Tenda TEG1118P-16-250W 16GE+2SFP Ethernet Switch with 16-Port PoE Installation Guide
- June 3, 2024
- Tenda
Table of Contents
16GE+2SFP Ethernet Switch With 16-Port PoE
24GE+2SFP Ethernet Switch With 24- Port PoE
TEG1 1 1 8P-1 6-250W / TEG1 1 26P-24-410W
Quick Installation Guide
Package contents
- Switch x 1
- L-shaped bracket x 2
- Footpad x4
- Power cord x 1
- Screw (KM3*8 mm) x8
- Quick installation guide x1
This guide instructs how to install and connect the device. For more details, please visit www.tendacn.com
Install the device
1.1 Preparations
You shall prepare the following tools and materials for device installation.
- Rack mounting: ESD bracelet (or ESD gloves), screwdriver, 4 screws (to secure the switch to the rack)
- Wall mounting: ESD bracelet (or ESD gloves), marker, hammer drill, rubber hammer, screwdriver, 4 expansion bolts (M5.40 mm), 4 screws (PA5.25 mm, head diameter: 10 mm)
- Desktop mounting: ESD bracelet (or ESD gloves)
1.2 Installation
TEG1118P-16-250W is used as an example for illustration here.
-
Rack mounting (to a standard 19-inch rack)
Step 1 Ensure that the rack is stable and level, and is properly grounded.
Step 2 Fix the two L-shaped brackets to both sides of the switch using the included screws. Step 3 Choose a proper height and fix the L-shaped brackets to the rack using screws (self-prepared). Ensure that the switch is seated securely on the rack. -
Wall mounting
Note:- Do NOT install the switch with its air vents facing downward; othenvise, there will be potential safety hazards.
- This switch can only be installed on a concrete or non-flammable wall.
Step 1 Rotate the two L-shaped brackets by 90 degrees and fix them to both sides of the switch with the included screws. Step 2 Horizontally place the switch onto the wall with its RJ45 ports facing upward. The mark the screw holes with the marker on the wall.
Step 3 Drill holes in the marked positions with a hammer drill, and then knock the expansion bolts (sett-prepared, M5.40 toe) into the holes.
Step 4 Insert the screws (self-prepared, PA5*25 mm, head diameter: 10 mm) through the holes of the two L-shaped brackets, and secure the screws into the expansion bolts with a screwdriver. Ensure that the switch is installed firmly with its RJ45 pods facing upward.
-
Desktop mounting
Paste the four footpads to the four recesses on the bottom of the switch. Then turn the switch upside down, and place it on a big enough, clean, stable and flat desktop.
Connect the device
The typical network topology of the switch is as shown below.
TEG1118P-16-250W is used for illustration.
Note:
- The switch supports auto MDI/MDIX. You can use either a straight through cable or a crossover cable to connect the switch to Ethernet devices.
- The switch supports power supply priorities for the PoE ports. when the total power consumption of the PoE-powered devices exceeds the maximum output of the switch, the switch starts cutting the power supply from the port with the lowest power supply priority (the port with the largest port number) until the total power consumption of the PoE-powered devices is less than the maximum output of the switch.
After connection, you can check whether the switch is connected properly or change the working mode according to the following table.
LED indicator/ Toggle | Description |
---|---|
SFP1, SFP2, Link/Act | Solid on: The port is connected to a device, but no |
data is being transmitted over the port.
Blinking: The port is connected to a device, and data is being
transmitted over the port.
Off: The port is not connected or is not connected properly.
PoE-MAX| Solid on: The total PoE output power reaches the maximum output
power of the switch.
Off: The total PoE output power does not reach the maximum output power
of the switch.
Power| Solid on: The switch is powered on properly.
Off: The switch is not powered on or not powered on properly.
Working mode toggle| Standard: Default mode of the switch. In this mode,
the switch works as an ordinary unmanaged switch, and all ports can
communicate with each other.
Priority: In this mode, ports’) to 8 serve as ports with high priority.
All ports can communicate with each other.
When multiple IP cameras are connected to the switch, you can use this mode
and connect the IP cameras in key surveillance areas to the ports with high
priority, and the uplink devices (such as NVR and router) to the two uplink
ports. This guarantees a higher priority for IP cameras in key surveillance
areas when network congestion occurs, and improves the smoothness of the
monitoring videos.
Extend: In this mode, the port statuses of the switches are as shown
below.
• For TEG1118P-16-250W, the maximum transmission distance of ports 9 -14 can
reach 250 meters, and all ports can communicate with each other.
• For TEG1126P-24-410W, the maximum transmission distance of ports 17 – 22 can
reach 250 meters, and all ports can communicate with each other.
For a better network extension effect, please use CAT5e Ethernet cables or
above, and set the speed and duplex mode of the port of the peer device to
Auto-negotiation. If the peer device is an IP camera, set its bit rate below 8
Mbps for timeliness of video transmission.
VLAN: In this mode, the working statuses of the switches are as shown
below.
•For TEG1118P-16-250W, ports 1 -14 cannot communicate with each other, but can
communicate with ports 15, 16, SFP1, and SFP2.
•For TEG1126P-24-410W, ports 1 – 22 cannot communicate with each other, but
can communicate with ports 23, 24, SFP1, and SFP2.
VLAN mode helps isolate DHCP broadcast and reduce broadcast storm.
Specifications
Model | TEG1118P-16-250W | TEG1126P-24-410W |
---|---|---|
Port | 10/100/1000 Mbps RJ45 port | 16 |
1000 Mbps SFP port | 2 |
TEG1118P-16-250W: 2 independent SFP ports
TEG1126P-24-410W: Port 23 and port SFP1 compose a combo port, and port 23 owns a higher priority. Port 24 and port SFP2 compose a combo port, and port 24 owns a higher priority.
Working mode| Standard, Priority, Extend, VLAN
Performance| Switching mode| Store-and-forward
MAC address table teaming| Auto aging, auto learning
MAC address table| 8 K
PoE power supply| PoE standard| IEEE 802.3af, IEEE 802.3at
PoE power cable core| 8 cores: voltage of cores 1, 2, 4, 5 is +, and cores 3,
6, 7, 8 is –
PoE port| 1 – 16| 11 – 24
Maximum output power of a single port| 30W
Maximum output power of the switch| 230 W| 370 W
Dimensions (L x W x H)| 440 mm x 179.6 mm x 44 mm| 440 mm x 284 mm x 44 mm
Input voltage| 100 – 240V AC, 50/60Hz, 4 A| 100 – 240V AC, 50/60Hz, 6 A
Lightning protection| RJ45 port| Common mode: 6 kV
power supply| Common mode: 6 kV Differential mode: 4 kV
Operating environment| Temperature: 0°C – 45°C
Humidity: (10% – 90%) RH, non-condensing
Storage environment| Temperature: -40°C – 70°C
Humidity: (5% – 90%) RH, non-condensing
Data transmission rate| Ethernet: 10 Mbps (half duplex)/20 Mbps (full duplex)
Fast Ethernet: 100 Mbps (half duplex)/200 Mbps (full duplex)
Gigabit Ethernet: 2000 Mbps (full duplex)
Transmission media| Fast Ethernet: CATS UTP/STP or better
Gigabit Ethernet: CAT5e or CAT6 UTP/STP
1000Base-SX: MMF
1000Base-LX: MMF or SMF
Network standards| IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab,
IEEE 802.3z, IEEE 802.3af, IEEE 802.3at
Safety and statement
Safety Precautions
Before performing an operation, read the operation instructions and
precautions to be taken, and follow them to prevent accidents. The warning and
danger items in other documents do not cover all the safety precautions that
must be followed. They are only supplementary information, the installation
and maintenance personnel need to understand the basic safety precautions to
be taken
- Do not use this apparatus near water.
- Clean only with dry cloth.
- Do not block any ventilation openings, such as newspapers, table-cloth, curtains, etc.
- Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus that produce heat.
- Do not damage the ground conductor or operate the device in the absence of well installed ground conductor. Conduct the appropriate electrical inspection.
- Protect the power cord from being walk on or pinched particularly at the plugs, convenience receptacles and at the point where they exit from the apparatus.
- Only use attachrnents/accessories specified by the manufacturer.
- Unplug this apparatus during lighting storms or when unused for long periods of time.
- Mains plug is used as the disconnect device, the disconnect device shall remain readily operable
- Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
- Warning: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. The apparatus shall not be exposed to dripping or splashing.
- Warning: To reduce the risk of electric shock, do not remove cover as there no user-serviceable parts inside. Refer servicing to qualified personnel.
CE Mark Warning
This is a Class A product. In a domestic environment, this produ. may cause
radio interference, in which case the user may be required to take adequate
measures.
The mains plug is used as disconnect device, the disconnect device shall
remain readily operable.
NOTE: (1) The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. (2) To
avoid unnecessary radiation interference, it is recommended to u. a shielded
RJ45 cable.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communi-cations. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Caution!
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
NOTE: (1) The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. (2) To
avoid unnecessary radiation interference, it is recommended to use a shielded
RJ45 cable.
RECYCLING
This product bears the selective sorting symbol for Waste electrical and
electronic equipment (WEEE). This means that this product must be handled
pursuant to European directive 2012/19/EU in order to be recycled or
dismantled to minimize its impact on the environment. User has the choice to
give his product to a competent recycling organization or to the retailer when
he buys a new electrical or electronic equipment.
Technical Support
Shenzhen Tenda Technology Co., Ltd.
6-8 Floor, Tower E3, NO.1001, Zhongshanyuan Road,
USA hotline: 1-800-570-5892
Toll Free: 7 x 24 hours
Canada hotline: 1-888-998-8966
Toll Free: Mon – Fri 9 am – 6 pm PST
Hong Kong hotline: 00852-81931998
Global hotline: +86 755-2765 7180 (China Time Zone)
Website: www.tendacn.com
E-mail: support@tenda.com.cn
Copyright
©2020 Shenzhen Tenda Technology Co., Ltd. All rights reserved.
Tenda is a registered trademark legally held by Shenzhen Tenda Technology Co.,
Ltd. Other brand and product names mentioned herein are trademarks or
registered trademarks of their respective holders. Specifications are subject
to change without notice.
Read User Manual Online (PDF format)