Preset Data Dump & Load Procedures

PA-1QG Analog 10 Band Programmable EQ for Guitar

Transferring preset data to another PA-1Q series unit

  1. Prepare a MIDI cable and connect it between the [MIDI OUT/THRU] terminal on the preset sending PA-1Q series unit and the [MIDI IN] terminal on the preset receiving PA-1Q series unit.
  2. On each PA-1Q series unit, turn on the power while holding down both the 【◀Cursor Key】 and 【Save】switches.
  3. The [LEVEL] display flashes “ snd”
  4. On the preset receiving PA-1Q series unit, turn the 【PARAMETER】encoder switch until the 【LEVEL】display shows “ rec”. Then, press the 【PARAMETER】encoder switch.
  5. When “ rec” on the display changes from flashing to lit, you are ready to transfer preset data.
  6. On the preset sending PA-1Q series unit, turn the 【PARAMETER】encoder switch until the 【LEVEL】 display shows “ snd”. Then, press the 【PARAMETER】encoder switch.
  7. On both the preset receiving and sending PA-1Q series units, the 【PRESET】display starts counting up from “00” to “99” and the unit will automatically reboot itself and show the firmware version, and the transfer will then be completed. This will take about 1 second on the sending side and 5 seconds on the receiving side.

Saving preset data to a personal computer/Sending preset data to PA-1Q series
1.Preparation of personal computer and MIDI interface:

  1. Prepare a Windows PC or Macintosh and a MIDI interface.
  2. Connect the personal computer to the MIDI interface.
  3. Download a MIDI interface driver and make the system ready for data transmission.

Do not connect the PA-1Q series unit to the MIDI interface at this step.
For setting up information of the MIDI interface, please refer to its manual.
NOTE: Please use a stable data transmissionable MIDI / USB interface cable for connecting a MIDI device to a PC.
2. Obtain MIDI software and install it in your personal computer:
For Macintosh, refer to page 3.
For Windows PC, refer to page 11.

For Macintosh

Preparation of MIDI software

  1. Download the freeware “SysEx Librarian” from http://snoize.com/SysExLibrarian/ and save it in a folder.

  2. Unzip the downloaded file and install the software.

  3. Start the SysEx Librarian.The following screen appears.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
1

  4. Setting up the SysEx Librarian:
    From the pulldown menu in the main window, select the MIDI interface to be used.(e.g. : When using the YAMAHA UX16 interface, “Port 1” is displayed as shown in the figure. The display differs depending on the interface, so please refer to the interface manual.)
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
2The interface list will not be shown if no MIDI interface is connected or the MIDI interface driver is not installed correctly. If the list is not shown, confirm whether the MIDI interface is connected correctly and the driver has been installed. The following screen appears when you select the interface to be used.

FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
3

=> Sending and saving the preset data from the PA-1Q series unit to your computer: refer to page 4.
=> Loading the saved preset data to the PA-1Q series unit: refer to page 8.

Sending and saving the preset data from the PA-1Q series unit to your computer

  1. Connect the MIDI interface’s “MIDI IN” terminal to the PA-1Q series’s [MIDI OUT/THRU] terminal.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
4

  2. Click “Record Many” displayed in the SysEx Librarian screen.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
5

  3. Click “Record Many.” The following screen appears.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
6

  4. While holding down both the 【◀Cursor Key】 and 【SAVE】 switches on the PA-1Q series, turn on the power to it.

  5. The【LEVEL】display shows “ snd” and flashes

  6. Press the 【PARAMETER】encoder.

  7. The 【PRESET】display starts counting up from “00” to “99.” The SysEx Librarian also shows counting up. When the count-up in the SysEx Librarian completes and the following screen appears, click “Done.”
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
7

  8. The received preset data is a file shown as “Untitled-**” in the SysEx Librarian’s SysEx File.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
8

  9. Select the received preset data. Select “Save As Sysex(.syx)” from the “File” menu of the SysEx Librarian to save the received preset.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
9

  10. Enter a name, select the storage location, and click “Save” to complete.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
10

Loading the saved preset data to the PA-1Q series unit

  1. Connect the MIDI interface’s “MIDI OUT” terminal to the PA-1Q series’s [MIDI IN] terminal.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
11

  2. While holding down both the 【◀Cursor Key】 and 【SAVE】switches on the PA-1Q series, turn on the power to it.

  3. The 【LEVEL】display shows “ snd” and flashes.

  4. Turn the 【PARAMETER】encoder switch until the 【LEVEL】display shows “ rec”. Then press the 【PARAMETER】encoder   switch.

  5. When “ rec” on the display changes from flashing to lit, you are ready to receive preset data of the PA-1Q series.

  6. Select “Add to Library” from the “File” menu of the SysEx Librarian.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
12

  7. Select the preset data to be written into the PA-1Q series and click “Open.”
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
13After selecting the file, the following message is displayed. Click “OK.”
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
14

  8. Select the preset data shown in the SysEx File list and click “Play” near the upper left corner of the screen.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
15

  9. The preset data is sent from the SysEx Librarian. The connected PA-1Q series unit’s 【PRESET】display starts counting up from “00” to “99” and the unit will automatically reboot itself and show the firmware version, and the transfer will then be completed.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
16

For Windows PC

Preparation of MIDI software

  1. From http://www.bome.com/products/sendsx, download the shareware “SendSx” which can be used for free for a limited period of time and save it in a folder.

  2. Unzip the downloaded file and install the software.

  3. Start the SendSx application. The following screen appears.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
17

  4. Setting up the SendSx application:
    From the application’s “MIDI Out” menu, select the MIDI interface to be used.
    The interface list will not be shown if no MIDI interface is connected or the MIDI interface driver is not installed correctly.
    If the list is not shown, confirm whether the MIDI interface is connected correctly and the driver has been installed.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
18The following screen appears when you select the interface to be used.

FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
19

=> Sending and saving the preset data from the PA-1Q series unit to your computer: refer to page 12.
=> Loading the saved preset data to the PA-1Q series unit: refer to page 15.

Sending and saving the preset data from the PA-1Q series unit to your computer

  1. Connect the MIDI interface’s “MIDI IN” terminal to the PA-1Q series’s [MIDI OUT/THRU] terminal.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
20

  2. While holding down both the 【◀Cursor Key】 and 【SAVE】 switches on the PA-1Q series, turn on the power to it.

  3. The【LEVEL】display shows and flashes “ snd.”

  4. Press the 【PARAMETER】encoder.

  5. The 【PRESET】display starts counting up from “00” to “99” The “MIDI IN” field in SendSx counts up.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
21 NOTE: If the SendSx application opens upon receiving a preset and the MIDI interface is correctly selected, then you do not have to operate SendSx.

  6. When SendSx completes receiving the preset data, the following screen is displayed.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
22

  7. Select “Save MIDI In As…” from the “File” menu.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
23

  8. Enter a filename. Select the storage location and click “Save” to complete.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
24

Loading the saved preset data to the PA-1Q series unit

  1. Connect the MIDI interface’s “MIDI OUT” terminal to the PA-1Q series’s [MIDI IN] terminal.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
25

  2. While holding down both the 【◀Cursor Key】 and 【SAVE】switches on the PA-1Q series, turn on the power to it.

  3. The 【LEVEL】display shows “ snd” and flashes.

  4. Turn the 【PARAMETER】encoder switch until the 【LEVEL】display shows “ rec”. Then press the 【PARAMETER】encoder   switch.

  5. When “ rec” on the display changes from flashing to lit, you are ready to receive preset data of the PA-1Q series.

  6. Select “Open” from the “File” menu of the SendSx application.
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
26

  7. From the folder, select the preset data to be written to the PA-1Q series and click “Open.”
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
27

  8. The “MIDI Out” field indicates character strings. Click “ snd ”
    FREE THE TONE PA-1QG Analog 10 Band Programmable EQ for Guitar - fig
28

  9. The preset data is sent from SendSX. The connected PA-1Q series unit’s 【PRESET】display starts counting up from “00” to “99” and the unit will automatically  reboot itself and show the firmware version, and the transfer will then be completed.

References