TOPKODAS GTCOM2 GSM Communicator Contact ID to SMS Converter User Guide
- June 3, 2024
- TOPKODAS
Table of Contents
GTCOM2 GSM Communicator Contact ID to SMS Converter
User Guide
GTCOM2 GSM Communicator Contact ID to SMS Converter
UAB “Topkodas”, JSC
Mobile: +370 655 58449, E-mail: info@topkodas.lt
http://www.topkodas.lt
FREE SeraNova web app: https://seranova.eu/login
FREE SeraNova Mobile app:
https://play.google.com/store/apps/details?id=com.seranova.cloud
When primary alarm panel is triggered, it signals the alarm communicator which
in turn notifies a CMS. Integrated SIA IP DC-09 protocol.
The module receives Contact ID DTMF codes from the dial-up communicator of
security control panel, converts them into readable texts and sends SMS
message to the mobile phone of a user.
It is possible to check the status, control the panel via mobile app.
Selectable 2G, 3G or 4G LTE modem. App notifications, Call alarms,
SMS alarms, Events log list.
Configuration templates and remote configuration possibility. Easy
SIM card, USB access. No need to open enclosure!
REQUIREMENTS OF THE SECURITY CONTROL PANEL The security control panel
should meet the following requirements:
- To support Ademco Contact ID protocol according to SIA DC-05 standard.
- To support dialing in DTMF tones.
- To support Contact ID data transfer in DTMF tones.
- It is recommended for the control panel to support automatic Contact ID codes.
MEANING OF LEDS AND CONTACTS
Name | Indication variations | Meaning |
---|---|---|
REG (yellow) built-in LED | Lights continuously | Modem has been registered to |
the network
Flashes,
remains lit for
50ms, turns off for 300ms| Modem is being registered to the GSM network.
Blinking fast,
remains lit for 50ms turns off for 50ms| PIN code of SIM card error. PIN code
request should be removed
Off| Modem failed to register to the network.
DATA (red) built-in LED| Lights continuously| The memory of the module
contains unsent reports to the user or to the server.
Off| All reports has been send.
PWR (green) built-in LED| Watchdog heart
beat blinking,
remains lit for 50ms, and turns off after 1000ms.| The module is functioning.
Off| The module is out of order or no voltage
LINE (blue)| Lights continuously| The security control panel
has picked up a handset Off-hook
OFF| The security control panel
has not picked up a handset On-hook
DTMF| Blinking 5-10ms| DTMF tones are receiving from the control panel
Blinking 1s| DATA OK. Data received
correctly.
LINE (blue) LED lights continuously, when central panel OFF HOOK DTMF LED is blinking (5-10ms). When DTMF LED lights for 1s, data received correctly.
FIRST STEPS TO PREPARE GTCOM2 MODULE & SERA2
SOFTWARE
Preparation procedure of the module GTCOM2.
-
Connect the GSM antenna to the antenna connector.
-
Insert the SIM card in the SIM card holder.
Ensure that PIN request function is disabled.
Ensure that mobile internet service (mobile data) is enabled if mobile app or IP connection with CMS will be used.
To avoid entering the PIN code in Sera2 software, insert the SIM card into your mobile phone and turn off the PIN request function. -
Connect the module to the primary alarm panel.
-
Connect the module to the computer via mini USB cable
Install configuration software SERA2
Download SERA2 from www.topkodas.lt , install and open it.
If you want to edit existing configuration,
You have to read it (press “Read” in the command line). Edit settings. Write
edited configuration (press “Write” in the command line)
COMMUNICATOR WIRING METHODS
The alarm panel is linked up with GTCOM2 communicator via the RING and TIP
terminals simulating the connectivity of the PSTN line.
RING/TIP interface – Retrieves Ademco Contact ID data from the alarm panel,
converts it into user-understandable text and delivers to up to 8 listed users
by SMS text message.
The outputs can also be used for arming/ disarming by connecting an output to one of the alarm panel’s zones preconfigured as a keyswitch. If the control panel status changes from ARM to DISARM, the status of GTCOM2 changes from ARM to DISARM also If the siren is triggered, the SMS will be send to the user’s mobile followed by a call GTCOM2 could be used for all control panel control, gate control. The second keyswitch can be used to stay ARM. The first keyswitch could be used for arm the first partition and the second keyswitch can be used for arm the second partition
ALARM PANEL & GTCOM2 SYNCHRONIZATION
Control primary panel via short call, app, SMS
Control primary panel from GTCOM2 and see the status in app
Control primary panel from GTCOM2 and see the status in app Receive status
SMS.
See the same status in keypad Control GTCOM2 from primary panel and see the
status in keypad.
Control GTCOM2 from primary alarm panel and see the status in keypad
The same status in mobile app and SMS
How to set primary panel?
Configuration of the panel PSTN communicator should be the similar as event
transmission to the monitoring station receiver in CONTACT ID DTMF protocol.
Practically the module can work with any central panel which has PSTN
communicator and meets Ademco Contact ID data format according to SIA SIA DC05
standard. Also Central panel must support phone number dialing using DTMF
tones.
Panel’s PSTN communication settings:
Set communication enabled
Set communicator account number 4 digits. E.g. “1234”
Set communications Telephone. Enter the monitoring station receiver’s
telephone number (you can use any number longer than 2 digits. The GTCOM2 pick
up and answer when the panel calls to any phone number). Telephone number
e.g. “1234”.
Set communication dialing options to [DTMF Dialing]
Set Communications protocol to [DTMF Contact ID]
If panel has such option set [Contact ID Automatic Reporting Codes] Enable
PSTN communication events upon your needs
Open/Close/Alarm/Restore/Maintenance/Test Panel’s settings for two ways
ARM/DISARM synchronization.
Set Panel PGM to monitoring ARM status in level (steady) Mode Activation
event:[ ARM Area1 ] Deactivation Event : [ DISARM Area1 ] Mode: [Steady] NO/NC
depending of GTalarm2 input keyswitch settings.
In our example set to [NO] Set Panel Keyswitch to Momentary (Pulse) Mode
Zone Type : [Keyswitch Momentary] (Pulse)
Area Assigment: [Area 1] (Set AREA you want to control)
Keyswitch Action: [ARM/DISARM] Communicator’s data package protocol SIA
Ademco CONTACT ID is being supported (according to SIA DC-05 standard)
Telephone number and data transfer format DTMF (tone)
Two ways ARM/DISARM synchronization means USER able to control panel via
panel’s keyboard as well as remotely form GTCOM2
APP/WEB/SMS/iButton/RFID/Call. This means that the GTCOM2 APP will show the
same system status as keyboard of security panel.
HOW TO SET GTCOM2 & PRIMARY PANEL SYNCHRONIZATION By Panel’s PGM?
Go to SERA2> System Options> General System Options Set App ARM/ DISARM Synchr
mode to “By Panel PGM”
Set GTCOM2 keyswitch zone
Go to SERA2> Inputs/ Burglar Alarm Zones and set:
Keyswitch Zone Mode : [Level] (Steady)
Definition: [keyswitch ARM/DISARM] Type: [NC] Press “Write”
Set module PGM action on ARM/DISARM command from
APP/CALL/SMS/iButon/RFID
Go to SERA2> Outputs (PGM).
Out Definition: [Activate by ARM/DISARM Command] No: [1] (this is partition
number )
Mode: [Pulse] Timer: [2s] (this is PGM pulse time on ARM/DISARM command)
HOW TO SET GTCOM2 & PRIMARY PANEL SYNCHRONIZATION By Panel’s Events
A) do not need one wire from GTCOM2 input to Panel’s PGM Go to SERA2> System
Options> General System Options Set App ARM/ DISARM Synchr mode to “By Panel
Events”
Set module PGM action on ARM/DISARM command from
APP/CALL/SMS/iButon
Go to SERA2> Outputs (PGM)
Out Definition: [Activate by ARM/DISARM Command] No: [1] (this is partition
number)
Mode: [Pulse] Timer: [2s] (this is PGM pulse time on ARM/DISARM command)
B) Need to connect: TIP/RING GTCOM PGM -> Panel Keyswitch (Pulse mode)
GTCOM Keyswitch <- Panel PGM (Level Mode)
Go to SERA2> System Options> General System Options Set App ARM/ DISARM Synchr
mode to “By Panel Events” Set GTCOM2 keyswitch zone
Go to SERA2> Inputs> Burglar Alarm Zones and set:
Keyswitch Zone Mode : [Level] (Steady)
Definition: [keyswitch ARM/DISARM] Type: [NC] Press “Write”
Set module PGM action on ARM/DISARM command from
APP/CALL/SMS/iButon
Out Definition: [Activate by ARM/DISARM Command] No: [1] (this is partition
number )
Mode: [Pulse] Timer: [2s] (this is PGM pulse time on ARM/DISARM command)
Install Android app.
-
Scan QR code with your Android Phone: Or go to https://play.google.com
And find SeraNova app Or use web verion at: https://seranova.eu/login
https://play.google.com/store/apps/details?id=com.seranova.cloud&hl=en&gl=US -
Log in with your user name and password or register and create a new account.
-
If You don’t know IMEI Send IMEI requested SMS command to the number of the SIM card inserted into the controller. IMEI request SMS: INST000000 100 1 Or got to SERA2> System Options> System Info
-
Go to SYSTEMS, Choose Add new system and enter the controller Unique ID (IMEI) number. IMPORTANT: When adding thecommunicator to SeraNova app:
1. The Sera Cloud service must be turned on.
2. The power supply must be turned on.
3. Must be registered in to network. Default App Key: 123456.
„User Code to Control System“ must be the same as “Keypad code” in the Sera2> “User/ access control” Default 123456
ARM/ DISARM with SMS
User phone number must be the SERA2> Users/ Access control list Send SMS
message to the module: USER123456˽030˽ST USER – command from user commands
list 123456 – user’s password (default) ˽ – Space character 030- command code
˽ – Space character ST – Configuration array Change security system’s mode
(ARM/DISARM/STAY/SLEEP) 030= command code (Change security system’s mode
(ARM/DISARM/STAY/SLEEP) ST = Security system mode 0-DISARM, 1-ARM, 2-STAY,
3SLEEP Enter user phone number in the Sera2> Users/ Access control list.
How to test GTCOM2 & Primary Panel synchronization?
Go to SERA2> RT Testing & Monitoring> Hardware Press “Start Monitoring” button
Press I/O1 On/Off button See in Inputs (ADC values) Should change 1 > 0 or 0>1
Status of the primary panel should change Go to SERA2> RT Testing &
Monitoring> Security Alarm Panel/ Access The status of GTCOM2 module should
change You will see the same process in your smart phone. In mobile app.
References
- TOPKODAS - Security, Automation, Monitoring: Temperature, Humidity
- TOPKODAS - Security, Automation, Monitoring: Temperature, Humidity
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>