RELiON 12V120-GC2-LT INSIGHT 12V Lithium Battery User Guide

June 4, 2024
RELiON

RELiON 12V120-GC2-LT INSIGHT 12V Lithium Battery User Guide
RELiON 12V120-GC2-LT INSIGHT 12V Lithium Battery

This Quick Installation Guide contains important information regarding the proper installation of your InSight Series™ lithium battery. This QIG applies to all RELiON InSight Series lithium batteries.

USE PARALLEL CONNECTIONS

InSight batteries are only to be connected in parallel to meet your energy requirements. They cannot be connected in series. See wiring diagram.

  12V 24V 48V
Parallel Connections Unlimited Unlimited Unlimited
Series Connections None None None

INSTALL THE BATTERIES CLOSE TOGETHER

If you are replacing your existing batteries with fewer than the original batteries, install the new InSight batteries close to each other in the battery compartment.

USE RELION INSIGHT BATTERY SPACERS

We recommend using our Battery Spacers to fill the empty battery spots so you can use the existing battery hold-downs that come in your vehicle. These can be purchased on our website at relionbattery.com. If you do not use our Battery Spacers, please ensure your InSight batteries are securely held down.

CABLE SIZE

Be sure to use cables of equal lengths to connect your InSight batteries.

TORQUE

Use the proper torque. 79.7 – 88.5 in-lbs . 6.6 – 7.4 ft-lbs . 9 – 10 N-m

UTILIZE CAN CABLES

CAN cables (1 ft) are provided with your InSight battery. Starting with the first battery connect the CAN cable from the Output (positive battery side) to the Input of the 2nd battery (negative battery side) and so on. The CAN port on the negative side of the 1st battery and on the positive side of the last battery will remain unused. Longer CAN cables (2 and 4 ft) are available upon request.
The CAN cables have 90° connectors. CAN cables with 180° connectors are available upon request.

POWER THE BATTERY ON

Once connected, press and hold the Power button on one of the batteries until you see the first LED flash green. It will continue to flash green every 5 seconds. You will notice that once you wake up one battery the remaining batteries will automatically wake up. Once the batteries are awake, you can tap the Power button to see the state-of-charge (SOC) of each battery. Refer to Table 3 to determine the SOC. If the batteries are not at an equal SOC, they will balance upon being used. Refer to Table 2 for how to turn off the battery.

CHARGING

It is best to use/select a Lithium, GEL or AGM charge profile in that order of availability.

COMPATIBLE ACCESSORIES AVAILABLE

The backlit InSight Fuel Gauge is a plug-and-play accessory that provides real-time State of Charge. The InSight Remote Button gives you the convenience to power your InSight batteries on and off without having to access the battery compartment. These can be purchased on our website at relionbattery.com.

Instructions

  1. Dual M8 Terminals
  2. CANbus Input (negative side)
  3. CANbus Output (positive side)
  4. Power Button
  5. SOC/Status LEDs
  6. Heatsink
  7. Vent
  8. Lifting Brackets

BATTERY INTERFACE

The battery cover has two tri-colored LEDs (green, yellow, and red) that are used to communicate the status of the battery, the SOC of the battery, as well as protection modes and errors. LED1 is on the left side and LED2 is on the right side of the LED display when facing the battery from the positive post side.

LEDS – BATTERY MODES

MODE LED 1 LED 2
OFF OFF OFF
ON Flashing Green (5 sec) OFF
Charging OFF Flashing Green (2 sec)

WAKE UP BUTTON FUNCTIONS

ACTION OPERATION REMARKS
Power ON Press and hold button for 5s until:

·         LED1 Flashes Green

·        Then release button

| Battery will turn ON
Display SOC| With battery ON

Tap button once

| LED displays for 6 sec. See SOC STATUS Table 3
Power OFF| Tap, release, then press and hold button for 6s until:

·            LED1 Solid Red

·            LED2 Solid Red

·            Then release button

| Battery will turn OFF

LEDS – SOC STATUS (INITIATE WITH SINGLE TAP OF THE POWER BUTTON)

SOC LED 1 LED 2
95% – 100% Solid Green Solid Green
75% – 95% Solid Green Flashing Green
50% – 75% Solid Green Solid Yellow
30% – 50% Solid Green Flashing Yellow
10% – 30% Solid Green Solid Red
0 – 10% Solid Green Flashing Red

PRECAUTIONS

Lithium Iron Phosphate (LiFePO4) batteries are an inherently safe chemistry. Please reference RELiON’s Lithium Iron Phosphate Safety Document (available on our website at relionbattery.com) for more details. However, as with any electronics, safety measures should always be taken. Please adhere to these instructions for safe handling and operation:

  • Wear safety glasses when installing batteries
  • Use a wrench with a rubber coated handle
  • Do not place any objects on top of batteries
  • Make sure all cable connections are properly tightened
  • Refer to RELiON’s LiFePO4 SDS for additional information

TECHNICAL SUPPORT

If you have technical questions about your RELiON battery, please contact the original place of purchase or RELiON Battery directly:

RELiON-Technical@OneASG.com
+1 803-547-7288
Relionbattery.com

WE’RE HERE TO HELP.
Check out our Knowledge Help Center at Relionbattery.com/Knowledge. You can search for a topic by keyword or simply browse through various articles by category.

RELiON Battery provides our customers with the highest quality and safest lithium products, in compliance with all regulatory standards.
©2022 RELiON Battery, LLC. All rights reserved. RELiON is not liable for damages that may result from any information provided in or omitted from this publication, under any circumstances. RELiON reserves the right to make adjustments to this publication at any time, without notice or obligation.

INSIGHT 12V QIG
07.26.22

For more detail, please refer to RELiON’s User’s Manual,
available at: relionbattery.com/resources/documentation

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals