RUNZE RZ01 Peristaltic Pump User Manual

June 3, 2024
RUNZE

RUNZE RZ01 Peristaltic Pump

RUNZE RZ01 Peristaltic Pump-fig1

Product Introduction

Pump Outline and Installation Dimensions(unit: mm)

RUNZE RZ01 Peristaltic Pump-fig2

Naming Rules
The model parameters are as follows:

RUNZE RZ01 Peristaltic Pump-fig3

Product Introduction

Flow Curve Chart

RUNZE RZ01 Peristaltic Pump-fig4

Technical Parameters of Motor
  1. Motor Characteristics
Name Parameter
Rated Voltage 24V
Rated Current 1.1A
Max Output 10.1W
Motor step Angle 1.8°
Angle error 1.8°±0.09°
Input impedance 4.2Ω±0.42Ω
Work temperature -10℃~+50℃
Weight 350g
  1. Motor Wiring
    **** Port| Wire color
    ---|---
    A+| RED
    A-| YELLOW
    B+| BLUE
    B-| ORANGE
  2. Motor Reliability

No.

| ****

Test Item

| ****

Test Condition

| Reference Specifications
---|---|---|---


1

| Low temperature placement

(cold resistance)

| ****

Temperature:-40℃±3℃ Test time:96h

| ****

JIS C 60068-2-1

2| High temperature (heat resistance)| Temperature:85℃±2℃ Test time:96h| JIS C 60068-2-2



3

| High temperature and humidity (moisture resistance)| Temperature:60℃±2℃

(40℃±2℃) humidity:93%+2/-3% Test time:96h

| ****


JIS C 60068-2-3



4

| Hot and cold operation (temperature variation)| Temperature:Low-temperature test – 40℃±3℃1h

(Temperature change time: Within 5min) High Temperature Test:85%±2℃ 1h cycle index:25 times

| ****


JIS C 60068-2-14



5

| ****


Vibration Test

| Vibration range:10Hz~55Hz~10Hz Amplitude:1.5mm]

Direction of the vibration: X.Y.Z Time: 2h in each direction

| ****


JIS C 60068-2-6



6

| ****


DROP TEST

| 981 accelerated velocity m/s² half sinusoid Action time:6ms

Drop Direction:±X,±Y,±Z Drops times:3 times in each direction

| ****


JIS C 60068-2-27

  1. **Motor Dimension

RUNZE RZ01 Peristaltic Pump-fig5

**

Configuration of Pump Hose

Friendly Tip: the hose can be smeared with appropriate lubricating grease to extend its service life.

  • Step 1
    Open pump head lock downward

RUNZE RZ01 Peristaltic Pump-fig6

  • Step 2
    Remove the transparent pump head cover

RUNZE RZ01 Peristaltic Pump-fig7

  • Step 3
    Install the pump hose

  • Step 4
    Notice that the two ends of the pump hose are clamped on the pump head

  • Step 5
    Install pump head cover and close pump head lock upward

  • Step 6
    Installation Complete

RUNZE RZ01 Peristaltic Pump-fig11

 Technical Service

RUNZE RZ01 Peristaltic Pump-fig12

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

RUNZE User Manuals

Related Manuals