TOPKODAS PROGATE Cellular GSM Gate Opener GSM Access Gate Control User Guide

June 3, 2024
TOPKODAS

TOPKODAS PROGATE Cellular GSM Gate Opener GSM Access Gate Control User Guide
TOPKODAS PROGATE Cellular GSM Gate Opener GSM Access Gate
Control

Specifications

  • Network technology: LTE CAT-1 or GSM/GPRS/EDGE
  • Administrators: up to 8 can receive SMS and Call
  • Users database (Phones, iButton, RFID, Codes): up to 800
  • Power supply: AC 10-24 V 50 Hz ~ 200 mA max / DC 10-30 V 200 mA max
  • Current consumption in idle state w/o external devices connected: up to 50mA
  • Number of inputs: 2
  • Zone: NC, NO or EOL=5.6kΩ (settable) or analog: 0-30V (settable)
  • Number of I/O input/output: 2
  • Open Drain 24V/1A,
  • Zone: NC, NO or EOL=5.6kΩ (settable)
  • Relay Output: 1A 30 V DC, 0.5A 125 V AC
  • Wiegand interface: 26-bit Wiegand format, 8-bit Keypad PIN/CODE format
  • Maxim’s 1-Wire® interface: iButton Keys DS1990A; temperature sensors DS18b20
  • Aosong 1-wire Humidity/Temperature Sensor AM23xx
  • Buffer for unsent events: up to 3072 events
  • Nonvolatile flash Event LOG: up to 3072 events
  • Dimensions: 73x62x26mm
  • Operating temperature range: -20…+55 °C
  • Module weight: 70g
  • Package weight: 90g
  • Humidity: 0-90% RH @ 0… +40°C (0-90% RH @ +32… +104°F) (non-condensing)

LED indication

LED Indication variations Meaning
POWER (green) Watchdog blinking, on 50ms,off for 1000ms The module is

functioning.
Off| No power voltage.
NET (yellow)| Lights continuously| Modem is registered
Flashes, remains lit for 50ms, turns off for 300ms| Modem is being registered to the network.
Blinking fast, 50ms on, and off for 50ms| PIN code of SIM card error. PIN code request should be removed
Off| Modem is not registered
DATA (red)| Lights continuously| Module contains unsent reports to the user or to the server.
Off| All reports has been send.
RELAY(blue)| On/Off| Relay state On/Off

Quick set up of the controller

  1. Insert SIM card. Turn off PIN code requests

  2. Screw GSM antenna,

  3. Connect power supply 10-30VDC
    Note: the USB power supply can only be used for configuration. It is not sufficient to power the modem.

  4. Call to the module.
    Note: The first one to call the controller will become the system administrator. Device will turn on the RELAY output for 2 seconds. The phone number will be stored in the module’s memory automatically. The caller will receive a greeting SMS with the IMEI of the module. At this moment all calls from different phone number will be rejected. The controller can be installed without any additional configuration if such operation mode is acceptable.

  5. Configuration and control methods:
    SERA2 – configuration software via USB or Internet remote
    https://www.topkodas.lt/Downloads/SERA2_Setup.exe
    SERANOVA – Free WEB app https://seranova.eu/login
    SMS – configuration with INST commands.
    Complete SMS commands can be found in full Installation & Programming manual
    Manual https://www.topkodas.lt/product/progate-4g.

SMS commands

Add/Edit User to receive SMS/DIAL notifications:

INST000000˽001˽N#TEL#SMS#DIAL# 001= command; N = user index 1-8; TEL = telephone number international format without (+); SMS = notifications event filter; DIAL = event filter; #= delimiter Event filter from left to right 0-disabled; 1-enabled:

  1. Alarm/Restore (CID 100 group)
  2. System Open/Close (CID 400 group)
  3. System Troubles (CID 300 group)
  4. Sensor1-Sensor32 Alarm/Restore
  5. Test Events (CID 600 group)
  6. Other Events
  7. Input/Zone1 Alarm/Restore
  8. Input/Zone2 Alarm/Restore
    And so on Input/Zone3 to …n etc

e.g. INST000000˽001˽1#37066666666#0000000000#0000000000#
This example disable all User1 SMS and DIAL notifications

Delete SMS/DIAL user by index:
INST000000˽002˽ID ID = user index number from 1 to 8

Add user to Remote Control output or Arm/Disarm:
INST000000˽004˽ID#TEL#OUT#OPT#NAME# 004= command code (enter user‘s telephone number for remote control via short call)
ID = user index 1-800, TEL = user‘s phone #;
OUT= output number 1-32. 0-disabled
OPT = 0 – disabled 1 – enabled, Sequence from the left to the right

  1. User Enabled
  2. Enable Arm/Disarm alarm system by call

NAME = User Name
e.g.INST000000˽004˽1#37066666666#1#10#Jon#

Delete all user data by index:
INST000000˽006˽ID ID = user‘s index number from 001 to 800.

Setting parameters using SERA2 software

With SERA2 software you can change the controller’s settings (if default settings are not enough)

  1. Download the configuration software SERA2 from
    https://www.topkodas.lt/downloads/ and install it.

  2. Connect the controller to a computer using a mini USB cable.

  3. Launch the configuration software SERA2. The program will automatically recognize the connected device.

  4. Click Read to see current controller parameters

Note: The button [Read] will read configuration and show the settings currently saved on the device.
The [Write] button will save the settings to the flash memory.
The button File> [Save] will save the configuration to file for later use.
This allows to quickly configure multiple devices with the same settings.
The button File> [Open] open configuration file and load saved settings.
To revert to the default settings, go to Update FW without checking the Preserve settings checkbox.

SERANOVA app

With SERANOVA app users will be able to control the GATE remotely and administrate users. They will also be able to see the system state and receive push Notifications, all event messages.
Free WEB SERANOVA app https://seranova.eu/login

Scan QR code and install SERANOVA app.
Seranova app icon

QR code

QR code

New User? Please create an account.

SERANOVA & SERA Cloud Service

To use the SERANOVA app or the SERA2 remote connection. The SERA cloud service needs to be activated by using the SERA2 or SMS command e.g. INST000000˽010˽1. By default this service is activated.

Important! If there is no data plan on your SIM card. [SERA Cloud service] must be deactivated. Using SERA2 or SMS command: INST000000˽010˽0 Otherwise the module will stop working due to a lost data connection.

SMS command to set APN DATA/GPRS/LTE network settings INST000000˽008˽APN#LOGIN#PSW#
e.g.INST000000˽008˽internet### where APN=’internet’;

Ways to get device IMEI (UID)
  • First call to module. The caller will receive a greeting SMS with the IMEI of the module.
  • By SMS sending command. INST000000˽100˽1
  • Run SERA2 and connect device to USB.
    go to: SERA2> System Options> System Info
Add a new system to SERANOVA app
  • Enter the IMEI (UID)
  • Enter App key. Default 123456.
  • Enter user access code. Default 123456. Without a user access code, user unable to control system.
  • Enter system SIM phone number
  • Enter system name.
  • Press [Save]
Add additional system

A SERANOVA user can add an unlimited number of systems. Go to SYSTEMS> [Add new system]

Add a new user
  • New user must download the SERANOVA app and create an account
  • System admin press SERANOVA>Menu>Users> [Add new User].
  • Fill all required fields: email, user code, output, user permissions

****Enter a valid email address of a user who already has a SERANOVA account. The system will automatically be added to the user’s account.

Add the System manually

The user must log in to SERANOVA account with the same email that the admin added to user list. Then the admin has to tell PROGATE details IMEI, user access code. And only then the user will be able to add the system to their app see: 4.3

Installation & wiring

Mounting types

Wall mounting. (No need to open enclosure!)
Mounting types

  • Velcro stick- on adhesive fasteners
  • DIN Rail mounting
  • Flush mounting over electric wall box
    Following the connecting diagram, connect the relay contact to the device you wish to control and connect the power supply:
Wiring diagram for automatic gate opener

**** All wiring should be done with the power supply disconnected!
Usually the contacts you need to connect from gate control unit to the PROGATE module are a certain input (x IN) and common terminal (COM).

The automatic gate has a gate state position output (OUT) that shows when the gates are closed and when they are open. The intermediate relay K1 is turned on when the gates are open and it activates the
PROGATE IN1 input. The state of the PROGATE module’s IN1 input gives precise information about the state of the gates (when the gates are closed and when they are open).

Wiegand keypad & RFID card reader wiring

Wiring Diagram

  • Connect Wiegand keypad as shown in the Fig
  • How to configure Wiegand keypad:
  • Install SERA2 software. Device> PROGATE
  • Connect the module to the computer via mini USB cable

Enter RFID Keycard codes manually.

In that case, you have to:

  1. Go to “Users& Remote Control” table. Enter RFID Keycard number and other required parameters
  2. Enter RFID Keycard codes for users.
  3. Select RFID Keycard action OUT/ARM/DISARM, etc.
  4. Write the configuration into the module by pressing “Write” icon

Enter RFID Keycard codes automatically via SERA2 software.

  1. Press [Learn i Buttons/RFID mode] in:
    SERA2> System Options> General System Options. .

  2. Write configuration by pressing “Write” icon.

Enter RFID learning/ deleting mode by sending SMS message

Send SMS: INST000000˽063˽S
S= keys entering/deletion mode.

0- Disable
1- Keys learning mode
2- Keys deleting mode

iButton Keys

Maxim-Dallas iButton keys (iButton DS1990A – 64 Bit ID)) can be used to control selected output or ARM/DISARM alarm system. Up to 800 iButton keys can be assigned to the system.
iButton keys can be assigned in the same way as RFID. See: 6
iButton Keys

Remote control

Control using SERANOVA app
  • How to start SERANOVA app read paragraph 4
  • Add an output widget and set the output parameters: name; pulse/level; icon; and other…
  • If the gate is controlled by impulse.
    Select the input associated with the gate position sensor to reflect the actual state of the gate.
    Remote control
Control with phone call

The first one to call the controller will become the system administrator. Call the number of the SIM card inserted into the controller. The controller automatically rejects the call and turns on the RELAY output for 2 seconds and will be the only one who can administer and control the controller with free short call, SMS commands.

Control with SMS messages

Activate or deactivate selected output
USER123456˽021˽N#ST
021 = command code (Activate or deactivate selected output N)
N = output number 1-32; ST= output mode: 0 – deactivated output, 1- activated output
e.g. USER123456˽021˽1#1 Activate OUT1

Output pulse activation for the time interval

USER123456˽022˽N#TIME#
022= command code, N = output number 1-32; TIME = 0-999999 Time interval in seconds for the output activation.
e.g. USER123456˽022˽2#5# Activate OUT2 for 5 seconds

This Quick Start Guide provides only basic information about the device.
For more detailed information, please refer to the full manual:
Installation & Programming Manual

Website: https://topkodas.lt
Email: info@topkodas.lt

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TOPKODAS User Manuals

Related Manuals