TOPKODAS PROGATE Cellular Gate Access Controller User Guide
- June 3, 2024
- TOPKODAS
Table of Contents
TOPKODAS PROGATE Cellular Gate Access Controller
Specifications
- Technology platform: LTE CAT-1 or GSM/GPRS/EDGE
- Administrators: up to 8 can receive SMS and Call Users database (Phones, iButton, RFID, Codes): up to 800
- Power supply: AC 10-24 V 50 Hz ~ 200 mA max / DC 10-30 V 200 mA max
- Current consumption in idle state w/o external devices connected: up to 50mA
- Number of inputs: 2
- Zone: NC, NO or EOL=5.6kΩ (settable)
- Analog: 0-30V (settable)
- Number of I/O input/output: 2
- Open Drain 24V/1A
- Zone: NC, NO or EOL=5.6kΩ (settable)
- Relay Output: 1A 30 V DC, 0.5A 125 V AC
- Wiegand interface: 26-bit Wiegand format 8-bit Keypad PIN/CODE format
- Maxim’s 1-Wire® interface: iButton Keys DS1990A; temperature sensors DS18b20
- Aosong 1-wire Humidity/Temperature Sensor AM23xx
- Buffer for unsent events: up to 3072 events
- Nonvolatile flash Event LOG: up to 3072 events
- Dimensions: 73x62x26mm
- Operating temperature range: -20…+55 °C
- Module weight: 70g
- Package weight: 90g
- Humidity: 0-90% RH @ 0… +40°C (0-90% RH @ +32… +104°F) (non-condensing)
LED indication
Name | Indication variations | Meaning |
---|
POWER
(green)
| Watchdog blinking, on
50ms,off for 1000ms
| The module is functioning.
Off| No power voltage.
__
__
__
NET (yellow)
| Lights continuously| Modem is registered
Flashes, remains lit for
50ms, turns off for 300ms
| Modem is being registered to the
network.
Blinking fast, 50ms on,
and off for 50ms
| PIN code of SIM card error. PIN
code request should be removed
Off| Modem failed to register to the
network.
__
DATA (red)
| Lights continuously| Module contains unsent reports to the user or to the
server.
Off| All reports has been send.
RELAY(blue)| On/Off| Relay state On/Off
Quick set up of the controller
-
Insert nano-SIM card. Turn off PIN code requests
-
Screw GSM antenna,
-
Connect power supply 10-30VDC
Note : the USB power supply can only be used for configuration. It is not sufficient to power the modem. -
Call to the module.
Note : The first one to call the controller will become the system administrator. Device will turn on the RELAY output for 2 seconds. The phone number will be stored in the module’s memory automatically. The caller will receive a greeting SMS with the IMEI of the module. At this moment all calls from different phone number will be rejected. The controller can be installed without any additional configuration if such operation mode is acceptable. -
Configuration and control methods:
SERA2 – configuration software via USB or internet remote https://www.topkodas.lt/Downloads/SERA2_Setup.exe
SERANOVA – Free WEB app https://seranova.eu/login SMS – configuration with INST commands.
Complete SMS commands can be found in full Installation & Programming manual Manual https://www.topkodas.lt/product/progate-4g
Add/Edit/Delete Users to receive SMS/DIAL
Using SMS commands:
Add/Edit User SMS/DIAL communication: INST000000˽001˽N#TEL#SMS#DIAL# 001=
command; N = user index 1-8; TEL = telephone number international format
without (+); SMS = notifications event filter; DIAL = event filter; #=
delimiter
Event filter from left to right 0-disabled; 1-enabled:
- Alarm/Restore (CID 100 group)
- System Open/Close (CID 400 group)
- System Troubles (CID 300 group)
- Sensor1-Sensor32 Alarm/Restore
- Test Events (CID 600 group)
- Other Events
- Input/Zone1 Alarm/Restore
- Input/Zone2 Alarm/Restore
- Input/Zone n etc.
e.g. INST000000˽001˽1#37066666666#0000000000#0000000000#
This example disable all SMS and DIAL notifications.
Delete SMS/DIAL user by index: INST000000˽002˽ID ID = user index number
from 1 to 8.
Add user to remote control output Arm/Disarm:
INST000000˽004˽ID#TEL#OUT#OPT#NAME# 004= command code (enter user‘s telephone
number for remote control via short call) ID = user index 1-800, TEL = user‘s
phone #; OUT= output number 1-32. 0-disabled OPT = 0 – disabled 1 – enabled,
Sequence from the left to the right 1. User Enabled 2. Enable Arm/Disarm
system by call NAME = User Name e.g.INST000000˽004˽1#37066666666#1#10#Jon#
Delete all user data by index:
INST000000˽006˽ID ID = user‘s index number from 001 to 800. Using SERA2
Configuration software via USB or internet:
Setting parameters using SERA2 software
With SERA2 software you can change the controller’s settings (if default
settings are not enough)
- Download the configuration software SERA2 from https://www.topkodas.lt/downloads/ and install it.
- Connect the controller to a computer using a mini USB cable.
- Launch the configuration software SERA2. The program will automatically recognize the connected device and will
- Automatically open the controller configuration window.
- Click Read to see current controller parameters.
Note : The button [Read] will make the program read and show the settings currently saved on the device. The [Write] button will save the settings to the flash memory. The button File> [Save] will save the configuration to file for later use. This allows to quickly configure multiple devices with the same settings. The button File> [Open] will allow to choose a configuration file and open saved settings. To revert to the default settings, go to Update FW without checking the Preserve settings checkbox.
SERANOVA app
With SERANOVA app users will be able to administrate users and control
remotely. They will also be able to see the system state and receive push
Notifications, all event messages. Free WEB SERANOVA app
https://seranova.eu/login Scan QR code and install SERANOVA app.
Login. New Customer? Please create an account.
SERA cloud service
To use the SERANOVA app or the SERA2 remote connection. The SERA cloud service
needs to be activated by using the SERA2 or SMS command e.g. INST000000˽010˽1.
By default this service is activated.
Imortant! If there is no data plan on your SIM card. [SERA
Cloud service] must be deactivated. Using SERA2 or SMS command:
INST000000˽010˽0 Otherwise the module will stop working due to a lost data
connection.
SMS command to set APN DATA/GPRS/LTE network settings
INST000000˽008˽APN#LOGIN#PSW#
e.g.INST000000˽008˽internet### where apn=’internet’;
Ways to get device IMEI (UID)
- First call to module. The caller will receive a greeting SMS with the IMEI of the module.
- By SMS sending command. INST000000˽100˽1
- Run SERA2 and device to USB. [SERA2> System Options> System Info]
Add new system to the app
- Enter the IMEI (UID)
- Enter App key. Default 123456.
- Enter user access code. Default 123456. Without a user access code, user unable to control system.
- Enter system SIM phone number
- Enter system name.
- Press [Save]
How to add additional system
A SERANOVA user can add an unlimited number of systems. Go to SYSTEMS> [Add
new system]
Add a new user
- Before adding a new user to the system. The new user must download the SERANOVA app and create an account
- System owner/admin goes to SERANOVA>Menu>Users> [Add new User]. Fill all required fields: email, user code, output, user permissions …
Enter a valid email address of a user who already has a SERANOVA account. The system will automatically be added to the user’s account.
How to add the System manually
The user must log in to SERANOVA account with the same email that the admin
added to user list. Then the admin has to tell PROGATE details IMEI, user
access code. And only then the user will be able to add the system to their
app see: 4.3 Add new system to the app.
Installation & wiring
Mounting types
Wall mounting. (No need to open enclosure!)
- Velcro stick- on adhesive fasteners
- DIN Rail mounting
- Flush mounting over electric wall box
Following the connecting diagram, connect the relay contact to the device you wish to control and connect the power supply: All wiring should be done with the power supply disconnected!
Wiring diagram for automatic gate opener
Usually the contacts you need to connect from gate control unit to the PROGATE
module are a certain input (x IN) and common terminal (COM).
The automatic gate has a gate state position output (OUT) that shows when the gates are closed and when they are open. The intermediate relay K1 is turned on when the gates are open and it activates the PROGATE IN1 input. The state of the PROGATE module’s IN1 input gives precise information about the state of the gates (when the gates are closed and when they are open).
Wiegand keypad & RFID card reader **wiring**
- Connect Wiegand keypad as shown in the Fig
- How to configure Wiegand keypad:
- Install SERA2 software. Device> PROGATE
- Connect the module to the computer via mini USB cable.
It is possible to enter RFID Keycard codes manually or automatically via SERA2 software of SMS messages as defined below.
A) Enter RFID Keycard codes manually.
In that case, you have to:
- Go to “Users& Remote Control” table. Enter RFID Keycard number and other required parameters
- Enter RFID Keycard codes for users.
- Select RFID Keycard action OUT/ARM/DISARM, etc.
- Write the configuration into the module by pressing “Write” icon
B) Enter RFID Keycard codes automatically via SERA2 software.
- Press [Learn iButtons/RFID mode] in: SERA2> System Options> General System Options. .
- Write configuration by pressing “Write” icon.
C) Enter RFID learning/ deleting mode by sending SMS message
If you need to enter RFID learning / deleting mode by sending SMS message, you
have to send:
INST000000˽063˽S
S = keys entering/deletion mode.
0 – Disable
1 – Keys learning mode,
2 – Keys deleting mode,
iButton Keys
Maxim-Dallas iButton keys (iButton DS1990A – 64 Bit ID)) can be used to control selected output or ARM/DISARM alarm system. Up to 800 iButton keys can be assigned to the system. iButton keys can be assigned in the same way as RFID. See:
Remote control
Control with phone call
The first one to call the controller will become the system administrator.
Call the number of the SIM card inserted into the controller. The controller
automatically rejects the call and turns on the RELAY output for 2 seconds and
will be the only one who can administer and control the controller with free
short call, SMS commands.
Control using SERANOVA app
- How to start SERANOVA app read paragraph 4 SERANOVA app
- Add an output widget and set the output parameters: name; pulse/level; icon; and other…
- If the gate is controlled by impulse. Select the input associated with the gate position sensor to reflect the actual state of the gate.
Control with SMS messages
Control the RELAY output with this SMS command:
Activate or deactivate selected output
USER123456˽021˽N#ST
021= command code (Activate or deactivate selected output N)
N = output number 1-32; ST= output mode: 0 – deactivated output, 1- activated
output
e.g. USER123456˽021˽1#1 Activate OUT1
Output pulse activation for the time interval
USER123456˽022˽N#TIME#
022= command code, N = output number 1-32; TIME = 0-999999 Time interval in
seconds for the output activation.
e.g. USER123456˽022˽2#5# Activate OUT2 for 5 seconds.
This Quick Start Guide provides only basic information about the device. For
more detailed information, please refer to the full manual: Installation &
Programming Manual
https://www.topkodas.lt/Downloads/media/Manuals/PROGATE_UM_EN.pdf
Documents / Resources
|
TOPKODAS PROGATE Cellular Gate Access
Controller
[pdf] User Guide
PROGATE Cellular Gate Access Controller, PROGATE, Cellular Gate Access
Controller, Gate Access Controller, Access Controller, Controller
---|---
|
TOPKODAS Progate Cellular Gate Access
Controller
[pdf] User Guide
Progate Cellular Gate Access Controller, Cellular Gate Access Controller, Gate
Access Controller, Access Controller, Controller
References
- PROGATE Cellular GSM Gate Opener GSM Access Gate Control
- TOPKODAS - Security, Automation, Monitoring: Temperature, Humidity
- Downloads - TOPKODAS
- Downloads - TOPKODAS
- SERA2 tool for configuration - TOPKODAS
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>