Little GIANT 18S SERIES Sewage Pumps User Manual

June 3, 2024
Little Giant

Little GIANT 18S SERIES Sewage Pumps

APPLICATIONS

Sewage and effluent wastewater transfer, dewatering

FEATURES

  • Permanent Split Capacitor (PSC)
  • Designed for continuous duty
  • Capacitor and power cord connections are isolated from oil-filled motor housing for ease of field maintenance
  • 3″ FNPT (761 mm) discharge
  • Handles solids up to 2″ (51 mm) diameter
  • 140 °F (60 °C) liquid temperature rating
  • cCSAus listed

SERIES SPECIFICATIONS

Amps                                               Performance Shut-Off

Volts          Hz                                        Watts (GPM @ Height in Feet)                   (ft)        PSI

FLA          Start                       10′       20′       30′       40′ 50′


230| 60| 15.5| 31.0| 3512| 160| 137| 111| 84| 50| 64| 27.7
Item No.      Model         HP           Volts        Phase            Switch Type/             Cord         Weight

Operation


520301| 18S-CIM| 1-1/2| 230| 1| Manual| 20′

6.1 m

| 96 lbs

43.54 Kg

520304| 18S-CIM| 1-1/2| 460| 3**| Manual| 40′

12 m

| 94 lbs

42.64 Kg

ENGINEERING DATA

Little-GIANT-18S-SERIES-Sewage-Pumps-
fig-1Little-GIANT-18S-SERIES-Sewage-Pumps-
fig-3

PERFORMANCE DATA

CONSTRUCTION

Cover Epoxy-coated cast iron
Motor Housing Epoxy-coated cast iron
Impeller Material Red brass
Impeller Type Non-clog vortex
Volute Epoxy-coated cast iron
Mechanical Shaft Seal Carbon/ceramic
Fasteners Stainless steel
Shaft Stainless steel
Bearings Upper and lower ball bearings
Power Cord 14/3, SOW (1-phase)

www.littlegiant.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Little Giant User Manuals

Related Manuals