ANALOG DEVICES Current Measurement-Grid Monitoring Precision CT Measurement User Guide

June 3, 2024
Analog Devices

ANALOG-DEVICES-logo

ANALOG DEVICES Current Measurement-Grid Monitoring Precision CT

Measurement

ANALOG-DEVICES-Current-Measurement-Grid-Monitoring-Precision-CT-Measurement-
product

POWER SOLUTIONS FOR PRECISION TECHNOLOGY SIGNAL CHAIN

PRECISION CURRENT SENSING Current Measurement – Grid Monitoring Precision CT MeasurementANALOG-DEVICES-Current-Measurement-Grid-Monitoring-Precision-CT-
Measurement-fig 1

This document is interactive. You can click on any underlined text to navigate through the document

For the resources:ANALOG-DEVICES-Current-Measurement-Grid-Monitoring-
Precision-CT-Measurement-fig 2

For the individual pages:ANALOG-DEVICES-Current-Measurement-Grid-
Monitoring-Precision-CT-Measurement-fig 3

ANALOG-DEVICES-Current-Measurement-Grid-Monitoring-Precision-CT-Measurement-
fig 4

Current Measurement

Grid Monitoring Precision CT Measurement

PART # DESCRIPTION
ADuM6422A Quad-

Channel Isolators with Integrated DC-to-DC Converter (2:2 directionality)
LT3027| Dual 100mA, Low Dropout, Low Noise, Micropower Regulator with Independent Inputs
LT8338| 40V, 1.2A Micropower Synchronous Boost Converter with PassThru
LT8606| 42V, 350mA Synchronous Step-Down Regulator with 2.5μA Quiescent Current

POWER REQUIREMENTS


PARAMETER

| STAGES| Filter| ADC| Isolation| Reference
---|---|---|---|---|---
Part #| –| AD7606B| ADuM6422A| ADR4525
Pin|  | AVCC| VDRIVE| VDDP| VDD1| VDD2| IN
Supply Voltage| V| –| 5| 3.3| 5| 5| 5| 5
Supply Current| mA| –| 47.5| 1.5| 25| 12| 14| 0.95
PSRR| dB| –| 68 (100kHz; ±10V range)| –| –| –| 80 (1MHz)

  • Note 1: The supply currents indicated are the maximum quiescent current of the supply rails. For overall full load or short circuit current specifications, refer to the datasheets of the signal chain components.
  • Note 2: The supply voltages indicated are the values for typical applications.
  • Note 3: Consult the corresponding datasheets for details on: (1) power supply rejection ratio (PSRR) and (2) power dissipation.
  • Note 4: The actual supply current requirement shall be multiplied depending on the number of channels on the signal chain.