact gap in the fixed installation circuit. Please
engage and authorized dealer or specialist for the installation work.
CONDENSED WATER DRAINAGE
This air conditioner employs a “Slinger-Up System” which is designed to splash
the condensed water on the condenser coil for maximum cooling efficiency, thus
producing a splashing sound. If the splashing sound annoys you, you can
provide an outside drainage by using the following the procedure which may,
cause a small loss of performance.
NOTE: If the unit is installed at a coastal area, drainage of condensed water
is recommended to prevent easy condenser corrosion.
1 Remove the rubber plug and chassis locking bracket from the cabinet. Then
slides the chassis out from the cabinet.
Counter Clockwise
3 Connect a drain hose. Fit the drain hose to the drain pan.
Underside view with drain pan and hole in place.
Chassis locking bracket
2 Install the drain pan
Remove the rubber plug
Screws Drain pan
Install the drain pan at the right corner of the cabinet using 2 screws.
INTERNAL VIEW
NOTE: Drain hose or tubing can be purchased locally to satisfy your particular
needs.
4 Slide the chassis back into the cabinet. Lock the chassis to the cabinet
reusing the chassis locking bracket. Then reinstall the cabinet to the
chassis.
Clockwise
NOISE CONSIDERATION
Select an installation location that can support the weight of the air
conditioner and one that will not cause increased operating noise and
vibration. Ensure that when installed, airflow and noise from the rear side of
the unit (outdoor) do not disturb neighbouring elements. Obstacles placed in
front of the air outlet on the rear side of the unit (outdoor), or covers
placed over it will cause excessive noise and deterioration in performance.
TRANSFERRING
Repositioning or transfer of the air conditioner due to renovation or moving
requires an additional service charge. Please consult your dealer before
moving.
5 AIR CONDITIONER OPERATION
OPERATING THE UNIT
Start operation by pressing OFF/ON. The operation will turn on and the display
panel will light up. To stop the operation, press the OFF/ON again. The unit
will stop operating and the display panel light will turn off.
SETTING DISPLAY TEMPERATURE
Press TEMPorto set the display temperature. The temperature can be set between 16°C and 30°C.
Display will
Recommended temperature: 26°C~28°C NOTES:
change according
TEMP
to the
The previous set temperature will be stored and displayed when the air-con is ON.
setting.
SELECTING OPERATION MODE
Press MODE to select the desired operation.
A “beep” sound will indicate changing setting.
COOL mode COOL To set room temperature to your preference of cooling comfort.
MODE
FAN mode
DRY To provide air circulation without cooling the room. During Fan
operation, temperature setting cannot be selected.
FAN DRY mode
Mild air-conditioning operation for the purpose of reducing room humidity
(The intermittent operation of the air conditioner has achieved the purpose of dehumidification)
SELECTING FAN SPEED
FAN SPEED
Press FAN SPEED to choose the speed level of the fan. A “beep” sound will
indicate changing setting. NOTE:
The latest fan speed setting will be memorized and the indicator will light up
the next time the unit is turned on.
6 HELPFUL INFORMATION & ENERGY SAVING HINTS
HELPFUL INFORMATION Auto Restart Control
Operation will automatically resume under the previous operation mode. If the
unit was set to TIMER mode or SLEEP mode, operation will not resume
automatically. Timer Setting When power failure occurs, the timer setting is
cancelled. Once power returns, reset timer.
ENERGY SAVING HINTS
Clean the air filter every 2 weeks. Regular cleaning of the air filter
preserves efficiency. Keeping ventilation set to CLOSE closed keeps cool air
in and hor air out. Avoid direct sunlight and heat For health reason do not
overcool your room. Your air conditioner’ s cooling capacity should match your
room size.
7 CARE AND MAINTENANCE
Clean the cabinet, front grille with mild soap or detergent and lukewarm
water. The front intake grille can be easily removed for cleaning purposes
(refer to Remove the front intake grille procedures). Gently wash it with
water and a sponge. The filter can be easily cleaned using a vacuum cleaner.
Vacuum the front of the filter and then wash the rear with water. If it is
badly spoiled, wash with a mild household detergent. Do not clean with
benzene, thinner, scouring powder or cloth soaked in caustic chemicals. If the
unit is extremely dirty, heat transfer is less Efficient and the unit may not
cool effectively. Contact Shun Hing Electric Service Center Ltd. for an annual
check. (Annual check is not covered by the warranty.) If the air filter
becomes clogged with dust, the cooling capacity will drop, and 6% of the
electricity used to operate the air conditioner will be wasted. NOTE: Do not
dry the front panel or the air filter in direct sunlight.
(Exposure to direct sunlight may discolour deform the panel.)
PRE-SEASON INSPECTION Is the discharged air cold? After 15 minutes of
operation, it is normal for the temperature difference between intake and
outlet air to be more than 8°C for cooling. Are the air intake and outlet
vanes of the indoor and outdoor side obstructed? Are the remote control
batteries weak?
RECOMMENDED INSPECTION Usage over several seasons will reduce performance as
the unit becomes dirty. A dirty unit may produce foul odours and dust may clog
the dehumidifying drainage. Seasonal inspection is recommended in addition to
regular cleaning. Consult Shun Hing Electric Service Centre Ltd.,
8 BEFORE CALLING FOR SERVICE
Check the following points before calling for repairs or service. If the
malfunction persists, please contact Shun Hing Electric Service Centre Ltd.,
ADJUSTING HORIZONTAL AIRFLOW DIRECTION
AUTO AIR SWING
Press to select AIR SWING. The air circulation will automatically move the
vertical louver left and right for better air distribution around the room.
NOTE: Using your hands to adjust the direction may cause the louvres to
malfunction. If this happens, stop operation immediately and restart.
Vertical louver
POWERFUL OPERATION
To obtain set temperature quickly:
Press POWERFUL,The indicator will light up. To cancel this operation, press
once more. After POWERFUL is selected, the operation will go on for 15
minutes, after that it will shift back to previous operation mode. NOTE: Sound
emitted by the unit will be increased during POWERFUL operation due to
increased of air volume.
Cooling
-3 C lower than set temperature (lowest limit 16 C)
Super High Fan Speed
SETTING THE OFF TIMER
When the air conditioner is ON: Press the TIMER-ON button to set the timer.
Press the same button until the preferred hour of operation is reached. (The
TIMER indicator light will blink to await for setting) Press TIMER SET button
to complete the setting. At this time, the TIMER indicator light is steady
instead of blinking.
NOTE: it is unavailable to set ON TIMER and OFF TIMER simultaneously. The
timer figure will change according to the time remaining.
CANCEL OFF TIMER SETTING
CANCEL
Press the remote CANCEL button to cancel the timer setting. The TIMER indicator light will turn off. However the temperature remains displayed.
SLEEP MODE SETTING
The air conditioner will gradually increase the temperature during sleeping
time. When the set room temperature is reached, it will maintain the set
temperature for an hour and will shift 0.5°C up. The 0.5°C up will be
maintained for an hour and then will shift 0.5°C up for a total of 1°C up will
be maintained. NOTE: The automatic shift of temperature (Max 1°C) is not
indicated on the display panel.
SLEEP
Press SLEEP button to start Sleep mode. Note: If the TIMER button is pressed after selecting TIMER OFF, there will Can set off timer.
SETTING THE ON TIMER
1 4 Condition
If the unit is too noisy during operation. Condition
If water drips off the rear of the unit.
The following sounds are normal during operation:
Humidity is high.
A low humming sound indicating that the unit is operating. Condensed water is overflowing.
A soft clicking sound when the compressor turns on and off. To rectify the problem, mount an optional drain pan to the unit.
5 A flowing sound due to circulation of the refrigerant when
the compressor is turned on.
Condition
If water drips inside the room.
A splashing sound indicating condensation in the condenser coil.If you hear other noises, please consult Shun Hing Electric Service Centre Ltd.,
The unit is tilted inward. To rectify this, tilt the unit slightly outward. Mount the optional drain pan if you prefer. The drain pan may be blocked.
2 Condition
If the unit does not operate.
The main power cord is not plugged in. The main circuit breaker has tripped.
3 Condition
If the unit does not cool properly.
Condition 6
Squeaking noise during operation, Squeaking noise after shutting down (This is
due to the expansion or contraction of the model due to temperature changes)
The room is too big for the unit’ s capacity. The ventilation lever is set to OPEN The air circulation is impeded by curtains or furniture. After 15 minutes of operation, it is normal for the temperature
The air conditioner blows out cold misty Occasionally there is the sound of “GI-GA”,
air, and the indoor air comes into contact the expansion
with the cold air blown out of low
and contraction
temperature to produce misty air.
of the front leaf
window due to
temperature
changes.
There seems to be a sound of running water. This is the sound of the refrigerant flowing inside the air conditioner.
difference between intake and outlet air to be more than 8°C
for cooling.
Information for Users on Collection and Disposal of Old Equipment and used
Batteries
[Information on Disposal in other Countries outside the European Union] These
symbols are only valid in the European Union. If you wish to discard these
items, please contact your local authorities or dealer and ask for the correct
method of disposal.
Note for the battery symbol (bottom two symbol examples): This symbol might be
used in combination with a chemical symbol. In this case it complies with the
requirement set by the Directive for the chemical involved.
To call Shun Hing Electric Service Centre Ltd. IMMEDIATELY Turn off the power
and contact Shun Hing Electric Service Centre Ltd.
as soon as any of the following events occur.
The circuit breaker frequently trips or the fuse blows regularly. If water or
foreign objects have accidentally entered the air conditioner. If there is
abnormal sound during operation.
NOTE: 1. The enclosure opposing the room side is splash proof (IPX4). 2. Do
not install this appliance in a laundry room or other locations where water
may drip from the ceiling, etc. 3. If the supply cord is damaged or need to be
replaced, it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard.
IMPORTANT
- The wires in this mains lead are coloured in accordance with the following code:
Green Yellow: Earth Blue: Neutral Brown: Live
“As the coulours of the wires in the mains lead of this appliance my not correspond with the coloured markings identifying the terminals in your plug,
proceed as follows:
The wires which is coloured green and yellow must be connected to the terminal in the plug which is marked by the letter E or by the safety earth
symbol or coloured green or green and yellow. The wire which is coloured blue must be connected to the terminal which is marked with letter N
or coloured black. The wire which is coloured brown must be connected to the terminal which is marked with letter L or colour red.”
(NOTE: Replacement of installation of power plug shall be performed only by authorized/qualified personnel.)
When the air conditioner is OFF:
Press the TIMER-OFF button to set the timer. Press the same button until the
preferred hour of operation is reached. (The TIMER indicator light will blink
to await for setting) Press TIMER SET button to complete the setting. At this
time, the TIMER indicator light is steady instead of blinking.
NOTE: it is unavailable to set ON TIMER and OFF TIMER simultaneously. The
timer figure will change according to the time remaining.
CANCEL TIMER SETTING DURING ON TIMER
Press the OFF/ON or CANCEL button to cancel the timer setting.