Miele PDR 928 G Professional Vented Dryer Installation Guide

June 3, 2024
Miele

Miele PDR 928 G Professional Vented Dryer Installation Guide

Miele PDR 928 G Professional Vented Dryer Installation
Guide

Installation notes

Installation requirements

The tumble dryer must only be installed and commissioned by Miele Customer Service Department or an authorised dealer. The tumble dryer must be installed in accordance with all relevant regulations and standards. The dryer must only be operated in a room that has sufficient ventilation and which is frost-free.

Electrical connection

The electrical connection must be established by a qualified electrician. The electrical connection may only be made to an electrical system provided in accordance with all appropriate local and national legislation, regulations and guidelines. Please also observe the regulations set out by your insurance provider and energy supplier, accident prevention regulations, as well as recognised codes of practice. Reliable and safe operation of this tumble dryer is only ensured if it has been connected to the mains electricity supply. The required supply voltage, power rating and fuse rating can be found on the data plate on the tumble dryer. Ensure that the supply voltage matches the voltage quoted on the data plate before establishing the electrical connection to the tumble dryer. Connection to a supply voltage other than the one quoted on the data plate can damage the tumble dryer if the voltage is too high. If more than one voltage is specified on the data plate, the tumble dryer can be converted for connection to the relevant input voltage. This conversion must be performed by the Miele Customer Service Department or by an authorised dealer. During the conversion, the wiring instructions given on the wiring diagram must be followed. The tumble dryer can either be hard-wired or connected using a plug-and-socket connection in accordance with IEC 60309-1. For a hard-wired connection, an all-pole isolation device must be available at the installation site. An isolation device is a switch which ensures a contact opening of more than 3 mm. These include circuit breakers, fuses and contactors (IEC/EN 60947). If the mains supply cannot be permanently disconnected, the isolation device (including plug and socket) must be safeguarded against being switched on either unintentionally or without authorisation.
Tip: We recommend connecting the tumble dryer to the power supply via a plug and socket so that it is easier to conduct electrical safety checks (e.g. during maintenance or repair work). The tumble dryer must not be connected to devices such as timers which would switch it off automatically. If local regulations require that a residual current device (RCD) is installed, a type B residual current device (sensitive to universal current) must be used.

Gas connection

The gas connection must only be carried out by a registered installation technician in accordance with the applicable national regulations (see installation instructions).

The use of a gas socket is not permitted at the specified heater rating as the flow rate is too low.

The gas heating is configured at the factory in line with the gas specifications on the sticker on the rear of the appliance.

If the gas family is changed, a conversion kit must be requested from the Miele Customer Service Department (please specify the appliance type, serial number, gas family, gas group, gas connection pressure and country of installation). Follow the installation instructions. This conversion may only be carried out by a registered specialist.

Air intake/exhaust air

The tumble dryer may only be operated when the ducting has been connected properly and the room is sufficiently ventilated. Accessory parts may only be fitted when expressly approved by Miele. If other parts are used, warranty, performance and product liability claims will be invalidated.

PDR 928/528, gas heated

Dimensions

Miele PDR 928 G Professional Vented Dryer Installation Guide -
Dimensions

Dimensions quoted in millimetres

Installation

Miele PDR 928 G Professional Vented Dryer Installation Guide -
Installation

Measurements in millimetres
EL Electrical connection
G Gas connection
AL Exhaust duct
ZL Air intake
XCI XCI Box/Connector Box (optional)

Installation (standard/on concrete plinth)

Miele PDR 928 G Professional Vented Dryer Installation Guide -
Installation

Dimensions quoted in millimetres
B Drill hole/anchor point
BS Concrete plinth

Technical data

Voltage variants/electrical data

Miele PDR 928 G Professional Vented Dryer Installation Guide - Voltage
variants

Gas connection

Miele PDR 928 G Professional Vented Dryer Installation Guide - Gas
connection

Waste air/gas

Miele PDR 928 G Professional Vented Dryer Installation Guide - Waste
air

Air intake

Miele PDR 928 G Professional Vented Dryer Installation Guide - Air
intake

Machine data

Miele PDR 928 G Professional Vented Dryer Installation Guide - Machine
data

Fixing options
Fixing without plinth

Miele PDR 928 G Professional Vented Dryer Installation Guide - Fixing
without plinth

Fixing to concrete plinth

Miele PDR 928 G Professional Vented Dryer Installation Guide - Fixing to
concrete plinth

Options/Accessories
Concrete base (on site)

Miele PDR 928 G Professional Vented Dryer Installation Guide - Concrete
base

Miele & Cie. KG Carl-Miele-Straße 29 33332 Gütersloh Germany
Telefon: 05241 89-0
Telefax: 05241 89-2090
Internet: www.miele.com/professional

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals