Overview of Update Steps

  1. Prepare a PC (Windows) or Mac (Macintosh) computer and setup your MIDI interface for data transmission.
  2. Download MIDI software (for Mac: SysEx Librarian, for Windows: SendSx) from the specified website and install it on your computer.
  3. Download the latest firmware from the Free The Toneʼs website.
  4. Connect the AMBI SPACE to the MIDI interface and send the firmware to the AMBI SPACE by using the installed MIDI software.
  5. After writing the data to the AMBI SPACE, press the MODE switch. This will cause the AMBI SPACE to reboot and complete the firmware update procedure. Note  that user preset contents will not be erased by this firmware update.

Firmware Update Procedures

Confirmation of Firmware Version

  1. Turn on the power to the AMBI SPACE.
  2. Confirm light-up times of the PRESET 1-4 LEDs above the SELECT footswitches.
  3. Turn off the power to the AMBI SPACE.
    After powering on, the PRESET 1-4 LEDs above the SELECT footswitches turn on and off from 1 to 4 in sequence. Then all of the PRESET 1-4 LEDs will turn on and off. The current firmware version can be checked by counting the number of light-up times. If the PRESET 1-4 LEDs do not illuminate, then the AMBI SPACE is  running with the ver. 1.0 firmware. If it is running with the ver. 1.1 firmware, it will reboot after all of the 1-4 LEDs illuminate once. The light- up times of the PRESET  1-4 LEDs for each firmware version are shown on the firmware download page.

Preparation of Computer and MDI Interface

  1. Prepare a PC (Windows) or Mac (Macintosh) computer and a MIDI interface.
  2. Connect the computer and the MIDI interface.
  3. Download the MIDI interface driver and make data transmission ready.
    At this phase the AMBI SPACE and the MIDI interface are not connected.
    Regarding setup procedures for your MIDI interface, please refer to its operation manual.
    (* Please use a stable data transmissionable MIDI / USB interface cable for connecting a MIDI device to a PC.)

Download of the Latest Firmware for AMBI SPACE
From the Free The Toneʼs website (http://www.freethetone.com/support/download.html), download the latest firmware file for the AMBI SPACE and unzip it.
Be sure to write down the name (ex: FIRMWARE) for the download destination folder in which you save the file.
NOTE: When downloading the file, you may sometimes encounter a message says that downloading AS-1R_FIRMWARE_V**.ZIP can damage your computer. In such a case, ignore the message and proceed to downloading.
Note that “**” denotes the version number.

Download and Installation of MIDI Software
Mac users: go to page 3.
Windows users: go to page 7.

For Mac Computer

  1. Preparation of MIDI Software
  1. Download the freeware “SysEx Librarian” from http://snoize.com/SysExLibrarian/ and save it in any folder.
  2. Unzip the downloaded ZIP file and install it.
  3. Start SysEx Librarian. The following screen will appear:
    FREE THE TONE AMBI SPACE Digital Reverb - Figure 1
  1. Configuration of SysEx Librarian
    Select the MIDI interface to be used from the main windowʼs pull-down menu.
    (e.g. : When using the YAMAHA UX16 interface, “Port 1” is displayed as shown in the figure. The display differs depending on the interface, so please refer to the  interface manual.) The list of interfaces will not be shown if the MIDI interface is not connected or the MIDI interface driver is not installed correctly. In such a case,  please check if the MIDI interface is connected correctly and the driver has been installed.
    FREE THE TONE AMBI SPACE Digital Reverb - Figure 2When you select the interface to be used, the screen changes to the following one:
    FREE THE TONE AMBI SPACE Digital Reverb - Figure 3

  2. Selection of Update File

  1. Click the “+” (or “Add…” on some versions) button located near the left bottom corner of the main window.
  2. Select the latest AMBI SPACE firmware file youʼve downloaded.
    After selecting the file, the following message appears. Click the “OK” button.
    FREE THE TONE AMBI SPACE Digital Reverb - Figure 4
    When the file is successfully read, its file name is listed as shown in the figure below. Click the file name to highlight. Now the file data in your Mac is ready to send.
    FREE THE TONE AMBI SPACE Digital Reverb - Figure 5
  1. Connecting AMBI SPACE and MIDI Interface
  1. Connect only the AMBI SPACEʼs MIDI IN terminal to the MIDI interfacesʼ MIDI OUT terminal.
  2. Turn on the power to the AMBI SPACE while holding down both the MODE and EDIT switches.
    The PRESET MODE and MANUAL MODE LEDs above the MODE switch and the EDIT LED above the EDIT switch illuminate.
    The AMBI SPACE is now ready to receive data.
    FREE THE TONE AMBI SPACE Digital Reverb - Figure 6
  1. Data Transmission
    Click the “Play” button near the left top corner of the SysEx Librarianʼs main screen.
    As soon as the data transmission starts as shown below, the PRESET 1 LED on the AMBI SPACE flashes.
    The PRESET 1-4 LEDs flash and illuminate steadily starting from the PRESET 1 LED. When all of the PRESET 1-4 LEDs illuminate, then the data writing process is  completed.
    CAUTION!
    Even when the indication on the SysEx Librarian shows that the data transfer is completed, the writing process on the AMBI SPACE is not completed until all of the  PRESET 1-4 LEDs turn on. Never turn off the power to the AMBI SPACE during the data transmission and writing process.
    FREE THE TONE AMBI SPACE Digital Reverb - Figure 7When all of the PRESET 1-4 LEDs illuminate, press the MODE switch to reboot and to be ready for operation. This completes the firmware update procedure.

For Windows Computer

  1. Preparation of MIDI Software
  1. Download the shareware “SendSx” from http://www.bome.com/products/sendsx and save it in any folder. You can use it free for a trial period.
  2. Unzip the downloaded ZIP file and install it to your computer.
  3. Start SendSx. The following screen will appear:
    FREE THE TONE AMBI SPACE Digital Reverb - Figure 8
  1. Configuration of SendSx
    Select the MIDI interface to be used from the “MIDI Out” menu.
    The list of interfaces will not be shown if the MIDI interface is not connected or the MIDI interface driver is not installed correctly. In such a case, please check if the  MIDI interface is connected correctly and the driver has been installed.
    FREE THE TONE AMBI SPACE Digital Reverb - Figure 9When you select the interface to be used, its name is shown in the lower half of the screen:
    FREE THE TONE AMBI SPACE Digital Reverb - Figure 10

  2. Selection of Update File

  1. Select “Open” from the “File” menu.
    FREE THE TONE AMBI SPACE Digital Reverb - Figure 112) In the file selection window, select the firmware file youʼve downloaded.
    When the file is read successfully, a screen that looks like the following will appear. Now your computer is ready for data transmission.
    FREE THE TONE AMBI SPACE Digital Reverb - Figure 12FREE THE TONE AMBI SPACE Digital Reverb - Figure
13
  1. Connecting AMBI SPACE and MIDI Interface
  1. Connect only the AMBI SPACEʼs MIDI IN terminal to the MIDI interfacesʼ MIDI OUT terminal.
  2. Turn on the power to the AMBI SPACE while holding down both the MODE and EDIT switches.
    The PRESET MODE and MANUAL MODE LEDs above the MODE switch and the EDIT LED above the EDIT switch illuminate.
    The AMBI SPACE is now ready to receive data.
    FREE THE TONE AMBI SPACE Digital Reverb - Figure 14
  1. Data Transmission
    Click the “Send(F4)” button located in the lower left section of the SendSxʼs main screen.
    As soon as the data transmission starts as shown below, the PRESET 1 LED on the AMBI SPACE flashes.
    The PRESET 1-4 LEDs flash and illuminate steadily starting from the PRESET 1 LED. When all of the PRESET 1-4 LEDs illuminate, then the data writing process is  completed.
    CAUTION!
    Even when the indication on the SendSX shows that the data transfer is completed, the writing process on the AMBI SPACE is not completed until all of the PRESET  1-4 LEDs turn on.
    Never turn off the power to the AMBI SPACE during the data transmission and writing process.
    FREE THE TONE AMBI SPACE Digital Reverb - Figure 15

When all of the PRESET 1-4 LEDs illuminate, press the MODE switch to reboot and to be ready for operation. This completes the firmware update procedure.