GREE FLEXX24HP230V1AH&BH Electric Heater Kit
Thank you for choosing our product.
Please read this Installation & Owner’s Manual carefully before operation and
retain it for future reference.
If you lose this Manual, please contact your local distributor visit
www.greecomcomfort.com/resources
now to download an file the electronic version.
ATTENTION INSTALLING PERSONNEL
- Prior to installation, thoroughly familiarize yourself with this Installation Manual. Observe all safety warnings. During installation or repair, caution is to be observed
- It is your responsibility to install the product safely and to educate the customer on its safe use
CAUTIONS
- ENSURE THAT ALL POWER IS DISCONNECTED PRIOR TO ATTEMPTING INSTALLATION OF THIS HEATER KIT. THERE MAY BE MORE THAN ONE DISCONNECT SERVICING THE UNIT.
- A MEANS OF STRAIN RELIEF AND CONDUCTOR PROTECTION MUST BE PROVIDED AT THE SUPPLY WIRE ENTRANCE INTO CABINET.
- USE COPPER CONDUCTORS ONLY
- INSTALLATION MUST FOLLOW NATIONAL ELECTRIC CODE AND OTHER APPLICABLE CODES
IF THIS APPLIANCE IS INSTALLED IN AN ENCLOSED AREA SUCH AS A GARAGE OR UTILITY ROOM WITH ANY CARBON MONOXIDE PRODUCING APPLIANCE, ENSURE THE AREA IS PROPERLY VENTILATED
REPAIRING INSTRUCTION
- Remove the front panel and upper access panel from the air handler.
- Disassemble the electrical box
- Remove the electrical box
- Disassemble the metal plate at the mounting hole of the electric heater
- Install the electric heater to the metal plate position which disassembles in step 4.(Notes: There are two holes circled below which are used to fasten the electric heater bracket during installation)
-
Install breaker (Notes: When installation, you need to lift up the buckle first, hold the breaker bracket and then put down the buckle to fix the breaker)
-
Connect the electric heater terminal
-
After installation, the schematic diagram is as follows:
- Install the electrical box back to the original position
- Install the front panel and upper panel back to the air handler. Electric heater installation is completed.
Electric Heater Kits
Model | Cooling capacity(ton) | Optional electric heater |
---|---|---|
FLEXX24,36HP230V1AH OR BH | 2.0 / 3.0 | FLEXXHTR5KW |
FLEXX24,36HP230V1AH OR BH | 2.0 / 3.0 | FLEXXHTR8KW |
FLEXX36,48,60HP230V1AH OR BH | 3.0 / 4.0 / 5.0 | FLEXXHTR10KW |
FLEXX48,60HP230V1AH OR BH | 4.0 / 5.0 | FLEXXHTR15KW |
FLEXX48,60HP230V1AH OR BH | 4.0 / 5.0 | FLEXXHTR20KW |